13994 W AZTEC ST 91342
Certificate Information: 13994 W AZTEC ST 91342
- Application / Permit
- 19010-20000-05317
- Plan Check / Job No.
- B19VN20676
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- NEW 30'0"X40'0" IRREGULAR SHAPED 1-STORY ACCESSORY DWELLING UNIT PER AB 494 AND SB 229
- Permit Issued
- Issued on 3/16/2020
- Issuing Office
- Valley
- Current Status
- CofO Issued on 12/25/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/26/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 12/5/2019 | MARVEL DELACRUZ |
| Corrections Issued | 12/8/2019 | MARVEL DELACRUZ |
| Quality Review Completed | 12/9/2019 | GUANG MIN TUNG |
| Building Plans Picked Up | 12/11/2019 | APPLICANT |
| Green Plans Picked Up | 12/11/2019 | APPLICANT |
| Plan Check Approved | 3/10/2020 | MARVEL DELACRUZ |
| Issued | 3/16/2020 | LADBS |
| CofO in Progress | 11/10/2021 | JOHN HAYES |
| Permit Finaled | 12/25/2021 | MICHAEL SMITH |
| CofO Issued | 12/25/2021 | MICHAEL SMITH |
| Permit Finaled | 12/25/2021 | MICHAEL SMITH |
Permit Application Clearance Information
| Address approval | Cleared | 3/2/2020 | GUILLERMO PETRA |
| Eng Process Fee Ord 176,300 | Cleared | 3/2/2020 | GUILLERMO PETRA |
| Low Impact Development | Cleared | 3/2/2020 | MITESH PATEL |
| Sewer availability | Cleared | 3/2/2020 | GUILLERMO PETRA |
| Roof/Waste drainage to street | Cleared | 3/9/2020 | MARKOS PEREZ-BRAN |
| Green Code | Cleared | 3/10/2020 | MICHAEL AYERS |
| Hydrant and Access approval | Cleared | 3/10/2020 | GEORGE SUCHAND |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Wassef,, Mena Maher Salama; Lic. No.: C84979 | 28131 VALERIO CT VALENCIA, CA 91354 |
Inspector Information
| KEVIN BERBERYAN, (818) 374-9931 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 4/8/2020 | Approved | TROY SANDERS |
| ELECTRICAL-Rough | 4/17/2020 | Partial Approval | TROY SANDERS |
| Footing/Foundation/Slab | 4/17/2020 | Approved | TROY SANDERS |
| Special/Order Compliance | 5/18/2020 | No Access for Inspection | TROY SANDERS |
| BUILDING-Rough-Frame | 7/14/2020 | Not Ready for Inspection | GREGG CUMMINGS |
| ELECTRICAL-Rough | 7/14/2020 | Approved | GREGG CUMMINGS |
| Green Building Rough | 7/14/2020 | Not Ready for Inspection | GREGG CUMMINGS |
| HVAC-Rough | 7/14/2020 | Not Ready for Inspection | GREGG CUMMINGS |
| PLUMBING-Rough | 7/14/2020 | Approved | GREGG CUMMINGS |
| Special/Order Compliance | 7/14/2020 | Partial Inspection | PIERRE VEGA |
| Verify Sprinkler Sign Off | 7/14/2020 | Approved | GREGG CUMMINGS |
| Special/Order Compliance | 7/24/2020 | No Access for Inspection | MISAEL ESPARZA |
| BUILDING-Rough-Frame | 8/17/2020 | Conditional Approval | MISAEL ESPARZA |
| Floor/Roof Diaphrgm/Shear Wall | 8/17/2020 | Approved | MISAEL ESPARZA |
| Green Building Rough | 8/17/2020 | Not Ready for Inspection | MISAEL ESPARZA |
| HVAC-Rough | 8/17/2020 | Approved | MISAEL ESPARZA |
| Insulation | 8/25/2020 | Conditional Approval | MISAEL ESPARZA |
| Insulation | 9/4/2020 | Corrections Issued | MISAEL ESPARZA |
| Drywall Nailing | 9/9/2020 | Not Ready for Inspection | MISAEL ESPARZA |
| Green Building Rough | 9/9/2020 | Approved | MISAEL ESPARZA |
| Interior/Exterior Lathing | 9/9/2020 | Not Ready for Inspection | MISAEL ESPARZA |
| PLUMBING-Rough | 9/18/2020 | Corrections Issued | MISAEL ESPARZA |
| Drywall Nailing | 9/23/2020 | Approved | JENNIFER RABUCHIN |
| Interior/Exterior Lathing | 9/23/2020 | Partial Approval | JENNIFER RABUCHIN |
| Shower Pan | 10/2/2020 | No Access for Inspection | MISAEL ESPARZA |
| Shower Pan | 10/16/2020 | Corrections Issued | MISAEL ESPARZA |
| Shower Pan | 10/28/2020 | Approved | MISAEL ESPARZA |
| Sewer | 12/15/2020 | Approved | MISAEL ESPARZA |
| Gas Test | 3/25/2021 | Approved | MISAEL ESPARZA |
| Green Building Final | 4/20/2021 | No Access for Inspection | MISAEL ESPARZA |
| BUILDING-Rough-Frame | 4/27/2021 | No Access for Inspection | MISAEL ESPARZA |
| Final | 4/27/2021 | No Access for Inspection | MISAEL ESPARZA |
| Green Building Final | 4/27/2021 | No Access for Inspection | MISAEL ESPARZA |
| SGSOV-Seismic Gas S/O Valve | 4/27/2021 | SGSOV Not Ready | MISAEL ESPARZA |
| Service/Power Release | 4/27/2021 | No Access for Inspection | MISAEL ESPARZA |
| Smoke Detectors | 4/27/2021 | No Access for Inspection | MISAEL ESPARZA |
| BUILDING-Rough-Frame | 10/15/2021 | Not Ready for Inspection | JOHN HAYES |
| ELECTRICAL-Final | 10/15/2021 | Not Ready for Inspection | JOHN HAYES |
| Final | 10/15/2021 | Corrections Issued | JOHN HAYES |
| Green Building Final | 10/15/2021 | Not Ready for Inspection | JOHN HAYES |
| HVAC-Final | 10/15/2021 | Not Ready for Inspection | JOHN HAYES |
| PLUMBING-Final | 10/15/2021 | Not Ready for Inspection | JOHN HAYES |
| SGSOV-Seismic Gas S/O Valve | 10/15/2021 | SGSOV Not Ready | JOHN HAYES |
| Service/Power Release | 10/15/2021 | Not Ready for Inspection | JOHN HAYES |
| Smoke Detectors | 10/15/2021 | Not Ready for Inspection | JOHN HAYES |
| BUILDING-Rough-Frame | 11/9/2021 | Approved | JOHN HAYES |
| ELECTRICAL-Final | 11/9/2021 | Approved | JOHN HAYES |
| Final | 11/9/2021 | OK to Issue CofO | JOHN HAYES |
| Green Building Final | 11/9/2021 | Approved | JOHN HAYES |
| HVAC-Final | 11/9/2021 | Approved | JOHN HAYES |
| PLUMBING-Final | 11/9/2021 | Approved | JOHN HAYES |
| SGSOV-Seismic Gas S/O Valve | 11/9/2021 | SGSOV Approved | JOHN HAYES |
| Service/Power Release | 11/9/2021 | Approved | JOHN HAYES |
| Smoke Detectors | 11/9/2021 | Approved | JOHN HAYES |
| Verify Rec and Parks Fee Memo | 11/9/2021 | Approved | JOHN HAYES |