444 E UNIVERSAL HOLLYWOOD DR 91608

Certificate Information: 444 E UNIVERSAL HOLLYWOOD DR 91608

Application / Permit
19020-10000-02688
Plan Check / Job No.
B18LA27166
Group
Building
Type
Nonbldg-New
Sub-Type
Commercial
Primary Use
(23) Retaining Wall
Work Description
110' HIGH X 270' LENGTH RETAINING WALL PERMITTED ALONG W/ 18020-100000- WITH PERMANENT TIE BACKS.
Permit Issued
Issued on 4/22/2020
Issuing Office
Current Status
Issued on 4/22/2020

Permit Application Status History

Submitted 12/18/2018 APPLICANT
Assigned to Plan Check Engineer 1/18/2019 HERNAN ARREOLA
Corrections Issued 2/4/2019 HERNAN ARREOLA
Quality Review Completed 2/11/2019 BILL STUTSMAN
Building Plans Picked Up 2/11/2019 APPLICANT
Applicant returned to address corrections 3/27/2020 HERNAN ARREOLA
Plan Check Approved 4/22/2020 HERNAN ARREOLA
Issued 4/22/2020 APPLICANT

Permit Application Clearance Information

Work Adjacent to Public Way Cleared 4/14/2020 CHIU TAM
"Q" conditions Cleared 4/15/2020 DANALYNN DOMINGUEZ
Address approval Cleared 4/15/2020 CHIU TAM
Eng Process Fee Ord 176,300 Cleared 4/15/2020 CHIU TAM
Miscellaneous Cleared 4/15/2020 DANALYNN DOMINGUEZ
ZA Case Cleared 4/15/2020 DANALYNN DOMINGUEZ
ZA Case Cleared 4/15/2020 DANALYNN DOMINGUEZ
ZA Case Cleared 4/15/2020 DANALYNN DOMINGUEZ

Contact Information

Contractor Hathaway Dinwiddie Construction Company; Lic. No.: 729664-B 275 BATTERY STREET SUITE 300      SAN FRANCISCO, CA 941113330
Engineer Hodson,, Donald Joseph; Lic. No.: C78817 288 TAMARIND LANE      DANVILLE, CA 94526
Engineer Young,, Don Yuk-Man; Lic. No.: C35713 149 PASADENA AVE STE B      SOUTH PASADENA, CA 91030
Geologist Francuch,, Dean Gregory; Lic. No.: EG1842 9316 SOPHIA AVE      NORTH HILLS, CA 91343

Inspector Information

DEANDRE HOFFMAN, (818) 374-1182 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 10/29/2020 Approved ROBERT DAVIS
Pre-Inspection 11/4/2020 Approved ROBERT DAVIS
Deputy Grading 1/4/2021 Conditional Approval ROBERT DAVIS
Deputy Grading 1/5/2021 Approved ROBERT DAVIS
Deputy Grading 1/6/2021 Approved ROBERT DAVIS
Deputy Grading 1/7/2021 Approved ROBERT DAVIS
Deputy Grading 1/8/2021 Approved ROBERT DAVIS
Pre-Inspection 4/7/2021 Approved ROBERT DAVIS
Reinforced Concrete Frame 5/28/2021 Partial Approval ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 3/29/2023 Partial Approval ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 3/30/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 3/31/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/4/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/5/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/6/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/13/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/14/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/18/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/20/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/25/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/26/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 4/27/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 5/2/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 5/3/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 5/5/2023 Partial Approval ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 5/8/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 5/9/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 5/16/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 5/17/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 5/18/2023 Partial Approval ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 6/27/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 6/28/2023 Partial Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 7/19/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 7/20/2023 Partial Approval ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 7/21/2023 Not Ready for Inspection ROBERT DAVIS
Excavation/Setback/Form/Re-Bar 8/10/2023 Partial Approval JOHN KITCKO
Excavation/Setback/Form/Re-Bar 8/11/2023 Not Ready for Inspection JOHN KITCKO
Excavation/Setback/Form/Re-Bar 8/14/2023 Partial Approval JOHN KITCKO
Footing/Foundation/Slab 7/8/2024 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 7/9/2024 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 7/10/2024 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 7/11/2024 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 7/22/2024 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 7/23/2024 Not Ready for Inspection ROBERT DAVIS
Footing/Foundation/Slab 8/2/2024 Partial Approval ROBERT DAVIS
Footing/Foundation/Slab 8/5/2024 Not Ready for Inspection ROBERT DAVIS
Footing/Foundation/Slab 8/15/2024 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 8/23/2024 Partial Approval JOHN KITCKO
Footing/Foundation/Slab 8/27/2024 Not Ready for Inspection ROBERT DAVIS
Deputy Steel/Welding 1/7/2025 Conditional Approval JOHN KITCKO
Deputy Steel/Welding 1/8/2025 Conditional Approval JOHN KITCKO
Deputy Steel/Welding 1/9/2025 Approved JOHN KITCKO
Deputy Steel/Welding 1/10/2025 Conditional Approval JOHN KITCKO
Deputy Steel/Welding 1/13/2025 Conditional Approval JOHN KITCKO
Footing/Foundation/Slab 2/13/2025 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 3/4/2025 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 4/7/2025 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 4/8/2025 Partial Inspection JOHN KITCKO
Footing/Foundation/Slab 4/9/2025 Not Ready for Inspection JOHN KITCKO
Deputy Reinf. Concrete 6/18/2025 Approved JOHN KITCKO
Deputy Reinf. Concrete 6/20/2025 Conditional Approval JOHN KITCKO
Deputy Reinf. Concrete 6/25/2025 Approved JOHN KITCKO