7110 S HOOVER ST 90044
Certificate Information: 7110 S HOOVER ST 90044
- Application / Permit
- 19010-70000-04880
- Plan Check / Job No.
- B19SL01534
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 2 STORY SINGLE FAMILY DWELLING WITH ATTACHED GARAGE AT FRONT OF LOT. “Contractor will perform both demo and new construction onsite”
- Permit Issued
- Issued on 9/3/2021
- Issuing Office
- Metro
- Current Status
- CofO Issued on 5/28/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/1/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 11/7/2019 | PRANITA SHAH |
| Green Plans Picked Up | 11/21/2019 | APPLICANT |
| Corrections Issued | 11/26/2019 | PRANITA SHAH |
| Quality Review Completed | 12/4/2019 | TU HUA |
| Building Plans Picked Up | 12/5/2019 | APPLICANT |
| Applicant returned to address corrections | 5/22/2020 | PRANITA SHAH |
| Applicant returned to address corrections | 6/4/2020 | PRANITA SHAH |
| Applicant returned to address corrections | 6/30/2020 | PRANITA SHAH |
| Applicant returned to address corrections | 7/31/2020 | PRANITA SHAH |
| Plan Check Approved | 8/14/2020 | PRANITA SHAH |
| Issued | 9/3/2021 | APPLICANT |
| CofO in Progress | 5/17/2023 | MICHAEL LEWIS |
| No Progress | 5/23/2023 | DEROLD HAUFF |
| CofO in Progress | 5/25/2023 | CHARLES BOGHOSKHAN |
| Permit Finaled | 5/28/2023 | DEROLD HAUFF |
| CofO Issued | 5/28/2023 | DEROLD HAUFF |
| Permit Finaled | 5/28/2023 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 12/19/2019 | THOMAS LANG |
| Green Code | Cleared | 1/21/2020 | KHEDER ALRAZAA |
| Eng Process Fee Ord 176,300 | Cleared | 2/20/2020 | JEANETTE VONG |
| Hydrant and Access approval | Cleared | 2/20/2020 | ROBERT DUFF |
| Sewer availability | Cleared | 2/20/2020 | JEANETTE VONG |
| ZI | Cleared | 2/25/2020 | HELEN JADALI |
| Highway dedication | Cleared | 3/17/2020 | CELINA MORENO |
| Low Impact Development | Cleared | 3/17/2020 | MARTIN FRAGOSO |
| Roof/Waste drainage to street | Cleared | 5/28/2020 | CECILIO NAVARRO |
Contact Information
| Contractor | Baksh Construction Inc; Lic. No.: 910533-B | 4 HILLCREST MANOR ROLLING HILLS ESTATES, CA 90274 |
| Engineer | Nuno,, Arnulfo; Lic. No.: C88425 | 7057 DWIGHT WAY SAN BERNARDINO, CA 92404 |
Inspector Information
| BARRY HACHE, (213) 202-9851 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 10/12/2021 | Approved | HORACE FULTZ |
| Insulation | 10/29/2021 | Not Ready for Inspection | ALEJANDRO DE ARTOLA |
| Underground Mechanical | 10/29/2021 | Corrections Issued | ALEJANDRO DE ARTOLA |
| Wood Frame | 10/29/2021 | Corrections Issued | ALEJANDRO DE ARTOLA |
| Insulation | 11/1/2021 | Partial Approval | HORACE FULTZ |
| Underground Mechanical | 11/1/2021 | Approved | HORACE FULTZ |
| Wood Frame | 11/1/2021 | Partial Approval | HORACE FULTZ |
| Floor/Roof Diaphrgm/Shear Wall | 11/3/2021 | Partial Approval | HORACE FULTZ |
| Floor/Roof Diaphrgm/Shear Wall | 11/18/2021 | Partial Approval | HORACE FULTZ |
| Floor/Roof Diaphrgm/Shear Wall | 12/22/2021 | Partial Approval | HORACE FULTZ |
| BUILDING-Rough-Frame | 6/28/2022 | Not Ready for Inspection | SABAS ALONSO |
| ELECTRICAL-Final | 6/28/2022 | Corrections Issued | SABAS ALONSO |
| ELECTRICAL-Rough | 6/28/2022 | Corrections Issued | SABAS ALONSO |
| Green Building Rough | 6/28/2022 | Approved | SABAS ALONSO |
| HVAC-Rough | 6/28/2022 | Approved | SABAS ALONSO |
| PLUMBING-Rough | 6/28/2022 | Corrections Issued | SABAS ALONSO |
| Rough-Elec/Plmb/HVAC | 6/28/2022 | Partial Approval | SABAS ALONSO |
| Verify Sprinkler Sign Off | 6/28/2022 | Not Ready for Inspection | SABAS ALONSO |
| Rough-Elec/Plmb/HVAC | 6/30/2022 | Approved | HORACE FULTZ |
| Drywall Nailing | 7/11/2022 | Approved | HORACE FULTZ |
| Interior/Exterior Lathing | 7/11/2022 | Approved | HORACE FULTZ |
| BUILDING-Rough-Frame | 3/2/2023 | Approved | HORACE FULTZ |
| ELECTRICAL-Final | 3/2/2023 | Approved | HORACE FULTZ |
| Final | 3/2/2023 | Conditional Approval | HORACE FULTZ |
| Green Building Final | 3/2/2023 | Approved | HORACE FULTZ |
| HVAC-Final | 3/2/2023 | Approved | HORACE FULTZ |
| PLUMBING-Final | 3/2/2023 | Approved | HORACE FULTZ |
| SGSOV-Seismic Gas S/O Valve | 3/2/2023 | SGSOV Approved | HORACE FULTZ |
| Service/Power Release | 3/2/2023 | Approved | HORACE FULTZ |
| Smoke Detectors | 3/2/2023 | Approved | HORACE FULTZ |
| Verify Sprinkler Sign Off | 3/2/2023 | Approved | HORACE FULTZ |
| Final | 5/16/2023 | OK to Issue CofO | MICHAEL LEWIS |