15423 W KADOTA ST 91342
Certificate Information: 15423 W KADOTA ST 91342
- Application / Permit
- 19014-20000-02915
- Plan Check / Job No.
- B19VN09016
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- 16'-3" X 15'-10" ADDITION TO (E) STORAGE AND CONVERT TO ACCESSORY DWELLING UNIT PER AB 494 AND SB 229. (N) 5'-4" X 5'-4" COVERED PORCH AT ENTRY. ENCLOSE 14'-8" X 5'-4" AREA OF (E) 10'-0" X 20'-0" CARPORT TO LIVING SPACE FOR ACCESSORY DWELLING UNIT. BUILDING SHALL BE EQUIPPED WITH AUTOMATIC FIRE SPRINKLER SYSTEM. "COMPLY WITH DEPARTMENT ORDER effective date 09/17/2018. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE."
- Permit Issued
- Issued on 3/11/2020
- Issuing Office
- Valley
- Current Status
- CofO Issued on 8/3/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 5/31/2019 | APPLICANT |
| Green Plans Picked Up | 7/10/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 7/11/2019 | ROSENDO MEDINA |
| Corrections Issued | 7/24/2019 | ROSENDO MEDINA |
| Quality Review Completed | 7/26/2019 | OMID HEDAYAT |
| Building Plans Picked Up | 7/30/2019 | APPLICANT |
| Plan Check Approved | 12/18/2019 | ROSENDO MEDINA |
| Issued | 3/11/2020 | LADBS |
| CofO in Progress | 7/29/2021 | MARK BEVELAQUA |
| No Progress | 7/29/2021 | MARK BEVELAQUA |
| CofO in Progress | 8/2/2021 | MARK BEVELAQUA |
| CofO Issued | 8/3/2021 | DAVID JAMES |
| Permit Finaled | 8/3/2021 | DAVID JAMES |
Permit Application Clearance Information
| Address approval | Cleared | 12/4/2019 | APEKSHYA BAJRACHARYA |
| Green Code | Cleared | 12/4/2019 | MICHAEL AYERS |
| Eng Process Fee Ord 176,300 | Cleared | 12/5/2019 | GUILLERMO PETRA |
| Sewer availability | Cleared | 12/5/2019 | GUILLERMO PETRA |
| Low Impact Development | Cleared | 12/13/2019 | RYAN HUDSON |
| Hydrant and Access approval | Cleared | 12/17/2019 | GEORGE SUCHAND |
| Roof/Waste drainage to street | Cleared | 12/17/2019 | GUILLERMO PETRA |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Rhee,, Kyle; Lic. No.: C78215 | 2753 WAVERLY DR 403 LOS ANGELES, CA 90039 |
Inspector Information
| ARA SINANIAN, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| HASANTHA WEERASEKARA, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| SCOTT SHUSTER, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| JOEL GUARDADO, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| MARIYA MIHALEVA, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| JOSE RUBIO, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| DAVID JAMES, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| DAVID HICKMAN, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| JOHN HAMILTON, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| JOHN STEPHENS, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| PIERRE VEGA, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| MARK VAN SLOOTEN, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| MICKEY YAMASHITA, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| RICHARD ROBLES, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| HAGOP BADOSSIAN, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| KIM BEAUCHAMP, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| MARK DOVICO, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| THOMAS WOODS, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| RAUL VASQUEZ, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| AUGUSTUS ALBAS, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| LEO MILBAUER, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
| MARIO CUEVAS, (818) 374-9800 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 3/13/2020 | Approved | JOHN HAMILTON |
| Pre-Inspection | 7/23/2020 | Approved | JASON BRANNON |
| Excavation/Setback/Form/Re-Bar | 7/31/2020 | Approved | JASON BRANNON |
| Floor/Roof Diaphrgm/Shear Wall | 8/7/2020 | Approved | JASON BRANNON |
| Green Building Rough | 8/7/2020 | Approved | JASON BRANNON |
| ELECTRICAL-Rough | 9/4/2020 | Approved | JASON BRANNON |
| Floor/Roof Diaphrgm/Shear Wall | 9/4/2020 | Approved | JASON BRANNON |
| HVAC-Rough | 9/4/2020 | Approved | JASON BRANNON |
| PLUMBING-Rough | 9/4/2020 | Approved | JASON BRANNON |
| Wood Frame | 9/4/2020 | Approved | JASON BRANNON |
| Interior/Exterior Lathing | 10/2/2020 | Approved | JASON BRANNON |
| ELECTRICAL-Rough | 10/28/2020 | Approved | JASON BRANNON |
| Gas Test | 10/28/2020 | Partial Approval | JASON BRANNON |
| Insulation | 10/28/2020 | Approved | JASON BRANNON |
| PLUMBING-Rough | 10/28/2020 | Approved | JASON BRANNON |
| Sewer | 10/28/2020 | Approved | JASON BRANNON |
| Underground Mechanical | 10/28/2020 | Approved | JASON BRANNON |
| Drywall Nailing | 11/4/2020 | Approved | JASON BRANNON |
| Pre-Inspection | 12/29/2020 | Corrections Issued | JAMES ABREU |
| BUILDING-Rough-Frame | 1/4/2021 | Approved | JASON BRANNON |
| Final | 1/4/2021 | Corrections Issued | JASON BRANNON |
| Footing/Foundation/Slab | 1/4/2021 | Approved | JASON BRANNON |
| Green Building Final | 1/4/2021 | Approved | JASON BRANNON |
| SGSOV-Seismic Gas S/O Valve | 1/4/2021 | SGSOV Approved | JASON BRANNON |
| Smoke Detectors | 1/4/2021 | Approved | JASON BRANNON |
| Final | 1/19/2021 | Conditional Approval | JASON BRANNON |