4354 W OAKWOOD AVE 90004

Certificate Information: 4354 W OAKWOOD AVE 90004

Application / Permit
19016-10000-24479
Plan Check / Job No.
B19LA16370
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT AS PER LABC CH 93. INSTALL 2 NEW CANTILEVER COLUMNS AND NEW PLYWOOD SHEARWALL.
Permit Issued
Issued on 3/7/2022
Issuing Office
Current Status
CofC Issued on 9/14/2022

Permit Application Status History

Submitted 8/7/2019 APPLICANT
Assigned to Plan Check Engineer 9/11/2019 DANIEL YIP
Corrections Issued 9/17/2019 DANIEL YIP
Quality Review Completed 9/18/2019 SAI KHUM
Building Plans Picked Up 9/19/2019 APPLICANT
Applicant returned to address corrections 10/8/2019 DANIEL YIP
Plan Check Approved 10/9/2019 DANIEL YIP
Issued 3/7/2022 APPLICANT
OK for CofC 9/13/2022 BRUCE CAMPBELL
CofC Issued 9/14/2022 WINSTON DUNNING

Permit Application Clearance Information

Housing rent stabilization Cleared 2/7/2022 ISMAEL HERNANDEZ

Contact Information

Contractor The Foundation Works; Lic. No.: 876769-B 2411 WEST EMPIRE AVE      BURBANK, CA 91505
Engineer Standley,, Craig Erick; Lic. No.: C87675 6631 MURIETTA AVE      LOS ANGELES, CA 91405

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 4/11/2022 Conditional Approval DARRYL ARNOLD
Pre-Inspection 4/14/2022 Conditional Approval BRUCE CAMPBELL
Footing/Foundation/Slab 4/26/2022 Approved BRUCE CAMPBELL
Wood Frame 4/26/2022 Partial Approval BRUCE CAMPBELL
Wood Frame 5/18/2022 Approved BRUCE CAMPBELL
Interior/Exterior Lathing 5/23/2022 Corrections Issued BRUCE CAMPBELL
Deputy Wood Construction 8/4/2022 Conditional Approval BRUCE CAMPBELL
Final 8/8/2022 Not Ready for Inspection BRUCE CAMPBELL
SGSOV-Seismic Gas S/O Valve 8/8/2022 SGSOV Approved BRUCE CAMPBELL
Smoke Detectors 8/8/2022 Not Ready for Inspection BRUCE CAMPBELL
Final 9/13/2022 OK for CofC BRUCE CAMPBELL
Smoke Detectors 9/13/2022 Approved BRUCE CAMPBELL