13055 W MOORPARK ST 91604

Certificate Information: 13055 W MOORPARK ST 91604

Application / Permit
19016-10000-24953
Plan Check / Job No.
B19LA16732
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT AS PER LABC CHAPTER 93 USING 1 SCC.
Permit Issued
Issued on 10/2/2020
Issuing Office
Current Status
CofC Issued on 4/21/2021

Permit Application Status History

Submitted 8/9/2019 APPLICANT
Assigned to Plan Check Engineer 9/18/2019 DANIEL SANJUAN
Corrections Issued 9/25/2019 DANIEL SANJUAN
Quality Review Completed 10/2/2019 SAI KHUM
Building Plans Picked Up 10/11/2019 APPLICANT
Plan Check Approved 10/23/2019 DANIEL SANJUAN
Issued 10/2/2020 APPLICANT
OK for CofC 3/22/2021 KENNETH ROBERTS
CofC Issued 4/21/2021 RICKEY JACKSON

Permit Application Clearance Information

Housing rent stabilization Cleared 10/1/2020 MICHAEL GREGERSON

Contact Information

Engineer Mirmohammadsadeghi,, Kamaleddin; Lic. No.: C53468 1377 S BEVERLY GLEN BLVD 308      LOS ANGELES, CA 90024

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 10/15/2020 Not Ready for Inspection JOE VELASQUEZ
Deputy Drilled-In Anchors 11/6/2020 No Access for Inspection JOE VELASQUEZ
Footing/Foundation/Slab 11/16/2020 Approved JOE VELASQUEZ
Wood Frame 11/19/2020 Not Ready for Inspection JOE VELASQUEZ
Insulation 11/23/2020 Approved JOE VELASQUEZ
Wood Frame 11/23/2020 Approved JOE VELASQUEZ
Drywall Nailing 11/30/2020 Approved ANDREW DORSO
Interior/Exterior Lathing 11/30/2020 Approved ANDREW DORSO
Final 12/7/2020 Corrections Issued DANIEL VARNUM
SGSOV-Seismic Gas S/O Valve 12/7/2020 SGSOV Not Ready DANIEL VARNUM
Smoke Detectors 12/7/2020 Not Ready for Inspection DANIEL VARNUM
Final 1/13/2021 Not Ready for Inspection JOE VELASQUEZ
SGSOV-Seismic Gas S/O Valve 1/13/2021 SGSOV Not Ready JOE VELASQUEZ
Smoke Detectors 1/13/2021 Not Ready for Inspection JOE VELASQUEZ
Final 2/25/2021 Not Ready for Inspection JOE VELASQUEZ
SGSOV-Seismic Gas S/O Valve 2/25/2021 SGSOV Not Ready JOE VELASQUEZ
Smoke Detectors 2/25/2021 Not Ready for Inspection JOE VELASQUEZ
Final 3/22/2021 OK for CofC KENNETH ROBERTS
SGSOV-Seismic Gas S/O Valve 3/22/2021 SGSOV Approved KENNETH ROBERTS
Smoke Detectors 3/22/2021 Approved KENNETH ROBERTS