10891 W CHALON ROAD 90077

Certificate Information: 10891 W CHALON ROAD 90077

Application / Permit
19014-20000-00989
Plan Check / Job No.
B19VN03156
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
Remodel to (E) Single Family Dwelling to Convert (E) Dining Room to Bedroom, (E) (2) Bedrooms to Family Room, Relocate the Kitchen and Convert (E) Kitchen to Full Bathroom and closet, Remove (E) Front Porch and Add 35'-1" x 13'-2" Irregular shape to Enlarge (e) Bedroom and Add (1) 3/4 Bath and (2) Half Bath, and Add 10' x 20' attached Open Trellis.
Permit Issued
Issued on 10/7/2019
Issuing Office
Valley
Current Status
CofO Issued on 3/17/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 2/27/2019 APPLICANT
Assigned to Plan Check Engineer 3/28/2019 OMID HEDAYAT
Green Plans Picked Up 4/4/2019 APPLICANT
Corrections Issued 4/5/2019 OMID HEDAYAT
Quality Review Completed 4/8/2019 STEVEN KIM
Building Plans Picked Up 4/10/2019 APPLICANT
Applicant returned to address corrections 9/5/2019 OMID HEDAYAT
Applicant returned to address corrections 10/3/2019 OMID HEDAYAT
Plan Check Approved 10/3/2019 OMID HEDAYAT
Issued 10/7/2019 LADBS
CofO in Progress 2/9/2022 MICHAEL PELHAM
CofO in Progress 2/9/2022 MICHAEL PELHAM
Permit Finaled 3/17/2022 DANIEL ORRANTE
CofO Issued 3/17/2022 DANIEL ORRANTE
Permit Finaled 3/17/2022 DANIEL ORRANTE

Permit Application Clearance Information

GPI Written Notices Cleared 4/1/2019 OMID HEDAYAT
Eng Process Fee Ord 176,300 Cleared 5/30/2019 MARKOS PEREZ-BRAN
Roof/Waste drainage to street Cleared 5/30/2019 MARKOS PEREZ-BRAN
Sewer availability Cleared 5/30/2019 MARKOS PEREZ-BRAN
Green Code Cleared 8/29/2019 PARISA ZAHABI
Grading Pre-Inspection Cleared 10/3/2019 OMID HEDAYAT
Hydrant and Access approval Cleared 10/3/2019 GEORGE SUCHAND

Contact Information

Architect Heeb,, Derek M; Lic. No.: C32338 406 BROADWAY 222C      SANTA MONICA, CA 90401
Contractor Owner-Builder       ,
Engineer Burnazyan,, Gegam; Lic. No.: C76761 5832 JAMIESON AVE      ENCINO, CA 91316

Inspector Information

RYAN SALAZAR, (310) 914-3862 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Special/Order Compliance 2/19/2020 Order to Comply Issued GERMAN RODRIGUEZ MENDOZA
Footing/Foundation/Slab 3/5/2020 Not Ready for Inspection MATT KELLERMAN
Footing/Foundation/Slab 3/9/2020 Corrections Issued GERMAN RODRIGUEZ MENDOZA
Footing/Foundation/Slab 4/24/2020 Corrections Issued CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 4/27/2020 Partial Approval CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 5/5/2020 Not Ready for Inspection CARLOS MATAMOROS
PLUMBING-Rough 5/5/2020 Corrections Issued CARLOS MATAMOROS
BUILDING-Rough-Frame 5/7/2020 Partial Approval CHRISTOPHER WILSON
PLUMBING-Rough 5/7/2020 Partial Approval CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 5/11/2020 Partial Approval CHRISTOPHER WILSON
Insulation 5/11/2020 Partial Approval CHRISTOPHER WILSON
Underground Mechanical 5/11/2020 Partial Approval CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 5/29/2020 Partial Approval CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 7/28/2020 Corrections Issued CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 8/6/2020 Corrections Issued CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 8/14/2020 Partial Approval CHRISTOPHER WILSON
HVAC-Rough 8/17/2020 Corrections Issued GERMAN RODRIGUEZ MENDOZA
HVAC-Rough 9/2/2020 Approved CHRISTOPHER WILSON
Gas Test 9/3/2020 Approved CHRISTOPHER WILSON
PLUMBING-Rough 9/3/2020 Approved CHRISTOPHER WILSON
ELECTRICAL-Rough 9/4/2020 Corrections Issued ANTHONY MCDOWALL
ELECTRICAL-Rough 9/9/2020 Approved CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 9/10/2020 Partial Approval CHRISTOPHER WILSON
Green Building Rough 9/10/2020 Not Ready for Inspection CHRISTOPHER WILSON
Interior/Exterior Lathing 9/21/2020 Not Ready for Inspection MATT KELLERMAN
Interior/Exterior Lathing 9/24/2020 Corrections Issued CHRISTOPHER WILSON
BUILDING-Rough-Frame 9/29/2020 Approved CHRISTOPHER WILSON
Green Building Rough 9/29/2020 Approved CHRISTOPHER WILSON
Interior/Exterior Lathing 9/29/2020 Approved CHRISTOPHER WILSON
Insulation 10/6/2020 Approved CHRISTOPHER WILSON
Drywall Nailing 10/16/2020 Approved CHRISTOPHER WILSON
Interior/Exterior Lathing 10/16/2020 Approved CHRISTOPHER WILSON
Service/Power Release 1/6/2021 Approved CHRISTOPHER WILSON
Sewer 1/6/2021 Partial Approval CHRISTOPHER WILSON
Special/Order Compliance 1/9/2021 Partial Inspection CHRISTOPHER WILSON
Special/Order Compliance 1/9/2021 Partial Inspection MICHAEL PELHAM
Final 8/25/2021 Not Ready for Inspection CHRISTOPHER WILSON
Footing/Foundation/Slab 8/25/2021 Approved CHRISTOPHER WILSON
Green Building Final 8/25/2021 Not Ready for Inspection CHRISTOPHER WILSON
SGSOV-Seismic Gas S/O Valve 8/25/2021 SGSOV Approved CHRISTOPHER WILSON
Smoke Detectors 8/25/2021 Corrections Issued CHRISTOPHER WILSON
ELECTRICAL-Final 10/5/2021 Corrections Issued CHRISTOPHER WILSON
PLUMBING-Final 10/5/2021 Corrections Issued CHRISTOPHER WILSON
ELECTRICAL-Final 12/15/2021 Corrections Issued BRENDAN LOONEY
PLUMBING-Final 12/15/2021 Partial Approval BRENDAN LOONEY
ELECTRICAL-Final 2/4/2022 Approved CHRISTOPHER WILSON
Final 2/4/2022 Corrections Issued CHRISTOPHER WILSON
HVAC-Final 2/4/2022 Approved CHRISTOPHER WILSON
PLUMBING-Final 2/4/2022 Approved CHRISTOPHER WILSON
SGSOV-Seismic Gas S/O Valve 2/4/2022 SGSOV Approved CHRISTOPHER WILSON
Final 2/8/2022 OK to Issue CofO CHRISTOPHER WILSON
Green Building Final 2/8/2022 Approved CHRISTOPHER WILSON
HVAC-Final 2/8/2022 Approved CHRISTOPHER WILSON
Smoke Detectors 2/8/2022 Approved CHRISTOPHER WILSON