11415 W CALVERT ST 91606
Certificate Information: 11415 W CALVERT ST 91606
- Application / Permit
- 19016-10000-32850
- Plan Check / Job No.
- B19LA21793
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT PER LABC CHAPTER 93. INSTALL PLYWOOD SHEARWALLS AND HFX PANELS.
- Permit Issued
- Issued on 2/19/2020
- Issuing Office
- Metro
- Current Status
- CofC Issued on 5/9/2020
Permit Application Status History
| Submitted | 10/21/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 11/14/2019 | MANUEL MONTUFAR |
| Corrections Issued | 11/18/2019 | MANUEL MONTUFAR |
| Quality Review Completed | 11/27/2019 | HANS SANTIAGO |
| Plan Check Approved | 1/22/2020 | MANUEL MONTUFAR |
| Issued | 2/19/2020 | LADBS |
| OK for CofC | 5/8/2020 | MARK FERRARI |
| CofC Issued | 5/9/2020 | DAVID TSAU |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 1/22/2020 | MICHAEL SOTO |
Contact Information
| Contractor | Xebec Construction; Lic. No.: 638225-B | 1460 7TH STREET SUITE 203 SANTA MONICA, CA 90401 |
| Engineer | Namdar,, Mansour Tom; Lic. No.: NA2976 | , |
| Engineer | Namdar,, Mansour Tom; Lic. No.: S2976 | 16867 SEVERO PLACE ENCINO, CA 91436 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Floor/Roof Diaphrgm/Shear Wall | 3/18/2020 | Approved | HAMID PISHEHVAR |
| Pre-Inspection | 3/18/2020 | Approved | HAMID PISHEHVAR |
| Footing/Foundation/Slab | 3/20/2020 | Approved | DANIEL VARNUM |
| Deputy Reinf. Concrete | 3/24/2020 | Conditional Approval | FRED WOHLFARTH |
| Deputy Wood Construction | 3/31/2020 | Conditional Approval | DAVID BURKHEAD |
| Floor/Roof Diaphrgm/Shear Wall | 4/3/2020 | Approved | DANIEL VARNUM |
| Wood Frame | 4/3/2020 | Approved | DANIEL VARNUM |
| Interior/Exterior Lathing | 4/17/2020 | Approved | JOE VELASQUEZ |
| Final | 4/29/2020 | Not Ready for Inspection | JOE VELASQUEZ |
| SGSOV-Seismic Gas S/O Valve | 4/29/2020 | SGSOV Not Ready | JOE VELASQUEZ |
| Smoke Detectors | 4/29/2020 | Not Ready for Inspection | JOE VELASQUEZ |
| Final | 5/8/2020 | OK for CofC | MARK FERRARI |
| SGSOV-Seismic Gas S/O Valve | 5/8/2020 | SGSOV Approved | MARK FERRARI |
| Smoke Detectors | 5/8/2020 | Approved | MARK FERRARI |