23270 W GONZALES DR 91367
Certificate Information: 23270 W GONZALES DR 91367
- Application / Permit
- 19010-20000-05467
- Plan Check / Job No.
- B19VN21147
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW (82'-4"x 59'-6") TWO-STORY SINGLE FAMILY DWELLING WITH ATT 2-CAR GARAGE AND TRELLIS PATIO, NFPA-13D AUTOMATIC FIRE SPRINKLER THROUGHOUT. WORK PER ENGINEER.
- Permit Issued
- Issued on 10/15/2021
- Issuing Office
- Current Status
- CofO Issued on 11/4/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/5/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 1/2/2020 | TROY DEGUZMAN |
| Green Plans Picked Up | 1/2/2020 | APPLICANT |
| Corrections Issued | 1/9/2020 | TROY DEGUZMAN |
| Quality Review Completed | 1/13/2020 | CHON CHIO KUO |
| Building Plans Picked Up | 1/13/2020 | APPLICANT |
| Applicant returned to address corrections | 10/1/2021 | TROY DEGUZMAN |
| Plan Check Approved | 10/15/2021 | TROY DEGUZMAN |
| Issued | 10/15/2021 | APPLICANT |
| CofO in Progress | 11/3/2022 | TROY SANDERS |
| Permit Finaled | 11/4/2022 | JOHN JANSON |
| CofO Issued | 11/4/2022 | JOHN JANSON |
| Permit Finaled | 11/4/2022 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 4/1/2021 | GUILLERMO PETRA |
| Eng Process Fee Ord 176,300 | Cleared | 5/24/2021 | LEE GUILBEAUX |
| Permit | Cleared | 5/24/2021 | LEE GUILBEAUX |
| Sewer availability | Cleared | 5/24/2021 | LEE GUILBEAUX |
| GPI Written Notices | Cleared | 6/4/2021 | TROY DEGUZMAN |
| Grading Pre-Inspection | Cleared | 6/4/2021 | TROY DEGUZMAN |
| Trees in Parkway | Cleared | 6/8/2021 | JOHN KIM |
| Hydrant and Access approval | Cleared | 7/16/2021 | MATTHEW CRAIG |
| Construction near power lines | Cleared | 8/27/2021 | RIDWAN HARDY |
| Low Impact Development | Cleared | 9/5/2021 | JORGE MEJIA LEMUS |
| Roof/Waste drainage to street | Cleared | 9/10/2021 | ABDULLAH SADOZAI |
| Disturb/Remove Protected Trees | Cleared | 9/15/2021 | TROY DEGUZMAN |
| Green Code | Cleared | 10/4/2021 | MICHAEL AYERS |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Khansa,, Eyass Wafik; Lic. No.: C91758 | 2252 JOSIE AVE LONG BEACH, CA 90815 |
Inspector Information
| GEVORK IPCHYAN, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
| TROY SANDERS, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 11/24/2021 | Partial Approval | TROY SANDERS |
| Footing/Foundation/Slab | 12/10/2021 | Not Ready for Inspection | DAVID SCANTLIN |
| Excavation/Setback/Form/Re-Bar | 12/20/2021 | Approved | TROY SANDERS |
| Footing/Foundation/Slab | 12/20/2021 | Approved | TROY SANDERS |
| Deputy Reinf. Concrete | 12/22/2021 | Partial Approval | TROY SANDERS |
| Deputy Steel/Welding | 1/13/2022 | Conditional Approval | JUSTIN HAWLEY |
| Floor/Roof Diaphrgm/Shear Wall | 1/20/2022 | Partial Approval | TROY SANDERS |
| Green Building Rough | 1/20/2022 | Not Ready for Inspection | TROY SANDERS |
| MERV13>=Rough | 1/20/2022 | Not Ready for Inspection | TROY SANDERS |
| Verify Sprinkler Sign Off | 1/20/2022 | Not Ready for Inspection | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 2/11/2022 | Partial Approval | TROY SANDERS |
| Deputy Wood Construction | 3/15/2022 | Partial Approval | TROY SANDERS |
| BUILDING-Rough-Frame | 3/17/2022 | Partial Approval | TROY SANDERS |
| Green Building Rough | 3/17/2022 | Not Ready for Inspection | TROY SANDERS |
| MERV13>=Rough | 3/17/2022 | Approved | TROY SANDERS |
| Verify Sprinkler Sign Off | 3/17/2022 | Not Ready for Inspection | TROY SANDERS |
| ELECTRICAL-Final | 3/25/2022 | Approved | TROY SANDERS |
| HVAC-Rough | 3/25/2022 | Approved | TROY SANDERS |
| PLUMBING-Rough | 4/4/2022 | Approved | JEFFREY PARD |
| BUILDING-Rough-Frame | 4/8/2022 | Not Ready for Inspection | TROY SANDERS |
| Green Building Rough | 4/8/2022 | No Access for Inspection | TROY SANDERS |
| Verify Sprinkler Sign Off | 4/8/2022 | Not Ready for Inspection | TROY SANDERS |
| Interior/Exterior Lathing | 4/18/2022 | Not Ready for Inspection | KRISTEN CAUSEY |
| Drywall Nailing | 4/29/2022 | Approved | MORRIS JACKSON |
| Green Building Rough | 4/29/2022 | Approved | MORRIS JACKSON |
| Shower Pan | 5/9/2022 | Approved | TROY SANDERS |
| Sewer | 8/9/2022 | Approved | TROY SANDERS |
| ELECTRICAL-Final | 10/7/2022 | Approved | DAVID SCANTLIN |
| PLUMBING-Final | 10/7/2022 | Approved | DAVID SCANTLIN |
| HVAC-Final | 10/28/2022 | Approved | TROY SANDERS |
| BUILDING-Rough-Frame | 11/3/2022 | Approved | TROY SANDERS |
| Final | 11/3/2022 | OK to Issue CofO | TROY SANDERS |
| Green Building Final | 11/3/2022 | Approved | TROY SANDERS |
| MERV13>=Final | 11/3/2022 | Approved | TROY SANDERS |
| SGSOV-Seismic Gas S/O Valve | 11/3/2022 | SGSOV Approved | TROY SANDERS |
| Service/Power Release | 11/3/2022 | Approved | TROY SANDERS |
| Smoke Detectors | 11/3/2022 | Approved | TROY SANDERS |
| Verify Sprinkler Sign Off | 11/3/2022 | Approved | TROY SANDERS |