5724 N MANTON AVE 91367
Certificate Information: 5724 N MANTON AVE 91367
- Application / Permit
- 19014-20000-06201
- Plan Check / Job No.
- B19VN19832
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- REMOVE ALL EXTERIOR AND INTERIOR WALLS OF AN EXISTING ONE STORY DWELLING EXCEPT FOR 19'1" LF AT NORTH SIDE AND 10'6" LF AT SOUTH SIDE AND BUILD AN IRREGULAR 87' X 79'6" ONE STORY SINGLE FAMILY DWELLING WITH ATTACHED THREE CAR GARAGE, NFPA-13D FIRE SPRINKLERS THROUGHOUT REQUIRED , ALL WORK PER ENGINEERING
- Permit Issued
- Issued on 1/6/2020
- Issuing Office
- Valley
- Current Status
- CofO Issued on 11/24/2020
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/14/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 11/21/2019 | RARES BODEA |
| Corrections Issued | 11/24/2019 | RARES BODEA |
| Quality Review Completed | 11/26/2019 | GUANG MIN TUNG |
| Building Plans Picked Up | 11/26/2019 | APPLICANT |
| Green Plans Picked Up | 11/26/2019 | APPLICANT |
| Applicant returned to address corrections | 1/2/2020 | RARES BODEA |
| Plan Check Approved | 1/2/2020 | RARES BODEA |
| Issued | 1/6/2020 | LADBS |
| CofO in Progress | 11/23/2020 | TROY SANDERS |
| Permit Finaled | 11/24/2020 | JOHN JANSON |
| CofO Issued | 11/24/2020 | JOHN JANSON |
| Permit Finaled | 11/24/2020 | JOHN JANSON |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 12/3/2019 | CHRISTINE REUSCH |
| Permit | Cleared | 12/3/2019 | CHRISTINE REUSCH |
| Roof/Waste drainage to street | Cleared | 12/3/2019 | CHRISTINE REUSCH |
| Sewer availability | Cleared | 12/3/2019 | CHRISTINE REUSCH |
| Grading Pre-Inspection | Cleared | 12/9/2019 | BARTON HOLMES |
| Hydrant and Access approval | Cleared | 12/11/2019 | GEORGE SUCHAND |
| Trees in Parkway | Cleared | 12/18/2019 | JOHN KIM |
| Low Impact Development | Cleared | 12/31/2019 | JORGE MEJIA LEMUS |
| GPI Written Notices | Cleared | 1/2/2020 | RARES BODEA |
| Green Code | Cleared | 1/2/2020 | MICHAEL AYERS |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Moeini,, Soheil; Lic. No.: C84000 | 1836 PARNELL AVE 202 LOS ANGELES, CA 90025 |
Inspector Information
| GEVORK IPCHYAN, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
| TROY SANDERS, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| ELECTRICAL-Rough | 2/11/2020 | Partial Approval | JOHN KIDWELL |
| PLUMBING-Rough | 2/11/2020 | Partial Approval | JOHN KIDWELL |
| Excavation/Setback/Form/Re-Bar | 2/19/2020 | Approved | JOHN KIDWELL |
| Footing/Foundation/Slab | 2/19/2020 | Approved | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 4/3/2020 | Partial Approval | JOHN KIDWELL |
| Drywall Nailing | 4/21/2020 | Not Ready for Inspection | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 4/21/2020 | Not Ready for Inspection | JOHN KIDWELL |
| Green Building Rough | 4/21/2020 | Not Ready for Inspection | JOHN KIDWELL |
| BUILDING-Rough-Frame | 5/15/2020 | Partial Approval | JOHN KIDWELL |
| ELECTRICAL-Rough | 5/15/2020 | Not Ready for Inspection | JOHN KIDWELL |
| Green Building Rough | 5/15/2020 | Not Ready for Inspection | JOHN KIDWELL |
| HVAC-Rough | 5/15/2020 | Not Ready for Inspection | JOHN KIDWELL |
| PLUMBING-Rough | 5/15/2020 | Not Ready for Inspection | JOHN KIDWELL |
| BUILDING-Rough-Frame | 5/22/2020 | Not Ready for Inspection | JOHN KIDWELL |
| ELECTRICAL-Rough | 5/22/2020 | Approved | JOHN KIDWELL |
| Green Building Rough | 5/22/2020 | Not Ready for Inspection | JOHN KIDWELL |
| HVAC-Rough | 5/22/2020 | Not Ready for Inspection | JOHN KIDWELL |
| PLUMBING-Rough | 5/22/2020 | Not Ready for Inspection | JOHN KIDWELL |
| BUILDING-Rough-Frame | 6/12/2020 | Approved | TROY SANDERS |
| Green Building Rough | 6/12/2020 | Approved | TROY SANDERS |
| Rough-Elec/Plmb/HVAC | 6/12/2020 | Approved | TROY SANDERS |
| Interior/Exterior Lathing | 6/16/2020 | Approved | TROY SANDERS |
| Insulation | 6/24/2020 | Approved | TROY SANDERS |
| Drywall Nailing | 6/30/2020 | Approved | TROY SANDERS |
| Shower Pan | 6/30/2020 | Approved | TROY SANDERS |
| Interior/Exterior Lathing | 7/9/2020 | Approved | TROY SANDERS |
| Rough-Elec/Plmb/HVAC | 7/9/2020 | Approved | TROY SANDERS |
| ELECTRICAL-Final | 9/14/2020 | Approved | TROY SANDERS |
| Service/Power Release | 9/14/2020 | Approved | TROY SANDERS |
| ELECTRICAL-Final | 11/4/2020 | Approved | TROY SANDERS |
| Final | 11/4/2020 | Corrections Issued | TROY SANDERS |
| Green Building Final | 11/4/2020 | Approved | TROY SANDERS |
| HVAC-Final | 11/4/2020 | Approved | TROY SANDERS |
| PLUMBING-Final | 11/4/2020 | Approved | TROY SANDERS |
| SGSOV-Seismic Gas S/O Valve | 11/4/2020 | SGSOV Approved | TROY SANDERS |
| Smoke Detectors | 11/4/2020 | Approved | TROY SANDERS |
| Final | 11/23/2020 | OK to Issue CofO | TROY SANDERS |