3235 N CRAIG DR 90068

Certificate Information: 3235 N CRAIG DR 90068

Application / Permit
19014-20000-07152
Plan Check / Job No.
B19VN22617
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ADD (19'-11"x 25'-8") IRR SHAPE KITCHEN WITH STORAGE BASEMENT TO (E) SINGLE FAMILY DWELLING. WORK PER ENGINEER.
Permit Issued
Issued on 8/4/2020
Issuing Office
Current Status
CofO Issued on 4/18/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 12/30/2019 APPLICANT
Assigned to Plan Check Engineer 2/6/2020 TROY DEGUZMAN
Green Plans Picked Up 2/6/2020 APPLICANT
Corrections Issued 2/12/2020 TROY DEGUZMAN
Quality Review Completed 2/12/2020 CHON CHIO KUO
Building Plans Picked Up 2/14/2020 APPLICANT
Applicant returned to address corrections 7/16/2020 TROY DEGUZMAN
Applicant returned to address corrections 7/30/2020 TROY DEGUZMAN
Plan Check Approved 8/4/2020 TROY DEGUZMAN
Issued 8/4/2020 APPLICANT
CofO in Progress 4/17/2024 BRIAN SULLIVAN
Permit Finaled 4/18/2024 RONALD MYRICK
CofO Issued 4/18/2024 RONALD MYRICK
Permit Finaled 4/18/2024 RONALD MYRICK

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 2/25/2020 JOHN TRIANTAFYLLOS
Roof/Waste drainage to street Cleared 2/25/2020 JOHN TRIANTAFYLLOS
Sewer availability Cleared 2/25/2020 JOHN TRIANTAFYLLOS
Green Code Cleared 5/18/2020 DAVID MATSON
Hydrant and Access approval Cleared 6/26/2020 MATTHEW CRAIG
GPI Written Notices Cleared 7/15/2020 TROY DEGUZMAN
Grading Pre-Inspection Cleared 7/15/2020 TROY DEGUZMAN

Contact Information

Contractor Owner-Builder       ,
Engineer Ostowari,, Sohrab; Lic. No.: C41014 7012 HELMSDALE RD      WEST HILLS, CA 91307

Inspector Information

ROY SPAULDING, (213) 202-3461 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 10/19/2020 Partial Approval BRIAN SULLIVAN
Reinforced Concrete Frame 10/28/2020 Corrections Issued BRIAN SULLIVAN
Reinforced Concrete Frame 10/30/2020 Partial Approval BRIAN SULLIVAN
Deputy Reinf. Concrete 11/4/2020 Conditional Approval BRIAN SULLIVAN
Excavation/Setback/Form/Re-Bar 11/4/2020 Not Ready for Inspection BRIAN SULLIVAN
Excavation/Setback/Form/Re-Bar 11/25/2020 Partial Approval BRIAN SULLIVAN
Excavation/Setback/Form/Re-Bar 12/7/2020 Partial Approval BRIAN SULLIVAN
Deputy Reinf. Concrete 12/9/2020 Conditional Approval BRIAN SULLIVAN
Footing/Foundation/Slab 1/15/2021 Partial Approval BRIAN SULLIVAN
Excavation/Setback/Form/Re-Bar 1/21/2021 Approved BRIAN SULLIVAN
Floor/Roof Diaphrgm/Shear Wall 2/26/2021 Partial Approval BRIAN SULLIVAN
BUILDING-Rough-Frame 4/20/2021 Conditional Approval BRIAN SULLIVAN
ELECTRICAL-Rough 4/20/2021 Approved BRIAN SULLIVAN
Gas Test 4/20/2021 Partial Approval BRIAN SULLIVAN
HVAC-Rough 4/20/2021 Approved BRIAN SULLIVAN
Interior/Exterior Lathing 4/20/2021 Approved BRIAN SULLIVAN
PLUMBING-Rough 4/20/2021 Approved BRIAN SULLIVAN
Insulation 4/29/2021 Approved BRIAN SULLIVAN
Drywall Nailing 5/4/2021 Approved BRIAN SULLIVAN
Green Building Rough 5/4/2021 Approved BRIAN SULLIVAN
BUILDING-Rough-Frame 11/19/2021 Approved BRIAN SULLIVAN
Final 11/19/2021 Corrections Issued BRIAN SULLIVAN
Footing/Foundation/Slab 11/19/2021 Approved BRIAN SULLIVAN
Green Building Final 11/19/2021 Approved BRIAN SULLIVAN
SGSOV-Seismic Gas S/O Valve 11/19/2021 SGSOV Not Ready BRIAN SULLIVAN
Smoke Detectors 11/19/2021 Approved BRIAN SULLIVAN
Final 12/27/2021 Conditional Approval RAUL BARAJAS
SGSOV-Seismic Gas S/O Valve 12/27/2021 SGSOV Approved RAUL BARAJAS
Final 4/17/2024 OK to Issue CofO BRIAN SULLIVAN