519 N ARDMORE AVE 90004

Certificate Information: 519 N ARDMORE AVE 90004

Application / Permit
19016-10000-05748
Plan Check / Job No.
B19LA04064
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Soft-Story seismic retrofit per LABC Chapter 93: Install new STEEL SPECIAL CANTILEVERED COLUMN .
Permit Issued
Issued on 11/24/2020
Issuing Office
Current Status
CofC Issued on 11/23/2021

Permit Application Status History

Submitted 3/5/2019 APPLICANT
Assigned to Plan Check Engineer 3/20/2019 DANIEL SANJUAN
Corrections Issued 3/29/2019 DANIEL SANJUAN
Quality Review Completed 4/1/2019 HANS SANTIAGO
Plan Check Approved 2/11/2020 DANIEL SANJUAN
Issued 11/24/2020 APPLICANT
OK for CofC 11/16/2021 BRUCE CAMPBELL
CofC Issued 11/23/2021 WINSTON DUNNING

Permit Application Clearance Information

Housing rent stabilization Cleared 8/4/2020 PHILLIP MUNGUIA

Contact Information

Contractor National Retrofit Service Inc; Lic. No.: 1062123-B 4456 ALTA CANYADA RD      LA CANADA FLINTRIDGE, CA 91011
Engineer Puliyadi,, Senthilnath Surendran; Lic. No.: NA71630       ,

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 10/15/2021 Partial Approval BRUCE CAMPBELL
Deputy Reinf. Concrete 10/22/2021 Conditional Approval BRUCE CAMPBELL
Reinforced Concrete Frame 10/25/2021 Not Ready for Inspection BRUCE CAMPBELL
Structural Steel Frame 10/25/2021 Approved BRUCE CAMPBELL
Structural Steel Frame 10/29/2021 Conditional Approval BRUCE CAMPBELL
Wood Frame 10/29/2021 Approved BRUCE CAMPBELL
Interior/Exterior Lathing 11/4/2021 Approved BRUCE CAMPBELL
Final 11/16/2021 OK for CofC BRUCE CAMPBELL
SGSOV-Seismic Gas S/O Valve 11/16/2021 SGSOV Approved BRUCE CAMPBELL
Smoke Detectors 11/16/2021 Approved BRUCE CAMPBELL