3982 S INGLEWOOD BLVD 90066
Certificate Information: 3982 S INGLEWOOD BLVD 90066
- Application / Permit
- 19016-10000-39024
- Plan Check / Job No.
- B19LA25784
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT PER LABC CHAPTER 93. INSTALL STEEL CANTILEVER COLUMNS.
- Permit Issued
- Issued on 3/5/2020
- Issuing Office
- Metro
- Current Status
- CofC Issued on 10/2/2020
Permit Application Status History
| Submitted | 12/10/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 12/18/2019 | MANUEL MONTUFAR |
| Corrections Issued | 12/26/2019 | MANUEL MONTUFAR |
| Quality Review Completed | 1/6/2020 | HANS SANTIAGO |
| Plan Check Approved | 1/13/2020 | MANUEL MONTUFAR |
| Issued | 3/5/2020 | LADBS |
| OK for CofC | 9/22/2020 | GRANT WOODS |
| CofC Issued | 10/2/2020 | TED RIES |
Permit Application Clearance Information
| Construction near power lines | Cleared | 1/9/2020 | TORI CHEN |
| Construction within easement | Cleared | 1/9/2020 | TORI CHEN |
| Tenant Habitability Plan | Cleared | 3/5/2020 | STEVEN HOFSTAD |
Contact Information
| Contractor | Retrofitting360 Inc; Lic. No.: 1039226-B | 19562 VENTURA BLVD# 230 TARZANA, CA 91356 |
| Engineer | Ni,, Zhang Yuan; Lic. No.: C68149 | 743 S SIERRA VISTA AVE C ALHAMBRA, CA 91801 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 5/14/2020 | Approved | ALAN NOVAK |
| Pre-Inspection | 5/14/2020 | Approved | ALAN NOVAK |
| Reinforced Concrete Frame | 7/16/2020 | Not Ready for Inspection | ALAN NOVAK |
| Structural Steel Frame | 7/16/2020 | No Access for Inspection | ALAN NOVAK |
| Wood Frame | 7/16/2020 | Not Ready for Inspection | ALAN NOVAK |
| Deputy Steel/Welding | 7/21/2020 | Conditional Approval | GRANT WOODS |
| Reinforced Concrete Frame | 7/23/2020 | Not Ready for Inspection | GRANT WOODS |
| Structural Steel Frame | 7/23/2020 | Partial Inspection | GRANT WOODS |
| Wood Frame | 7/23/2020 | Approved | GRANT WOODS |
| Footing/Foundation/Slab | 8/19/2020 | Partial Inspection | GRANT WOODS |
| Structural Steel Frame | 8/19/2020 | Approved | GRANT WOODS |
| Wood Frame | 8/19/2020 | Partial Inspection | GRANT WOODS |
| Interior/Exterior Lathing | 8/26/2020 | Approved | GRANT WOODS |
| Final | 9/22/2020 | OK for CofC | GRANT WOODS |
| SGSOV-Seismic Gas S/O Valve | 9/22/2020 | SGSOV Approved | GRANT WOODS |
| Smoke Detectors | 9/22/2020 | Approved | GRANT WOODS |