5901 N NAGLE AVE 91401

Certificate Information: 5901 N NAGLE AVE 91401

Application / Permit
19014-20000-00318
Plan Check / Job No.
B19VN00989
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW 36'3" X 52'9" IRREGULAR SHAPED 1ST FLOOR ADDITION TO RELOCATE KITCHEN , FAMILLY ROOM AND LAUNDRY , NEW 2' X 11' ATTACHED PATIO COVER , CONVERT (E) 17'3" X 15'6" 1ST FLOOR W.I.C AND BATHROOM TO RECREATION ROOM AND FULL BATH WITH EXTERIOR ACCESS ACCESSORY TO (E) POOL , NEW 44' X 46' IRREGULAR SHAPED 2ND FLOOR ADDITION TO CREATE (3) NEW BEDROOMS , (3) BATHROOMS, (3) CLOSETS , NEW 16'6" X 18' IRREGULAR SHAPED ATTACHED 2ND FLOOR TRELLIS , REMOVE 16'9" X 3'3" AND 28'9" X 2' FIRST FLOOR PORTIONS OF (E) SFD , INTERIOR REMODEL TO (E) SFD TO REMODEL (2) BEDROOMS . (2) BATHROOMS, CREATE NEW (2) W.I.C., NEW POWDER ROOM , NEW PANTRY, NEW MEDIA AND EQUIPMENT ROOM, NEW 11' X 5' , 5' X 16'6" AND 18' X 16'6" 2ND FLOOR BALCONIES, Re-roof with Class A roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 18 Squares ALL WORK PER ENGINEERING.
Permit Issued
Issued on 4/26/2019
Issuing Office
Valley
Current Status
CofO Issued on 4/3/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 1/22/2019 APPLICANT
Assigned to Plan Check Engineer 1/31/2019 RARES BODEA
Corrections Issued 2/3/2019 RARES BODEA
Quality Review Completed 2/5/2019 OMID HEDAYAT
Building Plans Picked Up 2/11/2019 APPLICANT
Green Plans Picked Up 2/11/2019 APPLICANT
Applicant returned to address corrections 2/22/2019 RARES BODEA
Plan Check Approved 4/23/2019 RARES BODEA
Issued 4/26/2019 LADBS
CofO in Progress 12/31/2020 BRENDAN LOONEY
Permit Finaled 4/3/2021 MICHAEL SMITH
CofO Issued 4/3/2021 MICHAEL SMITH
Permit Finaled 4/3/2021 MICHAEL SMITH

Permit Application Clearance Information

Green Code Cleared 3/18/2019 PARISA ZAHABI
Low Impact Development Cleared 3/18/2019 MITESH PATEL
Eng Process Fee Ord 176,300 Cleared 4/15/2019 GUILLERMO PETRA
Roof/Waste drainage to street Cleared 4/15/2019 GUILLERMO PETRA
Sewer availability Cleared 4/15/2019 GUILLERMO PETRA

Contact Information

Contractor Owner-Builder       ,
Engineer Sayah,, Daniel Hoshyar; Lic. No.: C67905 15233 VENTURA BLVD STE 1130      SHERMAN OAKS, CA 91403

Inspector Information

WAYNE REGESTER, (818) 374-1164 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 7/11/2019 Conditional Approval GREG ALLTON
METHANE-Barrier 7/11/2019 Approved GREG ALLTON
METHANE-Subgrade 7/11/2019 Approved GREG ALLTON
Floor/Roof Diaphrgm/Shear Wall 8/12/2019 Corrections Issued CHRISTOPHE COCHRAN
PLUMBING-Rough 8/12/2019 Partial Approval CHRISTOPHE COCHRAN
Footing/Foundation/Slab 8/16/2019 No Access for Inspection MISAEL ESPARZA
BUILDING-Rough-Frame 8/20/2019 Partial Approval GREG ALLTON
Green Building Rough 8/20/2019 Not Ready for Inspection GREG ALLTON
METHANE-Rough 8/20/2019 Approved GREG ALLTON
Floor/Roof Diaphrgm/Shear Wall 8/26/2019 Partial Approval GREG ALLTON
HVAC-Rough 11/6/2019 Partial Inspection GREG ALLTON
Floor/Roof Diaphrgm/Shear Wall 11/20/2019 Not Ready for Inspection RAUL BARAJAS
Floor/Roof Diaphrgm/Shear Wall 11/26/2019 Partial Approval GREG ALLTON
Floor/Roof Diaphrgm/Shear Wall 12/31/2019 Partial Inspection GREG ALLTON
Deputy Wood Construction 1/10/2020 Partial Approval JENNIFER RABUCHIN
Floor/Roof Diaphrgm/Shear Wall 1/10/2020 Corrections Issued MATTHEW NELSON
Special/Order Compliance 1/10/2020 Approved PIERRE VEGA
Floor/Roof Diaphrgm/Shear Wall 1/13/2020 Partial Inspection ROBERT MINASSIANS
PLUMBING-Rough 1/13/2020 Corrections Issued ROBERT MINASSIANS
HVAC-Rough 1/14/2020 Partial Inspection GREG ALLTON
PLUMBING-Rough 1/14/2020 Partial Inspection GREG ALLTON
Shower Pan 1/21/2020 Approved GREG ALLTON
Interior/Exterior Lathing 1/24/2020 Partial Approval GREG ALLTON
HVAC-Rough 1/31/2020 Not Ready for Inspection JEFFREY PARD
PLUMBING-Rough 1/31/2020 Approved JEFFREY PARD
ELECTRICAL-Rough 2/19/2020 Approved RAYMOND KEHOE
HVAC-Rough 2/19/2020 Approved RAYMOND KEHOE
PLUMBING-Rough 2/19/2020 Approved RAYMOND KEHOE
Insulation 3/2/2020 Approved GREG ALLTON
Interior/Exterior Lathing 3/4/2020 Approved GREG ALLTON
Drywall Nailing 3/18/2020 Approved GREG ALLTON
Green Building Rough 3/18/2020 Approved GREG ALLTON
BUILDING-Rough-Frame 12/23/2020 Approved BRENDAN LOONEY
Final 12/23/2020 Corrections Issued BRENDAN LOONEY
Footing/Foundation/Slab 12/23/2020 Approved BRENDAN LOONEY
Green Building Final 12/23/2020 Not Ready for Inspection BRENDAN LOONEY
SGSOV-Seismic Gas S/O Valve 12/23/2020 SGSOV Approved BRENDAN LOONEY
Smoke Detectors 12/23/2020 Approved BRENDAN LOONEY
Final 12/31/2020 OK to Issue CofO BRENDAN LOONEY
Green Building Final 12/31/2020 Approved BRENDAN LOONEY