4412 W LOCKWOOD AVE 90029
Certificate Information: 4412 W LOCKWOOD AVE 90029
- Application / Permit
- 19016-10000-29312
- Plan Check / Job No.
- B19LA19532
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- Eplan 1030 :: Soft-Story seismic retrofit per LABC Chapter 93: Install new moment frame.
- Permit Issued
- Issued on 6/22/2020
- Issuing Office
- Current Status
- CofC Issued on 4/13/2021
Permit Application Status History
| Submitted | 9/15/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 10/30/2019 | VARAND SARKISIAN |
| Corrections Issued | 11/4/2019 | VARAND SARKISIAN |
| Quality Review Completed | 11/7/2019 | HANS SANTIAGO |
| Plan Check Approved | 5/4/2020 | VARAND SARKISIAN |
| Issued | 6/22/2020 | APPLICANT |
| OK for CofC | 4/7/2021 | MARK FERRARI |
| CofC Issued | 4/13/2021 | ERNESTO CORRAL |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 5/19/2020 | MICHAEL SOTO |
Contact Information
| Contractor | American Retrofitters Corp; Lic. No.: 1020382-B | 15643 SHERMAN WAY STE 220 VAN NUYS, CA 91406 |
| Engineer | Mouser,, Louis Anthony; Lic. No.: C84994 | 616 MASSELIN AVE 225 LOS ANGELES, CA 90036 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 7/7/2020 | Approved | MARK FERRARI |
| Wood Frame | 7/7/2020 | Partial Approval | MARK FERRARI |
| Deputy Drilled-In Anchors | 7/10/2020 | Conditional Approval | FRED WOHLFARTH |
| Deputy Steel/Welding | 7/13/2020 | Conditional Approval | FRED WOHLFARTH |
| Deputy Drilled-In Anchors | 7/21/2020 | Conditional Approval | FRED WOHLFARTH |
| Footing/Foundation/Slab | 7/24/2020 | Approved | MARK FERRARI |
| Structural Steel Frame | 7/24/2020 | Approved | MARK FERRARI |
| Wood Frame | 7/24/2020 | Approved | MARK FERRARI |
| Deputy Reinf. Concrete | 7/28/2020 | Conditional Approval | MARK FERRARI |
| Interior/Exterior Lathing | 8/24/2020 | Not Ready for Inspection | MARK FERRARI |
| Interior/Exterior Lathing | 8/25/2020 | Approved | MARK FERRARI |
| Final | 3/18/2021 | Conditional Approval | JONATHAN QUACH |
| SGSOV-Seismic Gas S/O Valve | 3/18/2021 | SGSOV Approved | JONATHAN QUACH |
| Smoke Detectors | 3/18/2021 | Approved | JONATHAN QUACH |
| Final | 4/7/2021 | OK for CofC | MARK FERRARI |