5601 N ANDASOL AVE 91316
Certificate Information: 5601 N ANDASOL AVE 91316
- Application / Permit
- 19014-10000-06556
- Plan Check / Job No.
- B19LA25445
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- ADDITION TO (E) 2-CAR GARAGE AND CONVERT INTO ACCESSORY DWELLING UNIT PER AB-494 &SB-229. All Work Per Engineer Design
- Permit Issued
- Issued on 7/28/2020
- Issuing Office
- Current Status
- CofO Issued on 10/25/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/3/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 12/26/2019 | ZAW HAN |
| Corrections Issued | 1/2/2020 | ZAW HAN |
| Quality Review Completed | 1/9/2020 | HERNAN ARREOLA |
| Building Plans Picked Up | 1/10/2020 | APPLICANT |
| Green Plans Picked Up | 4/22/2020 | APPLICANT |
| Applicant returned to address corrections | 6/2/2020 | ZAW HAN |
| Plan Check Approved | 6/11/2020 | ZAW HAN |
| Issued | 7/28/2020 | APPLICANT |
| CofO in Progress | 8/26/2021 | STEVEN BACK |
| CofO Issued | 10/25/2021 | MICHAEL SMITH |
| Permit Finaled | 10/25/2021 | MICHAEL SMITH |
Permit Application Clearance Information
| Address approval | Cleared | 1/31/2020 | JUAN ASHTON |
| ZI | Cleared | 1/31/2020 | SARAHI ORTEGA |
| Low Impact Development | Cleared | 2/26/2020 | SARAH YOUSSEF |
| Green Code | Cleared | 2/27/2020 | ZAW HAN |
| Eng Process Fee Ord 176,300 | Cleared | 3/2/2020 | EMIL KYUPELYAN |
| Permit | Cleared | 3/2/2020 | EMIL KYUPELYAN |
| Roof/Waste drainage to street | Cleared | 3/2/2020 | EMIL KYUPELYAN |
| Sewer availability | Cleared | 3/2/2020 | EMIL KYUPELYAN |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Tuchscher,, James Todd; Lic. No.: C77649 | 5503 E 2ND ST LONG BEACH, CA 90803 |
Inspector Information
| JON MCHUGH, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
| IVAN SARABIA, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 8/24/2020 | Partial Approval | STEVEN BACK |
| Footing/Foundation/Slab | 9/1/2020 | Approved | STEVEN BACK |
| Deputy Reinf. Concrete | 9/3/2020 | Partial Approval | STEVEN BACK |
| Deputy Drilled-In Anchors | 9/25/2020 | Approved | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 10/20/2020 | Corrections Issued | STEVEN BACK |
| BUILDING-Rough-Frame | 12/29/2020 | Not Ready for Inspection | VINCENT HANLEY |
| Floor/Roof Diaphrgm/Shear Wall | 12/29/2020 | Not Ready for Inspection | VINCENT HANLEY |
| Green Building Rough | 12/29/2020 | Not Ready for Inspection | VINCENT HANLEY |
| MERV13>=Rough | 12/29/2020 | Not Ready for Inspection | VINCENT HANLEY |
| PLUMBING-Rough | 1/19/2021 | Corrections Issued | BRENDAN LOONEY |
| ELECTRICAL-Rough | 1/22/2021 | Not Ready for Inspection | JOSEPH SAGEN |
| HVAC-Rough | 1/22/2021 | Not Ready for Inspection | JOSEPH SAGEN |
| PLUMBING-Rough | 1/22/2021 | Not Ready for Inspection | JOSEPH SAGEN |
| ELECTRICAL-Rough | 1/28/2021 | Approved | VINCENT HANLEY |
| Floor/Roof Diaphrgm/Shear Wall | 1/28/2021 | Approved | VINCENT HANLEY |
| PLUMBING-Rough | 1/28/2021 | Approved | VINCENT HANLEY |
| Green Building Rough | 2/3/2021 | Approved | STEVEN BACK |
| HVAC-Rough | 2/3/2021 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 2/3/2021 | Partial Approval | STEVEN BACK |
| BUILDING-Rough-Frame | 2/5/2021 | Approved | STEVEN BACK |
| MERV13>=Rough | 2/5/2021 | Approved | STEVEN BACK |
| Shower Pan | 2/5/2021 | Approved | STEVEN BACK |
| Insulation | 2/16/2021 | Approved | STEVEN BACK |
| Drywall Nailing | 2/24/2021 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 2/24/2021 | Not Ready for Inspection | STEVEN BACK |
| Interior/Exterior Lathing | 3/2/2021 | Approved | STEVEN BACK |
| Gas Test | 6/22/2021 | Approved | STEVEN BACK |
| HVAC-Final | 6/22/2021 | Corrections Issued | STEVEN BACK |
| PLUMBING-Final | 6/22/2021 | Approved | STEVEN BACK |
| SGSOV-Seismic Gas S/O Valve | 6/22/2021 | SGSOV Approved | STEVEN BACK |
| ELECTRICAL-Final | 6/23/2021 | Corrections Issued | STEVEN BACK |
| ELECTRICAL-Final | 8/17/2021 | Not Ready for Inspection | STEVEN BACK |
| Final | 8/17/2021 | Corrections Issued | STEVEN BACK |
| Green Building Final | 8/17/2021 | Approved | STEVEN BACK |
| HVAC-Final | 8/17/2021 | Approved | STEVEN BACK |
| MERV13>=Final | 8/17/2021 | Approved | STEVEN BACK |
| Smoke Detectors | 8/17/2021 | Approved | STEVEN BACK |
| Final | 8/20/2021 | Not Ready for Inspection | STEVEN BACK |
| ELECTRICAL-Final | 8/26/2021 | Approved | STEVEN BACK |
| Final | 8/26/2021 | OK to Issue CofO | STEVEN BACK |