13980 W AUBREY ROAD 90210
Certificate Information: 13980 W AUBREY ROAD 90210
- Application / Permit
- 19010-30000-02650
- Plan Check / Job No.
- B19WL03449
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 2-STORY SINGLE FAMILY DWELLING WITH ATTACHED GARAGE.
- Permit Issued
- Issued on 2/10/2020
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 10/29/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/20/2019 | APPLICANT |
| Green Plans Picked Up | 7/10/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 7/18/2019 | SAMUEL GONZALEZ |
| Corrections Issued | 7/22/2019 | SAMUEL GONZALEZ |
| Quality Review Completed | 7/24/2019 | QUAN NGHIEM |
| Building Plans Picked Up | 7/31/2019 | APPLICANT |
| Plan Check Approved | 11/14/2019 | SAMUEL GONZALEZ |
| No Progress | 11/14/2019 | SAMUEL GONZALEZ |
| Plan Check Approved | 11/14/2019 | SAMUEL GONZALEZ |
| Issued | 2/10/2020 | LADBS |
| CofO in Progress | 10/13/2022 | MISAEL ESPARZA |
| Permit Finaled | 10/29/2022 | MICHAEL SMITH |
| CofO Issued | 10/29/2022 | MICHAEL SMITH |
| Permit Finaled | 10/29/2022 | MICHAEL SMITH |
Permit Application Clearance Information
| BHO/Hillside ordinance | Cleared | 9/9/2019 | ERIK BEASLEY |
| BHO/Hillside ordinance | Cleared | 9/9/2019 | ERIK BEASLEY |
| BHO/Hillside ordinance | Cleared | 9/9/2019 | ERIK BEASLEY |
| Eng Process Fee Ord 176,300 | Cleared | 9/9/2019 | ERIK BEASLEY |
| Hydrant and Access approval | Cleared | 9/9/2019 | ROBERT DUFF |
| Permit | Cleared | 9/9/2019 | ERIK BEASLEY |
| Sewer availability | Cleared | 9/9/2019 | ERIK BEASLEY |
| ZA Case | Cleared | 9/10/2019 | SARAH GOLDMAN |
| ZA Case | Cleared | 9/10/2019 | SARAH GOLDMAN |
| Specific Plan | Cleared | 10/4/2019 | VALENTINA KNOX |
| Green Code | Cleared | 10/17/2019 | DONALD CRICHLOW |
| Low Impact Development | Cleared | 10/24/2019 | MARTIN FRAGOSO |
| Trees in Parkway | Cleared | 10/24/2019 | JOHN KIM |
| GPI Written Notices | Cleared | 11/14/2019 | SAMUEL GONZALEZ |
| Grading Pre-Inspection | Cleared | 11/14/2019 | SAMUEL GONZALEZ |
| Roof/Waste drainage to street | Cleared | 11/14/2019 | EMIL KYUPELYAN |
Contact Information
| Architect | De, Angelis, David John; Lic. No.: C31202 | 3338 MILLS AVENUE LA CRESCENTA, CA 91011 |
| Contractor | Drexel Construction Management Llc; Lic. No.: 1014160-B | 6380 WILSHIRE BLVD #1018 LOS ANGELES, CA 90048 |
Inspector Information
| MISAEL ESPARZA, (818) 374-1169 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 4/22/2020 | Corrections Issued | DAVID SANDOVAL |
| Footing/Foundation/Slab | 4/27/2020 | Approved | TROY SANDERS |
| Excavation/Setback/Form/Re-Bar | 5/15/2020 | Approved | CHARLES POWELL |
| BUILDING-Rough-Frame | 6/12/2020 | Corrections Issued | CHARLES POWELL |
| Green Building Rough | 6/12/2020 | Not Ready for Inspection | CHARLES POWELL |
| Underground Mechanical | 6/12/2020 | Partial Approval | CHARLES POWELL |
| Verify Sprinkler Sign Off | 6/12/2020 | Not Ready for Inspection | CHARLES POWELL |
| Wood Frame | 6/16/2020 | Partial Approval | CHARLES POWELL |
| Floor/Roof Diaphrgm/Shear Wall | 6/19/2020 | Corrections Issued | CHARLES POWELL |
| Floor/Roof Diaphrgm/Shear Wall | 6/22/2020 | Partial Approval | CHARLES POWELL |
| Special/Order Compliance | 6/22/2020 | Approved | CHARLES POWELL |
| Excavation/Setback/Form/Re-Bar | 7/10/2020 | Approved | CHARLES POWELL |
