4908-4910 N BEEMAN AVE 91607

Certificate Information: 4908-4910 N BEEMAN AVE 91607

Application / Permit
19016-20000-34565
Plan Check / Job No.
B19VN18571
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
CONVERT EX ATT 2-CAR GARAGE & LAUNDRY ROOM (54 SF) INTO ACCESSORY DWELLING UNIT PER AB 494 AND SB 229. THIS PERMIT TO INCLUDE REMODEL OF TWO EX BEDRMS & ONE EX BATHRM, POR OF EX LIVING RM INTO NEW LAUNDRY RM & CLOSET PER PLAN. ADDN TO EXTEND EXISTING FRONT PORCH.
Permit Issued
Issued on 1/29/2020
Issuing Office
Valley
Current Status
Issued on 1/29/2020
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 10/28/2019 APPLICANT
Assigned to Plan Check Engineer 10/29/2019 HAYATO TSUCHIYA
Corrections Issued 10/30/2019 HAYATO TSUCHIYA
Building Plans Picked Up 10/30/2019 APPLICANT
Plan Check Approved 1/28/2020 HAYATO TSUCHIYA
Issued 1/29/2020 LADBS

Permit Application Clearance Information

Miscellaneous Cleared 11/21/2019 HERMINIGILDO AGUSTIN
Address approval Cleared 11/26/2019 GUILLERMO PETRA
Sewer availability Cleared 11/26/2019 GUILLERMO PETRA
Eng Process Fee Ord 176,300 Cleared 12/11/2019 ADRIAN CASTRO
Specific Plan Cleared 12/12/2019 OLGA AYALA
Permit Cleared 1/27/2020 LEE GUILBEAUX

Contact Information

Engineer Mayorga,, Jose Aguinaldo; Lic. No.: C50322 20457 OREY PL      WINNETKA, CA 91306

Inspector Information

WAYNE REGESTER, (818) 374-1164 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 7/16/2020 Partial Approval BRENDAN LOONEY
PLUMBING-Rough 7/16/2020 Partial Approval BRENDAN LOONEY
PLUMBING-Rough 8/5/2020 Corrections Issued BRENDAN LOONEY
ELECTRICAL-Rough 8/13/2020 Corrections Issued BRENDAN LOONEY
PLUMBING-Rough 8/13/2020 Approved BRENDAN LOONEY
Wood Frame 8/13/2020 Corrections Issued BRENDAN LOONEY
BUILDING-Rough-Frame 8/20/2020 Partial Approval BRENDAN LOONEY
ELECTRICAL-Rough 8/20/2020 Partial Approval BRENDAN LOONEY
Green Building Rough 8/20/2020 Not Ready for Inspection BRENDAN LOONEY
Insulation 8/26/2020 Approved BRENDAN LOONEY
Floor/Roof Diaphrgm/Shear Wall 9/3/2020 Not Ready for Inspection BRENDAN LOONEY
Floor/Roof Diaphrgm/Shear Wall 9/10/2020 Approved BRENDAN LOONEY
Interior/Exterior Lathing 9/10/2020 Partial Approval BRENDAN LOONEY
Drywall Nailing 9/17/2020 Approved BRENDAN LOONEY
Green Building Rough 9/17/2020 Approved BRENDAN LOONEY
Interior/Exterior Lathing 9/17/2020 Approved BRENDAN LOONEY
Sewer 10/30/2020 Corrections Issued BRENDAN LOONEY
Underground Mechanical 11/14/2020 Approved DANIEL ORRANTE
BUILDING-Rough-Frame 4/26/2021 Approved RICHARD DOCKUS
Final 4/26/2021 Corrections Issued RICHARD DOCKUS
Green Building Final 4/26/2021 Approved RICHARD DOCKUS
SGSOV-Seismic Gas S/O Valve 4/26/2021 SGSOV Not Ready RICHARD DOCKUS
Smoke Detectors 4/26/2021 Approved RICHARD DOCKUS
PLUMBING-Rough 5/18/2021 Not Ready for Inspection RICHARD DOCKUS
SGSOV-Seismic Gas S/O Valve 5/18/2021 SGSOV Not Ready RICHARD DOCKUS
Insulation 5/20/2021 Approved RICHARD DOCKUS
Interior/Exterior Lathing 5/26/2021 Partial Approval RICHARD DOCKUS
Final 8/30/2021 Corrections Issued CHRISTOPHE COCHRAN
SGSOV-Seismic Gas S/O Valve 8/30/2021 SGSOV Approved CHRISTOPHE COCHRAN
ELECTRICAL-Rough 9/30/2021 Approved CHRISTOPHE COCHRAN
Footing/Foundation/Slab 9/30/2021 Approved CHRISTOPHE COCHRAN
PLUMBING-Rough 9/30/2021 Approved CHRISTOPHE COCHRAN
BUILDING-Rough-Frame 10/4/2021 Approved CHRISTOPHE COCHRAN