654 N COMMONWEALTH AVE 90029

Certificate Information: 654 N COMMONWEALTH AVE 90029

Application / Permit
19016-10000-14585
Plan Check / Job No.
B19LA10134
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT PER LABC CHAPTER 93. INSTALL (1) OMF AND (2) SCCS.
Permit Issued
Issued on 3/24/2021
Issuing Office
Current Status
CofC Issued on 7/19/2021

Permit Application Status History

Submitted 5/16/2019 APPLICANT
Assigned to Plan Check Engineer 6/12/2019 EVERARDO SANTOS
Corrections Issued 6/18/2019 EVERARDO SANTOS
Quality Review Completed 6/18/2019 SAI KHUM
Building Plans Picked Up 6/26/2019 APPLICANT
Plan Check Approved 8/19/2019 EVERARDO SANTOS
Issued 3/24/2021 APPLICANT
OK for CofC 7/16/2021 BRUCE CAMPBELL
CofC Issued 7/19/2021 WINSTON DUNNING

Permit Application Clearance Information

Address approval Cleared 7/30/2019 ELAINE LEI
Eng Process Fee Ord 176,300 Cleared 7/30/2019 ELAINE LEI
Housing rent stabilization Cleared 3/23/2021 PHILLIP MUNGUIA

Contact Information

Contractor Optimum Seismic Inc; Lic. No.: 1012702-B 5508 S SANTA FE AVENUE      VERNON, CA 90058
Engineer Mirmohammadsadeghi,, Kamaleddin; Lic. No.: C53468 1377 S BEVERLY GLEN BLVD 308      LOS ANGELES, CA 90024

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 3/31/2021 Approved MARK FERRARI
Deputy Steel/Welding 4/1/2021 Conditional Approval FRED WOHLFARTH
Deputy Drilled-In Anchors 4/7/2021 Conditional Approval JONATHAN QUACH
Deputy Steel/Welding 4/8/2021 Conditional Approval FRED WOHLFARTH
Footing/Foundation/Slab 4/8/2021 Approved MARK FERRARI
Structural Steel Frame 4/8/2021 Corrections Issued MARK FERRARI
Wood Frame 4/8/2021 Approved MARK FERRARI
Deputy Reinf. Concrete 4/9/2021 Conditional Approval JONATHAN QUACH
Structural Steel Frame 4/12/2021 Approved MARK FERRARI
Interior/Exterior Lathing 4/15/2021 Corrections Issued MARK FERRARI
Final 6/9/2021 Conditional Approval BRUCE CAMPBELL
SGSOV-Seismic Gas S/O Valve 6/9/2021 SGSOV Approved BRUCE CAMPBELL
Smoke Detectors 6/9/2021 Approved BRUCE CAMPBELL
Final 7/16/2021 OK for CofC BRUCE CAMPBELL