12415 W ARCHWOOD ST 91606

Certificate Information: 12415 W ARCHWOOD ST 91606

Application / Permit
19016-10000-31717
Plan Check / Job No.
B19LA21073
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Soft-Story seismic retrofit per LABC Chapter 93: Install new (1) STEEL SPECIAL CANTILEVER COLUMN
Permit Issued
Issued on 8/25/2020
Issuing Office
Current Status
CofC Issued on 8/17/2023

Permit Application Status History

Submitted 10/3/2019 APPLICANT
Assigned to Plan Check Engineer 11/14/2019 DANIEL SANJUAN
Corrections Issued 11/27/2019 DANIEL SANJUAN
Quality Review Completed 12/2/2019 HANS SANTIAGO
Plan Check Approved 6/11/2020 DANIEL SANJUAN
Issued 8/25/2020 APPLICANT
OK for CofC 8/10/2023 KENNETH ROBERTS
CofC Issued 8/17/2023 KENNETH ROBERTS

Permit Application Clearance Information

Housing rent stabilization Cleared 8/17/2020 STEVEN HOFSTAD

Contact Information

Contractor American Retrofitters Corp; Lic. No.: 1020382-B 15643 SHERMAN WAY STE 220      VAN NUYS, CA 91406
Engineer Kazarians,, Ardashes; Lic. No.: C36687 1528 CANADA BLVD STE 206      GLENDALE, CA 91208

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 9/21/2020 Not Ready for Inspection JOE VELASQUEZ
Deputy Steel/Welding 9/30/2020 No Access for Inspection JOE VELASQUEZ
Footing/Foundation/Slab 10/16/2020 Approved EDWIN GREGORYONA
Deputy Drilled-In Anchors 10/19/2020 Partial Approval EDWIN GREGORYONA
Deputy Reinf. Concrete 10/19/2020 Partial Approval EDWIN GREGORYONA
Deputy Reinf. Concrete 10/20/2020 Partial Approval EDWIN GREGORYONA
Structural Steel Frame 10/20/2020 Approved EDWIN GREGORYONA
Wood Frame 10/20/2020 Approved EDWIN GREGORYONA
Interior/Exterior Lathing 10/27/2020 Approved EDWIN GREGORYONA
Final 6/10/2021 Not Ready for Inspection JOE VELASQUEZ
SGSOV-Seismic Gas S/O Valve 6/10/2021 SGSOV Not Ready JOE VELASQUEZ
Smoke Detectors 6/10/2021 Not Ready for Inspection JOE VELASQUEZ
Final 6/23/2023 Corrections Issued KENNETH ROBERTS
SGSOV-Seismic Gas S/O Valve 6/23/2023 SGSOV Not Ready KENNETH ROBERTS
Smoke Detectors 6/23/2023 Approved KENNETH ROBERTS
Final 8/10/2023 OK for CofC KENNETH ROBERTS
SGSOV-Seismic Gas S/O Valve 8/10/2023 SGSOV Approved KENNETH ROBERTS