469 1/2 N SWEETZER AVE 90048
Certificate Information: 469 1/2 N SWEETZER AVE 90048
- Application / Permit
- 19010-20001-01720
- Plan Check / Job No.
- B20VN06270
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- Supplement to permit 19010-20000-01720 to add ADU over proposed garage, max. 16'-H,
- Permit Issued
- Issued on 8/6/2020
- Issuing Office
- Current Status
- Permit Finaled on 7/31/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 5/4/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 5/4/2020 | CHON CHIO KUO |
| Corrections Issued | 5/14/2020 | CHON CHIO KUO |
| Applicant returned to address corrections | 7/6/2020 | CHON CHIO KUO |
| Plan Check Approved | 7/14/2020 | CHON CHIO KUO |
| Issued | 8/6/2020 | APPLICANT |
| Permit Finaled | 7/28/2021 | CHRIS CHRISTENSEN |
| Permit Finaled | 7/30/2021 | CHRIS CHRISTENSEN |
Permit Application Clearance Information
| Green Code | Cleared | 5/13/2020 | MICHAEL AYERS |
| Address approval | Cleared | 5/20/2020 | JEANIE LAM |
| Roof/Waste drainage to street | Cleared | 5/20/2020 | JEANIE LAM |
| Eng Process Fee Ord 176,300 | Cleared | 5/21/2020 | JEANIE LAM |
| Sewer availability | Cleared | 5/21/2020 | JEANIE LAM |
| Hydrant and Access approval | Cleared | 6/1/2020 | KURT CORRAL |
| Construction near power lines | Cleared | 6/27/2020 | RIDWAN HARDY |
Contact Information
| Architect | Jewett,, Britton Lee; Lic. No.: C20622 | 112 E. DE LA GUERRA, #7 SANTA BARBARA, CA 93101 |
| Contractor | Owner-Builder | , |
| Engineer | Abkarian,, Raffi; Lic. No.: C36027 | 18763 VINTAGE STREET NORTHRIDGE, CA 91324 |
| Engineer | Minas,, Caro Jolfaie; Lic. No.: GE601 | 4742 SAN FERNANDO RD GLENDALE, CA 91204 |
Inspector Information
| JOSE MACIAS, (213) 202-3125 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 11/5/2020 | Approved | CHRIS CHRISTENSEN |
| Underground Mechanical | 11/5/2020 | Approved | CHRIS CHRISTENSEN |
| Floor/Roof Diaphrgm/Shear Wall | 11/17/2020 | Conditional Approval | CHRIS CHRISTENSEN |
| Floor/Roof Diaphrgm/Shear Wall | 12/21/2020 | Partial Approval | CHRIS CHRISTENSEN |
| Wood Frame | 12/21/2020 | Partial Approval | CHRIS CHRISTENSEN |
| Green Building Rough | 1/22/2021 | Not Ready for Inspection | CHRIS CHRISTENSEN |
| Rough-Elec/Plmb/HVAC | 1/22/2021 | Approved | CHRIS CHRISTENSEN |
| BUILDING-Rough-Frame | 2/2/2021 | Approved | CHRIS CHRISTENSEN |
| Green Building Rough | 2/2/2021 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 2/2/2021 | Partial Approval | CHRIS CHRISTENSEN |
| METHANE-Rough | 2/2/2021 | Approved | CHRIS CHRISTENSEN |
| Verify Sprinkler Sign Off | 2/2/2021 | Approved | CHRIS CHRISTENSEN |
| Insulation | 2/10/2021 | Approved | CHRIS CHRISTENSEN |
| Drywall Nailing | 2/17/2021 | Approved | CHRIS CHRISTENSEN |
| Gas Test | 2/17/2021 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 3/2/2021 | Partial Approval | CHRIS CHRISTENSEN |
| Underground Mechanical | 3/2/2021 | Partial Approval | CHRIS CHRISTENSEN |
| ELECTRICAL-Final | 6/9/2021 | Approved | CHRIS CHRISTENSEN |
| Service/Power Release | 6/9/2021 | Approved | CHRIS CHRISTENSEN |
| Smoke Detectors | 6/9/2021 | Approved | CHRIS CHRISTENSEN |
| PLUMBING-Final | 7/14/2021 | Corrections Issued | CHRIS CHRISTENSEN |
| Green Building Final | 7/16/2021 | Approved | CHRIS CHRISTENSEN |
| HVAC-Final | 7/16/2021 | Approved | CHRIS CHRISTENSEN |
| PLUMBING-Final | 7/16/2021 | Approved | CHRIS CHRISTENSEN |
| Final | 7/28/2021 | Permit Finaled | CHRIS CHRISTENSEN |
| Footing/Foundation/Slab | 7/28/2021 | Approved | CHRIS CHRISTENSEN |
| METHANE-Barrier | 7/28/2021 | Approved | CHRIS CHRISTENSEN |
| METHANE-Subgrade | 7/28/2021 | Approved | CHRIS CHRISTENSEN |
| Final | 7/30/2021 | Permit Finaled | CHRIS CHRISTENSEN |
| Verify Rec and Parks Fee Memo | 7/30/2021 | Approved | CHRIS CHRISTENSEN |