4423 W AMBROSE AVE 90027

Certificate Information: 4423 W AMBROSE AVE 90027

Application / Permit
19016-10000-08489
Plan Check / Job No.
B19LA06041
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT AS PER LABC CH. 93 USING 3 SCCS AND 1 SHEARWALL.
Permit Issued
Issued on 5/12/2021
Issuing Office
Current Status
CofC Issued on 11/1/2021

Permit Application Status History

Submitted 3/26/2019 APPLICANT
Assigned to Plan Check Engineer 4/17/2019 EVERARDO SANTOS
Corrections Issued 4/24/2019 EVERARDO SANTOS
Quality Review Completed 4/25/2019 SAI KHUM
Building Plans Picked Up 5/7/2019 APPLICANT
Plan Check Approved 6/26/2019 EVERARDO SANTOS
Issued 5/12/2021 APPLICANT
OK for CofC 10/27/2021 BRUCE CAMPBELL
CofC Issued 11/1/2021 WINSTON DUNNING

Permit Application Clearance Information

Housing rent stabilization Cleared 5/5/2021 MICHAEL SOTO

Contact Information

Contractor Parthenon Structures Inc; Lic. No.: 1056070-B 3300 FOOTHILL BLVD #8601      LA CRESCENTA, CA 91214
Engineer Hagopyan,, Edmond; Lic. No.: C80143 7939 WENTWORTH STREET      SUNLAND, CA 91040

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 8/18/2021 Corrections Issued BRUCE CAMPBELL
Deputy Drilled-In Anchors 8/26/2021 Conditional Approval BRUCE CAMPBELL
Wood Frame 9/9/2021 Partial Approval BRUCE CAMPBELL
Floor/Roof Diaphrgm/Shear Wall 9/23/2021 Approved BRUCE CAMPBELL
Footing/Foundation/Slab 9/23/2021 Approved BRUCE CAMPBELL
Structural Steel Frame 9/23/2021 Approved BRUCE CAMPBELL
Wood Frame 9/23/2021 Approved BRUCE CAMPBELL
Deputy Drilled-In Anchors 9/24/2021 Conditional Approval BRUCE CAMPBELL
Deputy Wood Construction 9/24/2021 Conditional Approval BRUCE CAMPBELL
Deputy Reinf. Concrete 9/28/2021 Conditional Approval BRUCE CAMPBELL
Drywall Nailing 10/7/2021 Approved BRUCE CAMPBELL
Interior/Exterior Lathing 10/7/2021 Corrections Issued BRUCE CAMPBELL
Interior/Exterior Lathing 10/13/2021 Corrections Issued BRUCE CAMPBELL
SGSOV-Seismic Gas S/O Valve 10/13/2021 SGSOV Not Ready BRUCE CAMPBELL
Final 10/27/2021 OK for CofC BRUCE CAMPBELL
SGSOV-Seismic Gas S/O Valve 10/27/2021 SGSOV Approved BRUCE CAMPBELL
Smoke Detectors 10/27/2021 Approved BRUCE CAMPBELL