12750 W MATTESON AVE 90066

Certificate Information: 12750 W MATTESON AVE 90066

Application / Permit
19016-10000-22058
Plan Check / Job No.
B19LA14826
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT PER LABC CH 93. 2 NEW STEEL SPECIAL CANTILEVER COLUMN AND (1) SHEAR WALL.
Permit Issued
Issued on 9/17/2021
Issuing Office
Current Status
CofC Issued on 2/17/2022

Permit Application Status History

Submitted 7/18/2019 APPLICANT
Assigned to Plan Check Engineer 8/21/2019 DANIEL SANJUAN
Corrections Issued 8/27/2019 DANIEL SANJUAN
Quality Review Completed 8/29/2019 SAI KHUM
Building Plans Picked Up 11/12/2019 APPLICANT
Plan Check Approved 8/19/2020 DANIEL SANJUAN
Issued 9/17/2021 APPLICANT
OK for CofC 2/11/2022 JOHN DODGE
CofC Issued 2/17/2022 HENRY BAGHDASSARIAN

Permit Application Clearance Information

Housing rent stabilization Cleared 8/20/2021 PHILLIP MUNGUIA

Contact Information

Contractor Procon Builders Inc; Lic. No.: 977214-A 9526 TOPANGA CANYON BLVD      CHATSWORTH, CA 91311
Engineer Talebian,, Sasan; Lic. No.: C44216 12063A JEFFERSON BLVD      CULVER CITY, CA 90230

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 10/13/2021 Approved GRANT WOODS
Wall Anchors 10/13/2021 Partial Inspection GRANT WOODS
Wood Frame 10/13/2021 Not Ready for Inspection GRANT WOODS
Wall Anchors 10/14/2021 Approved GRANT WOODS
Wood Frame 10/14/2021 Partial Approval GRANT WOODS
Deputy Drilled-In Anchors 10/20/2021 Conditional Approval ALAN NOVAK
Deputy Steel/Welding 10/20/2021 Conditional Approval ALAN NOVAK
Excavation/Setback/Form/Re-Bar 10/20/2021 Not Ready for Inspection ALAN NOVAK
Footing/Foundation/Slab 10/20/2021 Not Ready for Inspection ALAN NOVAK
Deputy Wood Construction 10/28/2021 Conditional Approval JOHN DODGE
Footing/Foundation/Slab 10/28/2021 Approved JOHN DODGE
Wood Frame 10/28/2021 Approved JOHN DODGE
Deputy Reinf. Concrete 11/1/2021 Conditional Approval JOHN DODGE
Interior/Exterior Lathing 11/9/2021 Approved GRANT WOODS
Final 2/9/2022 Not Ready for Inspection GRANT WOODS
SGSOV-Seismic Gas S/O Valve 2/9/2022 SGSOV Approved GRANT WOODS
Smoke Detectors 2/9/2022 Not Ready for Inspection GRANT WOODS
Final 2/11/2022 OK for CofC JOHN DODGE
SGSOV-Seismic Gas S/O Valve 2/11/2022 SGSOV Approved JOHN DODGE
Smoke Detectors 2/11/2022 Approved JOHN DODGE