4354 W OAKWOOD AVE 90004
Certificate Information: 4354 W OAKWOOD AVE 90004
- Application / Permit
- 19016-10000-24479
- Plan Check / Job No.
- B19LA16370
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH 93. INSTALL 2 NEW CANTILEVER COLUMNS AND NEW PLYWOOD SHEARWALL.
- Permit Issued
- Issued on 3/7/2022
- Issuing Office
- Current Status
- CofC Issued on 9/14/2022
Permit Application Status History
| Submitted | 8/7/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 9/11/2019 | DANIEL YIP |
| Corrections Issued | 9/17/2019 | DANIEL YIP |
| Quality Review Completed | 9/18/2019 | SAI KHUM |
| Building Plans Picked Up | 9/19/2019 | APPLICANT |
| Applicant returned to address corrections | 10/8/2019 | DANIEL YIP |
| Plan Check Approved | 10/9/2019 | DANIEL YIP |
| Issued | 3/7/2022 | APPLICANT |
| OK for CofC | 9/13/2022 | BRUCE CAMPBELL |
| CofC Issued | 9/14/2022 | WINSTON DUNNING |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 2/7/2022 | ISMAEL HERNANDEZ |
Contact Information
| Contractor | The Foundation Works; Lic. No.: 876769-B | 2411 WEST EMPIRE AVE BURBANK, CA 91505 |
| Engineer | Standley,, Craig Erick; Lic. No.: C87675 | 6631 MURIETTA AVE LOS ANGELES, CA 91405 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 4/11/2022 | Conditional Approval | DARRYL ARNOLD |
| Pre-Inspection | 4/14/2022 | Conditional Approval | BRUCE CAMPBELL |
| Footing/Foundation/Slab | 4/26/2022 | Approved | BRUCE CAMPBELL |
| Wood Frame | 4/26/2022 | Partial Approval | BRUCE CAMPBELL |
| Wood Frame | 5/18/2022 | Approved | BRUCE CAMPBELL |
| Interior/Exterior Lathing | 5/23/2022 | Corrections Issued | BRUCE CAMPBELL |
| Deputy Wood Construction | 8/4/2022 | Conditional Approval | BRUCE CAMPBELL |
| Final | 8/8/2022 | Not Ready for Inspection | BRUCE CAMPBELL |
| SGSOV-Seismic Gas S/O Valve | 8/8/2022 | SGSOV Approved | BRUCE CAMPBELL |
| Smoke Detectors | 8/8/2022 | Not Ready for Inspection | BRUCE CAMPBELL |
| Final | 9/13/2022 | OK for CofC | BRUCE CAMPBELL |
| Smoke Detectors | 9/13/2022 | Approved | BRUCE CAMPBELL |