4650 W SUNSET BLVD 90027
Certificate Information: 4650 W SUNSET BLVD 90027
- Application / Permit
- 19016-10000-33205
- Plan Check / Job No.
- B19LA21997
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Commercial
- Primary Use
- (13) Office
- Work Description
- GROUP B OCCUPANCY, 2,183 SF TENANT IMPROVEMENT AND STORAGE RACK INSTALLATION FOR AQUATICS RESEARCH LOCATED ON THE GROUND FLOOR OF THE SMITH RESEARCH TOWER IN THE CHILDREN'S HOSPITAL LOS ANGELES CAMPUS. (NOT A HOSPITAL BLDG)
- Permit Issued
- Issued on 1/24/2020
- Issuing Office
- Metro
- Current Status
- Permit Finaled on 9/2/2020
Permit Application Status History
| Submitted | 10/16/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 10/24/2019 | SINA KHOSRAVI |
| Corrections Issued | 11/1/2019 | ZAW HAN |
| Disabled Access Plans Picked Up | 11/14/2019 | APPLICANT |
| Quality Review Completed | 11/18/2019 | HERNAN ARREOLA |
| Building Plans Picked Up | 11/20/2019 | APPLICANT |
| Applicant returned to address corrections | 12/18/2019 | ZAW HAN |
| Plan Check Approved | 1/23/2020 | ZAW HAN |
| Issued | 1/24/2020 | LADBS |
| Permit Finaled | 9/2/2020 | EDWIN GREGORYONA |
Permit Application Clearance Information
| DAS Clearance | Cleared | 12/30/2019 | ZAW HAN |
Contact Information
| Architect | Cervantes,, Gabriel Ruben; Lic. No.: C28842 | 907 N CORDOVA STREET BURBANK, CA 91505 |
| Contractor | Pacific National Group; Lic. No.: 188629-B | 2392 SOUTH BATEMAN AVENUE IRWINDALE, CA 910103312 |
| Engineer | Hershberg,, Mark Aaron; Lic. No.: S5078 | 6080 CENTER DR STE 300 LOS ANGELES, CA 90045 |
Inspector Information
| TIMOTHY POWELL, (213) 482-0360 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Light Gage Steel Frame | 2/5/2020 | Partial Approval | EDWIN GREGORYONA |
| Deputy Drilled-In Anchors | 2/12/2020 | Partial Approval | EDWIN GREGORYONA |
| Deputy Drilled-In Anchors | 2/14/2020 | Partial Approval | EDWIN GREGORYONA |
| Excavation/Setback/Form/Re-Bar | 2/14/2020 | Approved | EDWIN GREGORYONA |
| Footing/Foundation/Slab | 2/14/2020 | Approved | EDWIN GREGORYONA |
| Drywall Nailing | 2/21/2020 | Partial Approval | EDWIN GREGORYONA |
| Light Gage Steel Frame | 2/21/2020 | Approved | EDWIN GREGORYONA |
| Deputy Drilled-In Anchors | 4/21/2020 | Partial Approval | EDWIN GREGORYONA |
| T-Bar Ceiling | 7/24/2020 | Approved | RUSSELL BONVOULOIR |
| Deputy Drilled-In Anchors | 7/28/2020 | Partial Approval | EDWIN GREGORYONA |
| SGSOV-Seismic Gas S/O Valve | 8/28/2020 | SGSOV Not Ready | EDWIN GREGORYONA |
| Final | 9/2/2020 | Permit Finaled | EDWIN GREGORYONA |
| SGSOV-Seismic Gas S/O Valve | 9/2/2020 | SGSOV Approved | EDWIN GREGORYONA |
| Smoke Detectors | 9/2/2020 | Approved | EDWIN GREGORYONA |