626-626 1/2 W 83RD ST 90044
Certificate Information: 626-626 1/2 W 83RD ST 90044
- Application / Permit
- 19010-20000-05985
- Plan Check / Job No.
- B19VN22279
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (2) Duplex
- Work Description
- NEW 43' 6" X 23' 3-STORY DUPLEX WITH (2) ATTACHED 1-CAR GARAGES. ALL WORK DONE PER STRUCTURAL ENGINEERING. NFPA 13D FIRE SPRINKLERS TO BE PROVIDED.
- Permit Issued
- Issued on 8/16/2021
- Issuing Office
- Current Status
- CofO Issued on 2/19/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/23/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 1/2/2020 | GURUNATH NESARAJAH |
| Corrections Issued | 1/5/2020 | GURUNATH NESARAJAH |
| Quality Review Completed | 1/10/2020 | GUANG MIN TUNG |
| Green Plans Picked Up | 1/10/2020 | APPLICANT |
| Applicant returned to address corrections | 6/9/2021 | GURUNATH NESARAJAH |
| Applicant returned to address corrections | 7/8/2021 | GURUNATH NESARAJAH |
| Building Plans Picked Up | 7/13/2021 | APPLICANT |
| Plan Check Approved | 8/3/2021 | GURUNATH NESARAJAH |
| Issued | 8/16/2021 | APPLICANT |
| CofO in Progress | 2/16/2023 | LILIANA PORTILLO |
| Permit Finaled | 2/19/2023 | DEROLD HAUFF |
| CofO Issued | 2/19/2023 | DEROLD HAUFF |
| Permit Finaled | 2/19/2023 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 1/14/2020 | ERIK BEASLEY |
| Eng Process Fee Ord 176,300 | Cleared | 1/14/2020 | ERIK BEASLEY |
| Sewer availability | Cleared | 1/14/2020 | ERIK BEASLEY |
| Green Code | Cleared | 10/14/2020 | MICHAEL AYERS |
| Hydrant and Access approval | Cleared | 12/1/2020 | MATTHEW CRAIG |
| Low Impact Development | Cleared | 4/12/2021 | ORVAL HERNANDEZ-MARCI |
| Roof/Waste drainage to street | Cleared | 4/16/2021 | ROSA SILVA |
Contact Information
| Contractor | Aardvark Group Inc The; Lic. No.: 762498-B | 13337 SOUTH STREET # 134 CERRITOS, CA 90703 |
| Engineer | Dorta,, Michael Rohrs; Lic. No.: C72538 | 26851 GRAYSLAKE ROAD RANCHO PALOS VERDES, CA 90275 |
Inspector Information
| JOHN QUINTANILLA, (213) 792-6055 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 2/15/2022 | Partial Approval | LILIANA PORTILLO |
| Footing/Foundation/Slab | 2/25/2022 | Approved | STUART CHAPMAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/12/2022 | Partial Approval | LILIANA PORTILLO |
| Floor/Roof Diaphrgm/Shear Wall | 5/25/2022 | Partial Approval | LILIANA PORTILLO |
| HVAC-Rough | 8/8/2022 | Not Ready for Inspection | LILIANA PORTILLO |
| Deputy Wood Construction | 9/1/2022 | Conditional Approval | ALEJANDRO DE ARTOLA |
| Floor/Roof Diaphrgm/Shear Wall | 9/7/2022 | Approved | LILIANA PORTILLO |
| PLUMBING-Rough | 9/7/2022 | Corrections Issued | LILIANA PORTILLO |
| ELECTRICAL-Rough | 9/12/2022 | Corrections Issued | LILIANA PORTILLO |
| HVAC-Rough | 9/12/2022 | Corrections Issued | LILIANA PORTILLO |
| BUILDING-Rough-Frame | 9/14/2022 | Conditional Approval | LILIANA PORTILLO |
| ELECTRICAL-Rough | 9/14/2022 | Conditional Approval | LILIANA PORTILLO |
| HVAC-Rough | 9/14/2022 | Approved | LILIANA PORTILLO |
| PLUMBING-Rough | 9/14/2022 | Approved | LILIANA PORTILLO |
| Verify Sprinkler Sign Off | 9/14/2022 | Approved | LILIANA PORTILLO |
| BUILDING-Rough-Frame | 9/26/2022 | Approved | LILIANA PORTILLO |
| ELECTRICAL-Rough | 9/26/2022 | Approved | LILIANA PORTILLO |
| Green Building Rough | 9/26/2022 | Approved | LILIANA PORTILLO |
| Insulation | 9/26/2022 | Approved | LILIANA PORTILLO |
| Interior/Exterior Lathing | 9/26/2022 | Partial Approval | LILIANA PORTILLO |
| Drywall Nailing | 10/5/2022 | Corrections Issued | LILIANA PORTILLO |
| ELECTRICAL-Final | 1/4/2023 | Corrections Issued | MICHAEL LEWIS |
| Gas Test | 1/4/2023 | Corrections Issued | MICHAEL LEWIS |
| HVAC-Final | 1/4/2023 | Approved | MICHAEL LEWIS |
| Drywall Nailing | 1/12/2023 | Approved | LILIANA PORTILLO |
| ELECTRICAL-Final | 1/12/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| Final | 1/12/2023 | Corrections Issued | LILIANA PORTILLO |
| Gas Test | 1/12/2023 | Approved | LILIANA PORTILLO |
| Green Building Final | 1/12/2023 | Corrections Issued | LILIANA PORTILLO |
| PLUMBING-Final | 1/12/2023 | Approved | LILIANA PORTILLO |
| SGSOV-Seismic Gas S/O Valve | 1/12/2023 | SGSOV Not Ready | LILIANA PORTILLO |
| Service/Power Release | 1/12/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| Smoke Detectors | 1/12/2023 | Corrections Issued | LILIANA PORTILLO |
| ELECTRICAL-Final | 1/25/2023 | Corrections Issued | LILIANA PORTILLO |
| Final | 1/25/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| Green Building Final | 1/25/2023 | Approved | LILIANA PORTILLO |
| HVAC-Final | 1/25/2023 | Approved | LILIANA PORTILLO |
| PLUMBING-Final | 1/25/2023 | Approved | LILIANA PORTILLO |
| SGSOV-Seismic Gas S/O Valve | 1/25/2023 | SGSOV Approved | LILIANA PORTILLO |
| Service/Power Release | 1/25/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| Smoke Detectors | 1/25/2023 | Approved | LILIANA PORTILLO |
| ELECTRICAL-Final | 2/9/2023 | Approved | LILIANA PORTILLO |
| Final | 2/9/2023 | Conditional Approval | LILIANA PORTILLO |
| Service/Power Release | 2/9/2023 | Approved | LILIANA PORTILLO |