5725 N CORTEEN PL 91607

Certificate Information: 5725 N CORTEEN PL 91607

Application / Permit
19014-20000-06490
Plan Check / Job No.
B19VN20789
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ADDITION of 9'x11'9" and irregular 8'x9'2" square-feet and a 6.5'x8' Entry Porch and a 12'x29.5' patio cover. Alteration that results in four bedrooms, 3-1/2 bathrooms, utility room, and kitchen/dining room/living room.
Permit Issued
Issued on 1/13/2020
Issuing Office
Valley
Current Status
CofO Issued on 3/14/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 11/27/2019 APPLICANT
Green Plans Picked Up 12/10/2019 APPLICANT
Assigned to Plan Check Engineer 12/12/2019 LUIS RINCON
Corrections Issued 12/30/2019 LUIS RINCON
Quality Review Completed 12/30/2019 CHON CHIO KUO
Building Plans Picked Up 12/30/2019 APPLICANT
Plan Check Approved 1/13/2020 LUIS RINCON
Issued 1/13/2020 LADBS
CofO in Progress 10/27/2020 BRENDAN LOONEY
CofO Issued 3/14/2022 MICHAEL SMITH
Permit Finaled 3/14/2022 MICHAEL SMITH

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 1/3/2020 GUILLERMO PETRA
Green Code Cleared 1/3/2020 AARON COSTA
Sewer availability Cleared 1/3/2020 GUILLERMO PETRA
Low Impact Development Cleared 1/7/2020 SARAH YOUSSEF
Roof/Waste drainage to street Cleared 1/7/2020 LEE GUILBEAUX
Public Works-Highway Ded. Cleared 1/7/2020 LEE GUILBEAUX

Contact Information

Architect Dembsky,, Amit; Lic. No.: C30383 5739 KANAN ROAD # 133      AGOURA HILLS, CA 91301
Contractor Owner-Builder       ,
Engineer Soni,, Mehul H; Lic. No.: C85355 5213 RETREAT CIR      LONGMONT, CO 80503

Inspector Information

WAYNE REGESTER, (818) 374-1164 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 1/17/2020 Approved GREG ALLTON
Floor/Roof Diaphrgm/Shear Wall 2/10/2020 Partial Approval GREG ALLTON
PLUMBING-Rough 2/10/2020 Not Ready for Inspection GREG ALLTON
Sewer 2/10/2020 Partial Approval GREG ALLTON
PLUMBING-Rough 2/13/2020 Partial Approval GREG ALLTON
ELECTRICAL-Rough 3/2/2020 Partial Approval GREG ALLTON
PLUMBING-Rough 3/2/2020 Approved GREG ALLTON
Wood Frame 3/2/2020 Partial Approval GREG ALLTON
Interior/Exterior Lathing 3/9/2020 Partial Approval GREG ALLTON
Shower Pan 3/9/2020 Approved GREG ALLTON
ELECTRICAL-Rough 3/12/2020 Not Ready for Inspection GREG ALLTON
Sewer 3/12/2020 Not Ready for Inspection GREG ALLTON
ELECTRICAL-Rough 3/16/2020 Partial Approval GREG ALLTON
Insulation 3/26/2020 Approved JEFFREY PARD
Drywall Nailing 3/31/2020 Approved TROY SANDERS
Green Building Rough 3/31/2020 Approved TROY SANDERS
BUILDING-Rough-Frame 6/19/2020 Approved BRENDAN LOONEY
Final 6/19/2020 Not Ready for Inspection BRENDAN LOONEY
Green Building Final 6/19/2020 Not Ready for Inspection BRENDAN LOONEY
SGSOV-Seismic Gas S/O Valve 6/19/2020 SGSOV Approved BRENDAN LOONEY
Smoke Detectors 6/19/2020 Approved BRENDAN LOONEY
Final 6/25/2020 Not Ready for Inspection BRENDAN LOONEY
Green Building Final 6/25/2020 Approved BRENDAN LOONEY
Final 8/24/2020 Partial Approval MATTHEW NELSON
Final 10/26/2020 OK to Issue CofO BRENDAN LOONEY