11 E JIB ST 90292

Certificate Information: 11 E JIB ST 90292

Application / Permit
19016-10000-25801
Plan Check / Job No.
B19LA17325
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT-STORY SEISMIC RETROFIT PER LAMC DIVISION 93. INSTALLATION OF 3 SPECIAL CANTILEVERED COLUMN SYSTEM (SCCS) WITH CONCRETE GRADE BEAM. WORKS AT TUCK-UNDER PARKING AREAS, NOT ON TENANTS' UNITS.
Permit Issued
Issued on 8/19/2020
Issuing Office
Metro
Current Status
CofC Issued on 11/6/2020

Permit Application Status History

Submitted 8/16/2019 APPLICANT
Assigned to Plan Check Engineer 9/25/2019 ERWIN PASCUA
Corrections Issued 9/29/2019 ERWIN PASCUA
Quality Review Completed 10/3/2019 SAI KHUM
Building Plans Picked Up 1/10/2020 APPLICANT
Plan Check Approved 1/23/2020 ERWIN PASCUA
Issued 8/19/2020 APPLICANT
OK for CofC 11/5/2020 GRANT WOODS
CofC Issued 11/6/2020 TED RIES

Permit Application Clearance Information

Housing rent stabilization Cleared 7/21/2020 STEVEN HOFSTAD

Contact Information

Contractor Strong Ties Construction Inc; Lic. No.: 868377-B 767 N ALEXANDRIA AVENUE #3      LOS ANGELES, CA 90029
Engineer Mina,, Joseph Wadie; Lic. No.: C53465 7247 DARNOCH WY      WEST HILLS, CA 91307

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 9/2/2020 Approved GRANT WOODS
Footing/Foundation/Slab 9/17/2020 Partial Approval TIMOTHY BUXTON
Deputy Drilled-In Anchors 9/30/2020 Conditional Approval GRANT WOODS
Deputy Steel/Welding 9/30/2020 Conditional Approval GRANT WOODS
Footing/Foundation/Slab 9/30/2020 Partial Inspection GRANT WOODS
Footing/Foundation/Slab 10/1/2020 Approved GRANT WOODS
Deputy Reinf. Concrete 10/2/2020 Conditional Approval GRANT WOODS
Wood Frame 10/8/2020 Partial Approval GRANT WOODS
Floor/Roof Diaphrgm/Shear Wall 10/9/2020 Approved GRANT WOODS
Interior/Exterior Lathing 10/13/2020 Approved GRANT WOODS
Final 10/26/2020 Partial Inspection GRANT WOODS
METHANE-Final 10/26/2020 Approved GRANT WOODS
SGSOV-Seismic Gas S/O Valve 10/26/2020 SGSOV Approved GRANT WOODS
Smoke Detectors 10/26/2020 Not Ready for Inspection GRANT WOODS
Final 11/5/2020 OK for CofC GRANT WOODS
Smoke Detectors 11/5/2020 Approved GRANT WOODS