7248 N VASSAR AVE 91303
Certificate Information: 7248 N VASSAR AVE 91303
- Application / Permit
- 19016-10000-37062
- Plan Check / Job No.
- B19LA24448
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT PER LABC CHAPTER 93. INSTALL STEEL MOMENT FRAME AND PLYWOOD SHEAR WALL.
- Permit Issued
- Issued on 2/22/2021
- Issuing Office
- Current Status
- CofC Issued on 8/11/2021
Permit Application Status History
| Submitted | 11/15/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 12/11/2019 | ALBERT SERVIN |
| Corrections Issued | 12/18/2019 | ALBERT SERVIN |
| Quality Review Completed | 12/20/2019 | SAI KHUM |
| Building Plans Picked Up | 1/22/2020 | APPLICANT |
| Plan Check Approved | 3/5/2020 | ALBERT SERVIN |
| Issued | 2/22/2021 | APPLICANT |
| OK for CofC | 6/15/2021 | KENNETH ROBERTS |
| CofC Issued | 8/11/2021 | KENNETH ROBERTS |
Permit Application Clearance Information
| Supp. Use District POD/CDO/TDO | Cleared | 3/5/2020 | SARAHI ORTEGA |
| Tenant Habitability Plan | Cleared | 2/11/2021 | RICHARD BRINSON |
Contact Information
| Contractor | Quakestrong; Lic. No.: 1037437-B | 1213 LA BREA AVENUE LOS ANGELES, CA 90019 |
| Engineer | Cox,, Steven Jeffrey; Lic. No.: C48940 | 130 MAGELLAN ST THOUSAND OAKS, CA 91360 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 3/30/2021 | Partial Inspection | DANIEL VARNUM |
| Deputy Drilled-In Anchors | 4/30/2021 | Conditional Approval | DANIEL VARNUM |
| Footing/Foundation/Slab | 5/4/2021 | Approved | DANIEL VARNUM |
| Structural Steel Frame | 5/4/2021 | Approved | DANIEL VARNUM |
| Wood Frame | 5/4/2021 | Approved | DANIEL VARNUM |
| Deputy Reinf. Concrete | 5/5/2021 | Conditional Approval | KENNETH ROBERTS |
| Deputy Wood Construction | 5/6/2021 | Conditional Approval | DANIEL VARNUM |
| Interior/Exterior Lathing | 5/12/2021 | Approved | DANIEL VARNUM |
| Final | 5/26/2021 | Partial Approval | DANIEL VARNUM |
| SGSOV-Seismic Gas S/O Valve | 5/26/2021 | SGSOV Approved | DANIEL VARNUM |
| Smoke Detectors | 5/26/2021 | Approved | DANIEL VARNUM |
| Final | 6/15/2021 | OK for CofC | KENNETH ROBERTS |