| Floor/Roof Diaphrgm/Shear Wall | 7/24/2020 | Partial Approval | CHARLES POWELL |
| BUILDING-Rough-Frame | 8/24/2020 | Not Ready for Inspection | CHARLES POWELL |
| Green Building Rough | 8/24/2020 | Not Ready for Inspection | CHARLES POWELL |
| Verify Sprinkler Sign Off | 8/24/2020 | Not Ready for Inspection | CHARLES POWELL |
| PLUMBING-Rough | 11/5/2020 | Approved | CHARLES POWELL |
| Shower Pan | 11/5/2020 | Not Ready for Inspection | CHARLES POWELL |
| ELECTRICAL-Rough | 11/13/2020 | Not Ready for Inspection | CHARLES POWELL |
| Floor/Roof Diaphrgm/Shear Wall | 11/13/2020 | Corrections Issued | CHARLES POWELL |
| Sewer | 11/13/2020 | Not Ready for Inspection | CHARLES POWELL |
| ELECTRICAL-Rough | 11/19/2020 | Partial Approval | CHARLES POWELL |
| Floor/Roof Diaphrgm/Shear Wall | 11/19/2020 | Partial Approval | CHARLES POWELL |
| HVAC-Rough | 11/19/2020 | Approved | CHARLES POWELL |
| Sewer | 11/19/2020 | Approved | CHARLES POWELL |
| Shower Pan | 11/19/2020 | Approved | CHARLES POWELL |
| BUILDING-Rough-Frame | 12/7/2020 | Corrections Issued | CHARLES POWELL |
| Green Building Rough | 12/7/2020 | Not Ready for Inspection | CHARLES POWELL |
| Interior/Exterior Lathing | 12/7/2020 | Partial Approval | CHARLES POWELL |
| Verify Sprinkler Sign Off | 12/7/2020 | Approved | CHARLES POWELL |
| Green Building Rough | 12/29/2020 | Approved | BRENDAN LOONEY |
| Insulation | 1/11/2021 | Partial Approval | CHARLES POWELL |
| Insulation | 1/15/2021 | Approved | CHARLES POWELL |
| Drywall Nailing | 1/25/2021 | Approved | ARAM AVEDISIAN |
| ELECTRICAL-Final | 3/16/2022 | Corrections Issued | MISAEL ESPARZA |
| HVAC-Final | 3/16/2022 | Corrections Issued | MISAEL ESPARZA |
| Service/Power Release | 3/16/2022 | Not Ready for Inspection | MISAEL ESPARZA |
| Smoke Detectors | 3/16/2022 | Corrections Issued | MISAEL ESPARZA |
| ELECTRICAL-Final | 6/29/2022 | Partial Approval | HERBERT GIRON |
| HVAC-Final | 6/29/2022 | Not Ready for Inspection | HERBERT GIRON |
| BUILDING-Rough-Frame | 7/20/2022 | Approved | MISAEL ESPARZA |
| ELECTRICAL-Final | 7/20/2022 | Partial Approval | MISAEL ESPARZA |
| Final | 7/20/2022 | Corrections Issued | MISAEL ESPARZA |
| Green Building Final | 7/20/2022 | Approved | MISAEL ESPARZA |
| HVAC-Final | 7/20/2022 | Corrections Issued | MISAEL ESPARZA |
| PLUMBING-Final | 7/20/2022 | Corrections Issued | MISAEL ESPARZA |
| SGSOV-Seismic Gas S/O Valve | 7/20/2022 | SGSOV Not Ready | MISAEL ESPARZA |
| Service/Power Release | 7/20/2022 | Not Ready for Inspection | MISAEL ESPARZA |
| Smoke Detectors | 7/20/2022 | Approved | MISAEL ESPARZA |
| ELECTRICAL-Final | 7/27/2022 | Approved | MISAEL ESPARZA |
| Service/Power Release | 7/27/2022 | Corrections Issued | MISAEL ESPARZA |
| HVAC-Final | 7/29/2022 | Corrections Issued | MISAEL ESPARZA |
| PLUMBING-Final | 7/29/2022 | Corrections Issued | MISAEL ESPARZA |
| Gas Test | 8/11/2022 | Not Ready for Inspection | MISAEL ESPARZA |
| HVAC-Final | 8/11/2022 | Conditional Approval | MISAEL ESPARZA |
| PLUMBING-Final | 8/11/2022 | Approved | MISAEL ESPARZA |
| Final | 10/12/2022 | OK to Issue CofO | MISAEL ESPARZA |
| HVAC-Final | 10/12/2022 | Approved | MISAEL ESPARZA |
| SGSOV-Seismic Gas S/O Valve | 10/12/2022 | SGSOV Approved | MISAEL ESPARZA |
| Service/Power Release | 10/12/2022 | Approved | MISAEL ESPARZA |