3017 W 2ND ST 90057
Certificate Information: 3017 W 2ND ST 90057
- Application / Permit
- 19016-10000-33284
- Plan Check / Job No.
- B19LA22060
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CHAPTER 93. REMOVE TWO EXISTING COLUMNS AND INSTALL TWO (N) SCCS.
- Permit Issued
- Issued on 4/3/2020
- Issuing Office
- Metro
- Current Status
- CofC Issued on 6/7/2021
Permit Application Status History
| Submitted | 10/17/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 11/20/2019 | JOHN FRANCIA |
| Corrections Issued | 11/25/2019 | JOHN FRANCIA |
| Quality Review Completed | 12/1/2019 | HANS SANTIAGO |
| Building Plans Picked Up | 12/5/2019 | APPLICANT |
| Plan Check Approved | 12/26/2019 | JOHN FRANCIA |
| Issued | 4/3/2020 | LADBS |
| OK for CofC | 5/13/2021 | DARRYL ARNOLD |
| OK for CofC | 6/3/2021 | DARRYL ARNOLD |
| CofC Issued | 6/7/2021 | ERNESTO CORRAL |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 3/13/2020 | MICHAEL SOTO |
Contact Information
| Contractor | Cal Retrofit; Lic. No.: 1022167-B | 6900 CANBY AVE #108 RESEDA, CA 91335 |
| Engineer | Zohrevand,, Pedram; Lic. No.: C82328 | 21201 KITTRIDGE ST APT 9105 WOODLAND HILLS, CA 91303 |
Inspector Information
| DARRYL ARNOLD, (213) 482-0341 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 9/8/2020 | Conditional Approval | DARRYL ARNOLD |
| Wood Frame | 11/19/2020 | Partial Inspection | DARRYL ARNOLD |
| Deputy Other (see comments) | 3/22/2021 | Conditional Approval | DARRYL ARNOLD |
| Footing/Foundation/Slab | 3/23/2021 | Approved | DARRYL ARNOLD |
| Deputy Reinf. Concrete | 3/24/2021 | Conditional Approval | JONATHAN QUACH |
| Deputy Other (see comments) | 3/25/2021 | Conditional Approval | DARRYL ARNOLD |
| Structural Steel Frame | 3/31/2021 | Approved | DARRYL ARNOLD |
| Wood Frame | 3/31/2021 | Approved | DARRYL ARNOLD |
| Wood Frame | 4/14/2021 | Corrections Issued | MARK FERRARI |
| Wood Frame | 4/21/2021 | Not Ready for Inspection | DARRYL ARNOLD |
| Interior/Exterior Lathing | 5/3/2021 | Approved | JONATHAN QUACH |
| Final | 5/13/2021 | OK for CofC | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 5/13/2021 | SGSOV Approved | DARRYL ARNOLD |
| Smoke Detectors | 5/13/2021 | Corrections Issued | DARRYL ARNOLD |
| Final | 6/3/2021 | OK for CofC | DARRYL ARNOLD |
| Smoke Detectors | 6/3/2021 | Approved | DARRYL ARNOLD |