Application / Permit
19014-40000-05452
Plan Check / Job No.
B19SP01554
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
One-story ground floor addition (1,198 SF) to (E) one-story detached garage to create Accessory Dwelling Unit per SB229 and AB494 with two-car garage. All work per WFPP.
Permit Issued
Issued on 7/1/2020
Issuing Office
Current Status
CofO Issued on 1/15/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 10/4/2019 APPLICANT
Assigned to Plan Check Engineer 10/31/2019 KAMRAN GHOTBI RAVANDI
Corrections Issued 11/5/2019 KAMRAN GHOTBI RAVANDI
Quality Review Completed 11/14/2019 FELIX FIGUEROA
Green Plans Picked Up 5/5/2020 APPLICANT
Applicant returned to address corrections 5/15/2020 KAMRAN GHOTBI RAVANDI
Plan Check Approved 6/24/2020 KAMRAN GHOTBI RAVANDI
Issued 7/1/2020 APPLICANT
Building Plans Picked Up 7/1/2020 APPLICANT
CofO in Progress 1/14/2021 ANSON MAGLASANG
Permit Finaled 1/15/2021 DEROLD HAUFF
CofO Issued 1/15/2021 DEROLD HAUFF
Permit Finaled 1/15/2021 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 1/8/2020 EMIL KYUPELYAN
Eng Process Fee Ord 176,300 Cleared 1/8/2020 EMIL KYUPELYAN
Sewer availability Cleared 1/8/2020 EMIL KYUPELYAN
Low Impact Development Cleared 4/14/2020 MARTIN FRAGOSO
Roof/Waste drainage to street Cleared 4/16/2020 EMIL KYUPELYAN
Green Code Cleared 5/1/2020 RICHARD GARCIA

Contact Information

Contractor Frisco Investment Group Inc; Lic. No.: 1038932-B 2851 W 120TH ST STE #E112      HAWTHORNE, CA 90250

Inspector Information

BEN MOLSTAD, (310) 732-4557 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 7/14/2020 Partial Approval EUGENE CASSIDY
Pre-Inspection 7/14/2020 Partial Approval EUGENE CASSIDY
Footing/Foundation/Slab 7/20/2020 Approved EUGENE CASSIDY
METHANE-Barrier 7/20/2020 Approved EUGENE CASSIDY
METHANE-Subgrade 7/20/2020 Approved EUGENE CASSIDY
PLUMBING-Rough 7/27/2020 Corrections Issued JOHN KLARIN
Insulation 7/29/2020 Corrections Issued EUGENE CASSIDY
PLUMBING-Rough 7/29/2020 Approved EUGENE CASSIDY
Floor/Roof Diaphrgm/Shear Wall 7/31/2020 Partial Approval EUGENE CASSIDY
Insulation 7/31/2020 Partial Approval EUGENE CASSIDY
Floor/Roof Diaphrgm/Shear Wall 8/3/2020 Approved EUGENE CASSIDY
BUILDING-Rough-Frame 9/2/2020 Corrections Issued EUGENE CASSIDY
ELECTRICAL-Rough 9/2/2020 Approved EUGENE CASSIDY
Green Building Rough 9/2/2020 Corrections Issued EUGENE CASSIDY
HVAC-Rough 9/2/2020 Approved EUGENE CASSIDY
MERV13>=Rough 9/2/2020 Approved EUGENE CASSIDY
METHANE-Rough 9/2/2020 Approved EUGENE CASSIDY
PLUMBING-Rough 9/2/2020 Approved EUGENE CASSIDY
Rough-Elec/Plmb/HVAC 9/3/2020 Approved EUGENE CASSIDY
Wood Frame 9/3/2020 Approved EUGENE CASSIDY
BUILDING-Rough-Frame 9/11/2020 Approved EUGENE CASSIDY
Green Building Rough 9/11/2020 Approved EUGENE CASSIDY
Insulation 9/11/2020 Approved EUGENE CASSIDY
Interior/Exterior Lathing 9/11/2020 Approved EUGENE CASSIDY
Drywall Nailing 9/17/2020 Approved EUGENE CASSIDY
Sewer 10/26/2020 Approved EUGENE CASSIDY
ELECTRICAL-Final 12/17/2020 Not Ready for Inspection EUGENE CASSIDY
Final 12/17/2020 Corrections Issued EUGENE CASSIDY
Gas Test 12/17/2020 Approved EUGENE CASSIDY
Green Building Final 12/17/2020 Corrections Issued EUGENE CASSIDY
HVAC-Final 12/17/2020 Not Ready for Inspection EUGENE CASSIDY
MERV13>=Final 12/17/2020 Not Ready for Inspection EUGENE CASSIDY
PLUMBING-Final 12/17/2020 Not Ready for Inspection EUGENE CASSIDY
SGSOV-Seismic Gas S/O Valve 12/17/2020 SGSOV Approved EUGENE CASSIDY
Smoke Detectors 12/17/2020 Approved EUGENE CASSIDY
ELECTRICAL-Final 1/7/2021 Approved EUGENE CASSIDY
Final 1/7/2021 Corrections Issued EUGENE CASSIDY
Gas Test 1/7/2021 Approved EUGENE CASSIDY
Green Building Final 1/7/2021 Approved EUGENE CASSIDY
HVAC-Final 1/7/2021 Approved EUGENE CASSIDY
MERV13>=Final 1/7/2021 Approved EUGENE CASSIDY
PLUMBING-Final 1/7/2021 Approved EUGENE CASSIDY
Service/Power Release 1/7/2021 Not Ready for Inspection EUGENE CASSIDY
ELECTRICAL-Final 1/12/2021 Approved EUGENE CASSIDY
Final 1/12/2021 OK to Issue CofO EUGENE CASSIDY
Service/Power Release 1/12/2021 Approved EUGENE CASSIDY