3611 S MENTONE AVE 90034

Certificate Information: 3611 S MENTONE AVE 90034

Application / Permit
19016-10000-26497
Plan Check / Job No.
B19LA17775
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Soft-Story seismic retrofit per LABC Chapter 93: INSTALL 5 NEW STEEL SPECIAL CANTILEVER COLUMN SYSTEMS AND NEW GRADE BEAMS.
Permit Issued
Issued on 1/18/2022
Issuing Office
Current Status
CofC Issued on 10/11/2022

Permit Application Status History

Submitted 8/23/2019 APPLICANT
Assigned to Plan Check Engineer 10/2/2019 DANIEL SANJUAN
Corrections Issued 10/11/2019 DANIEL SANJUAN
Quality Review Completed 10/17/2019 HANS SANTIAGO
Plan Check Approved 7/2/2021 DANIEL SANJUAN
Issued 1/18/2022 APPLICANT
OK for CofC 10/3/2022 GRANT WOODS
CofC Issued 10/11/2022 DAVID TSAU

Permit Application Clearance Information

Housing rent stabilization Cleared 8/19/2021 RICARDO BOHORQUEZ

Contact Information

Contractor Procon Builders Inc; Lic. No.: 977214-A 9526 TOPANGA CANYON BLVD      CHATSWORTH, CA 91311
Engineer Talebian,, Sasan; Lic. No.: C44216 12063A JEFFERSON BLVD      CULVER CITY, CA 90230

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 4/8/2022 Approved GRANT WOODS
Deputy Drilled-In Anchors 5/4/2022 Conditional Approval GRANT WOODS
Footing/Foundation/Slab 5/5/2022 Not Ready for Inspection PAUL DAVIDSON
Footing/Foundation/Slab 5/6/2022 Approved GRANT WOODS
Deputy Wood Construction 5/12/2022 Conditional Approval PAUL DAVIDSON
Floor/Roof Diaphrgm/Shear Wall 5/12/2022 Approved PAUL DAVIDSON
Interior/Exterior Lathing 5/27/2022 Approved GRANT WOODS
Final 10/3/2022 OK for CofC GRANT WOODS
SGSOV-Seismic Gas S/O Valve 10/3/2022 SGSOV Approved GRANT WOODS
Smoke Detectors 10/3/2022 Approved GRANT WOODS