1309 N DETROIT ST 90046

Certificate Information: 1309 N DETROIT ST 90046

Application / Permit
19016-10000-29292
Plan Check / Job No.
B19LA19526
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT PER LAMC Div. 93; INSTALL TWO STEEL CANTILEVER COLUMNS SYSTEM.
Permit Issued
Issued on 4/19/2021
Issuing Office
Current Status
CofC Issued on 12/11/2025

Permit Application Status History

Submitted 9/13/2019 APPLICANT
Assigned to Plan Check Engineer 10/23/2019 BIDYUT RATH
Corrections Issued 10/30/2019 BIDYUT RATH
Quality Review Completed 10/30/2019 SAI KHUM
Building Plans Picked Up 11/6/2019 APPLICANT
Plan Check Approved 5/6/2020 JESSE VIDUYA
Issued 4/19/2021 APPLICANT
OK for CofC 12/2/2022 VAHE KELEDJIAN
OK for CofC 12/2/2022 VAHE KELEDJIAN
CofC Issued 10/12/2023 WINSTON DUNNING
CofC Issued 12/11/2025 ERNESTO CORRAL

Permit Application Clearance Information

Housing rent stabilization Cleared 3/11/2021 MICHAEL SOTO

Contact Information

Contractor Alpha Structural Inc; Lic. No.: 663409-B 8334 FOOTHILL BLVD      SUNLAND, CA 91040
Engineer Farmand,, Anthony E; Lic. No.: C62595 2372 MORSE AVE STE 137      IRVINE, CA 92614

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 4/29/2021 Conditional Approval JONATHAN QUACH
Excavation/Setback/Form/Re-Bar 5/4/2021 Not Ready for Inspection JONATHAN QUACH
Pre-Inspection 5/4/2021 Corrections Issued JONATHAN QUACH
Wood Frame 5/4/2021 Not Ready for Inspection JONATHAN QUACH
Excavation/Setback/Form/Re-Bar 6/8/2021 Corrections Issued JONATHAN QUACH
Wood Frame 6/8/2021 Partial Approval JONATHAN QUACH
Excavation/Setback/Form/Re-Bar 6/10/2021 Approved BRUCE CAMPBELL
Floor/Roof Diaphrgm/Shear Wall 6/10/2021 Not Ready for Inspection BRUCE CAMPBELL
Floor/Roof Diaphrgm/Shear Wall 6/15/2021 Approved BRUCE CAMPBELL
Structural Steel Frame 6/15/2021 Approved BRUCE CAMPBELL
Final 4/5/2022 Not Ready for Inspection BRUCE CAMPBELL
SGSOV-Seismic Gas S/O Valve 4/5/2022 SGSOV Approved BRUCE CAMPBELL
Smoke Detectors 4/5/2022 Approved BRUCE CAMPBELL
Final 12/2/2022 OK for CofC VAHE KELEDJIAN