6426 W 85TH PL 90045
Certificate Information: 6426 W 85TH PL 90045
- Application / Permit
- 19014-30000-04506
- Plan Check / Job No.
- B19WL04682
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 1 story addition to (E) 1 story SFD.
- Permit Issued
- Issued on 3/16/2020
- Issuing Office
- Metro
- Current Status
- CofO Issued on 4/26/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/20/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 8/21/2019 | VLADIMIR ARUTYUNYAN |
| Corrections Issued | 8/21/2019 | VLADIMIR ARUTYUNYAN |
| Building Plans Picked Up | 8/28/2019 | APPLICANT |
| Plan Check Approved | 10/11/2019 | REZA HAGHIGHAT |
| Issued | 3/16/2020 | LADBS |
| CofO in Progress | 4/26/2025 | DAVID FEILER |
| Permit Finaled | 4/26/2025 | RICHARD STEINBACH |
| CofO Issued | 4/26/2025 | RICHARD STEINBACH |
| Permit Finaled | 4/26/2025 | RICHARD STEINBACH |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 10/10/2019 | THOMAS LANG |
| Sewer availability | Cleared | 10/10/2019 | THOMAS LANG |
| Low Impact Development | Cleared | 10/11/2019 | ANDRES COVARRUBIAS |
| Roof/Waste drainage to street | Cleared | 10/11/2019 | JEANETTE VONG |
Contact Information
| Architect | Chun,, Youngmin; Lic. No.: C32890 | 1828 LINCOLN BLVD #B SANTA MONICA, CA 90404 |
| Contractor | Lazobuild Inc; Lic. No.: 1001909-B | 3592 ROSEMEAD BLVD #219 ROSEMEAD, CA 91770 |
| Engineer | Lee,, Sang Youck; Lic. No.: S3821 | 3531 BROOKHILL ST GLENDALE, CA 91214 |
Inspector Information
| MORRIS JACKSON, (310) 914-3885 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 5/15/2020 | Conditional Approval | JOHNNY MIRANDA |
| Excavation/Setback/Form/Re-Bar | 6/2/2020 | Partial Approval | JOHNNY MIRANDA |
| PLUMBING-Rough | 6/2/2020 | Corrections Issued | JOHNNY MIRANDA |
| Footing/Foundation/Slab | 6/5/2020 | Approved | JOHNNY MIRANDA |
| Underground Mechanical | 6/5/2020 | Approved | JOHNNY MIRANDA |
| ELECTRICAL-Rough | 9/22/2020 | Approved | JOHNNY MIRANDA |
| Deputy Drilled-In Anchors | 9/25/2020 | Conditional Approval | JOHNNY MIRANDA |
| BUILDING-Rough-Frame | 10/2/2020 | Corrections Issued | JOHNNY MIRANDA |
| Green Building Rough | 10/2/2020 | Not Ready for Inspection | JOHNNY MIRANDA |
| PLUMBING-Rough | 10/2/2020 | Corrections Issued | JOHNNY MIRANDA |
| Floor/Roof Diaphrgm/Shear Wall | 10/9/2020 | Approved | JUAN VALENZUELA |
| Green Building Rough | 10/9/2020 | Not Ready for Inspection | JUAN VALENZUELA |
| BUILDING-Rough-Frame | 10/19/2020 | Approved | JOHNNY MIRANDA |
| Green Building Rough | 10/19/2020 | Approved | JOHNNY MIRANDA |
| Interior/Exterior Lathing | 10/19/2020 | Partial Approval | JOHNNY MIRANDA |
| Insulation | 10/23/2020 | Corrections Issued | PIERRE VEGA |
| Insulation | 11/2/2020 | Approved | JOHNNY MIRANDA |
| Drywall Nailing | 11/6/2020 | Approved | JOHNNY MIRANDA |
| Shower Pan | 1/6/2021 | Corrections Issued | JOHNNY MIRANDA |
| Shower Pan | 1/7/2021 | Corrections Issued | JOHNNY MIRANDA |
| Shower Pan | 1/11/2021 | Approved | DAVID HEINE |
| Final | 2/12/2021 | Corrections Issued | DAVID HEINE |
| Green Building Final | 2/12/2021 | Approved | DAVID HEINE |
| SGSOV-Seismic Gas S/O Valve | 2/12/2021 | SGSOV Approved | DAVID HEINE |
| Smoke Detectors | 2/12/2021 | Approved | DAVID HEINE |
| Final | 4/26/2025 | OK to Issue CofO | DAVID FEILER |