927 W 9TH ST 90731
Certificate Information: 927 W 9TH ST 90731
- Application / Permit
- 19016-10000-00981
- Plan Check / Job No.
- B19LA00693
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH. 93 USING NEW ORDINERY MOMENT FRAME .
- Permit Issued
- Issued on 8/17/2020
- Issuing Office
- Current Status
- OK for CofC on 1/6/2021
Permit Application Status History
| Submitted | 1/11/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 2/13/2019 | VARAND SARKISIAN |
| Corrections Issued | 2/19/2019 | VARAND SARKISIAN |
| Quality Review Completed | 2/22/2019 | HANS SANTIAGO |
| Building Plans Picked Up | 6/20/2019 | APPLICANT |
| Plan Check Approved | 7/18/2019 | VARAND SARKISIAN |
| Issued | 8/17/2020 | APPLICANT |
| OK for CofC | 1/6/2021 | JOEY BUCHANAN |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 8/3/2020 | ISMAEL HERNANDEZ |
Contact Information
| Contractor | Julian Construction Inc; Lic. No.: 788526-B | 2900 W JEFFERSON BLVD LOS ANGELES, CA 90018 |
| Engineer | Downey,, Henry Ross; Lic. No.: S2628 | 7463 VARNA AVE NORTH HOLLYWOOD, CA 916054011 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 8/26/2020 | Corrections Issued | JOEY BUCHANAN |
| Excavation/Setback/Form/Re-Bar | 11/18/2020 | Approved | JOEY BUCHANAN |
| Wood Frame | 11/18/2020 | Approved | JOEY BUCHANAN |
| Deputy Reinf. Concrete | 11/19/2020 | Approved | JOEY BUCHANAN |
| Interior/Exterior Lathing | 12/2/2020 | Approved | JOEY BUCHANAN |
| Final | 1/6/2021 | OK for CofC | JOEY BUCHANAN |
| SGSOV-Seismic Gas S/O Valve | 1/6/2021 | SGSOV Approved | JOEY BUCHANAN |
| Smoke Detectors | 1/6/2021 | Approved | JOEY BUCHANAN |