1048 S RIDGELEY DR 90019

Certificate Information: 1048 S RIDGELEY DR 90019

Application / Permit
19016-30000-40758
Plan Check / Job No.
B19WL07174
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
CONVERSION OF (E) GARAGE AT THE REAR OF THE LOT INTO AN ADU PER AB494 & SB229.
Permit Issued
Issued on 3/10/2020
Issuing Office
West Los Angeles
Current Status
CofO Issued on 2/23/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 12/20/2019 APPLICANT
Assigned to Plan Check Engineer 12/23/2019 JAHANSHAH POURHASSAN
Corrections Issued 1/6/2020 JAHANSHAH POURHASSAN
Building Plans Picked Up 1/9/2020 APPLICANT
Applicant returned to address corrections 1/10/2020 KAVIAN REFAHI
Plan Check Approved 1/29/2020 ALFREDO JARA
Issued 3/10/2020 LADBS
CofO in Progress 12/18/2020 STUART CHAPMAN
Permit Finaled 2/23/2021 DEROLD HAUFF
CofO Issued 2/23/2021 DEROLD HAUFF
Permit Finaled 2/23/2021 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 1/10/2020 ANTHONY MAINEZ
Eng Process Fee Ord 176,300 Cleared 1/10/2020 ANTHONY MAINEZ
Sewer availability Cleared 1/10/2020 ANTHONY MAINEZ
HPOZ Cleared 1/13/2020 MICAELA TORRES-GIL
Construction near power lines Cleared 1/28/2020 RIDWAN HARDY

Contact Information

Contractor Furer Construction Inc; Lic. No.: 988604-B 3133 ROBERTS AVE      CULVER CITY, CA 90232
Engineer Bryson,, Michael Butler; Lic. No.: S4979 285 W 6TH ST 508      SAN PEDRO, CA 90731
Engineer Plouff,, Kacie Allison; Lic. No.: L9013 27821 FREMONT COURT 6      VALENCIA, CA 91355

Inspector Information

RONNIE MINDANAO, (213) 202-3252 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 9/21/2020 Approved ARTHUR SARGSYAN
METHANE-Rough 9/21/2020 Approved ARTHUR SARGSYAN
Underground Mechanical 9/21/2020 Approved ARTHUR SARGSYAN
Footing/Foundation/Slab 10/2/2020 Conditional Approval JOSEPH MCGARRY
PLUMBING-Rough 10/2/2020 Partial Approval JOSEPH MCGARRY
Footing/Foundation/Slab 10/7/2020 Approved ARTHUR SARGSYAN
BUILDING-Rough-Frame 10/16/2020 Partial Approval ARTHUR SARGSYAN
PLUMBING-Rough 10/16/2020 Approved ARTHUR SARGSYAN
ELECTRICAL-Rough 10/21/2020 Approved ARTHUR SARGSYAN
HVAC-Rough 10/21/2020 Approved ARTHUR SARGSYAN
BUILDING-Rough-Frame 10/29/2020 Approved ARTHUR SARGSYAN
Insulation 10/29/2020 Approved ARTHUR SARGSYAN
Interior/Exterior Lathing 10/29/2020 Approved ARTHUR SARGSYAN
Shower Pan 10/29/2020 Approved ARTHUR SARGSYAN
Drywall Nailing 11/5/2020 Not Ready for Inspection CHRIS CHRISTENSEN
BUILDING-Rough-Frame 12/2/2020 Approved DAVID CHAN
ELECTRICAL-Rough 12/2/2020 Approved DAVID CHAN
Final 12/2/2020 Not Ready for Inspection DAVID CHAN
HVAC-Rough 12/2/2020 Approved DAVID CHAN
PLUMBING-Rough 12/2/2020 Approved DAVID CHAN
SGSOV-Seismic Gas S/O Valve 12/2/2020 SGSOV Approved DAVID CHAN
Smoke Detectors 12/2/2020 Approved DAVID CHAN
Final 12/9/2020 Conditional Approval STUART CHAPMAN