5537 W 3RD ST 90036
Certificate Information: 5537 W 3RD ST 90036
- Application / Permit
- 19014-20000-06099
- Plan Check / Job No.
- B19VN19502
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (7) Garage - Private
- Work Description
- MAJOR REMODEL TO (E) 4-CAR GARAGE; ONLY 11'7-1/2" LONG WALL TO REMAIN TO MAKE A 31'11-1/2 X 21'11-1/2" IRREGULAR SHAPED 1ST FLOOR 2-CAR GARAGE AND A 28'5-1/2"X21'11-1/2" IRREGULAR SHAPED ADU ON THE 2ND FLOOR PER LAMC 12.22 A.33(c) and (d)
- Permit Issued
- Issued on 9/9/2021
- Issuing Office
- Current Status
- CofO Issued on 8/29/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/8/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 11/14/2019 | MARVEL DELACRUZ |
| Corrections Issued | 11/17/2019 | MARVEL DELACRUZ |
| Quality Review Completed | 11/20/2019 | GUANG MIN TUNG |
| Building Plans Picked Up | 11/20/2019 | APPLICANT |
| Applicant returned to address corrections | 9/16/2020 | MARVEL DELACRUZ |
| Green Plans Picked Up | 8/4/2021 | APPLICANT |
| Plan Check Approved | 8/16/2021 | MARVEL DELACRUZ |
| Issued | 9/9/2021 | APPLICANT |
| CofO in Progress | 8/23/2023 | ALIZAH MAYAGOITIA |
| Permit Finaled | 8/29/2023 | DEROLD HAUFF |
| CofO Issued | 8/29/2023 | DEROLD HAUFF |
| Permit Finaled | 8/29/2023 | DEROLD HAUFF |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 12/11/2019 | APEKSHYA BAJRACHARYA |
| Sewer availability | Cleared | 12/11/2019 | APEKSHYA BAJRACHARYA |
| Green Code | Cleared | 12/30/2019 | AARON COSTA |
| Construction near power lines | Cleared | 2/27/2020 | ERNEST FRESQUEZ |
| Construction within easement | Cleared | 2/27/2020 | ERNEST FRESQUEZ |
| Tenant Habitability Plan | Cleared | 7/20/2020 | PHILLIP MUNGUIA |
| Low Impact Development | Cleared | 7/29/2020 | ORVAL HERNANDEZ-MARCI |
| Roof/Waste drainage to street | Cleared | 8/7/2020 | ELAINE LEI |
| Address approval | Cleared | 10/26/2020 | THOMAS LANG |
| Construction near power lines | Cleared | 6/14/2021 | RIDWAN HARDY |
| Construction within easement | Cleared | 6/14/2021 | RIDWAN HARDY |
Contact Information
| Contractor | Ben Porat Moshe M; Lic. No.: 963181-B | P O BOX 48603 LOS ANGELES, CA 90048 |
| Engineer | Rhee,, Kyle; Lic. No.: C78215 | 2753 WAVERLY DR 403 LOS ANGELES, CA 90039 |
Inspector Information
| RONNIE MINDANAO, (213) 202-3252 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 12/10/2021 | Approved | ARTHUR SARGSYAN |
| METHANE-Barrier | 12/10/2021 | Approved | ARTHUR SARGSYAN |
| METHANE-Subgrade | 12/10/2021 | Approved | ARTHUR SARGSYAN |
| Sewer | 12/10/2021 | Approved | ARTHUR SARGSYAN |
| Masonry Wall/Backfill | 12/22/2021 | Approved | ARTHUR SARGSYAN |
| BUILDING-Rough-Frame | 1/10/2022 | Partial Approval | ARTHUR SARGSYAN |
| ELECTRICAL-Rough | 1/10/2022 | Not Ready for Inspection | ARTHUR SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 1/10/2022 | Partial Approval | ARTHUR SARGSYAN |
| Green Building Rough | 1/10/2022 | Not Ready for Inspection | ARTHUR SARGSYAN |
| METHANE-Rough | 1/10/2022 | Not Ready for Inspection | ARTHUR SARGSYAN |
| Masonry Wall/Backfill | 1/10/2022 | Approved | ARTHUR SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 1/19/2022 | Approved | ARTHUR SARGSYAN |
| BUILDING-Rough-Frame | 2/11/2022 | Corrections Issued | CRAIG DAVIS |
| Green Building Rough | 2/11/2022 | Not Ready for Inspection | CRAIG DAVIS |
| METHANE-Rough | 2/11/2022 | Corrections Issued | CRAIG DAVIS |
| Rough-Elec/Plmb/HVAC | 2/11/2022 | Corrections Issued | CRAIG DAVIS |
| ELECTRICAL-Rough | 2/24/2022 | Approved | ARTHUR SARGSYAN |
| HVAC-Rough | 2/24/2022 | Approved | ARTHUR SARGSYAN |
| Insulation | 2/24/2022 | Approved | ARTHUR SARGSYAN |
| Interior/Exterior Lathing | 2/24/2022 | Approved | ARTHUR SARGSYAN |
| PLUMBING-Rough | 2/24/2022 | Approved | ARTHUR SARGSYAN |
| Drywall Nailing | 3/11/2022 | Approved | ARTHUR SARGSYAN |
| Green Building Rough | 3/11/2022 | Approved | ARTHUR SARGSYAN |
| Interior/Exterior Lathing | 3/22/2022 | Approved | ARTHUR SARGSYAN |
| Shower Pan | 3/22/2022 | Approved | ARTHUR SARGSYAN |
| BUILDING-Rough-Frame | 6/30/2022 | Approved | ADAM ESCOTO |
| ELECTRICAL-Final | 6/30/2022 | Corrections Issued | ADAM ESCOTO |
| Final | 6/30/2022 | Corrections Issued | ADAM ESCOTO |
| Green Building Final | 6/30/2022 | Approved | ADAM ESCOTO |
| HVAC-Final | 6/30/2022 | Corrections Issued | ADAM ESCOTO |
| METHANE-Final | 6/30/2022 | Approved | ADAM ESCOTO |
| METHANE-Rough | 6/30/2022 | Approved | ADAM ESCOTO |
| PLUMBING-Final | 6/30/2022 | Approved | ADAM ESCOTO |
| SGSOV-Seismic Gas S/O Valve | 6/30/2022 | SGSOV Approved | ADAM ESCOTO |
| Smoke Detectors | 6/30/2022 | Approved | ADAM ESCOTO |
| ELECTRICAL-Final | 7/14/2022 | Approved | ALIZAH MAYAGOITIA |
| HVAC-Final | 7/14/2022 | Approved | ALIZAH MAYAGOITIA |
| Final | 8/22/2023 | OK to Issue CofO | ALIZAH MAYAGOITIA |