15147 W LA MAIDA ST 91403

Certificate Information: 15147 W LA MAIDA ST 91403

Application / Permit
19010-20000-03667
Plan Check / Job No.
B19VN13817
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW 35' x 26'6" ACCESSORY DWELLING UNIT PER AB 494 AND SB 229. ALL WORK PER ENGINEERING
Permit Issued
Issued on 10/1/2019
Issuing Office
Valley
Current Status
CofO Issued on 8/16/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 8/16/2019 APPLICANT
Green Plans Picked Up 8/26/2019 APPLICANT
Assigned to Plan Check Engineer 8/29/2019 JEFFREY TANGONAN
Corrections Issued 9/4/2019 JEFFREY TANGONAN
Quality Review Completed 9/4/2019 STEVEN KIM
Building Plans Picked Up 9/5/2019 APPLICANT
Plan Check Approved 9/24/2019 JEFFREY TANGONAN
Issued 10/1/2019 LADBS
CofO in Progress 8/2/2023 MISAEL ESPARZA
Permit Finaled 8/16/2023 RUBEN SALAS
CofO Issued 8/16/2023 RUBEN SALAS
Permit Finaled 8/16/2023 RUBEN SALAS

Permit Application Clearance Information

Address approval Cleared 9/12/2019 GABRIEL ROBLES
Eng Process Fee Ord 176,300 Cleared 9/12/2019 GABRIEL ROBLES
Low Impact Development Cleared 9/12/2019 MARTIN FRAGOSO
Sewer availability Cleared 9/12/2019 GABRIEL ROBLES
Green Code Cleared 9/13/2019 MICHAEL AYERS
Roof/Waste drainage to street Cleared 9/24/2019 LEE GUILBEAUX

Contact Information

Contractor Owner-Builder       ,
Engineer Barakat,, Fouad Chafic; Lic. No.: C67449 8916 LONGDON AVE #C      TEMPLE CITY, CA 91780

Inspector Information

DAVID ANDERSON, (818) 374-1166 Office Hours: 7:00-8:00 AM MON-FRI
RAUL OLAGI, (818) 374-1166 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 11/6/2019 Partial Inspection RAUL BARAJAS
Excavation/Setback/Form/Re-Bar 12/18/2019 Not Ready for Inspection CHRISTOPHE COCHRAN
Excavation/Setback/Form/Re-Bar 1/10/2020 Not Ready for Inspection CHRISTOPHE COCHRAN
Underground Mechanical 1/10/2020 Approved CHRISTOPHE COCHRAN
Excavation/Setback/Form/Re-Bar 1/17/2020 Approved CHRISTOPHE COCHRAN
Footing/Foundation/Slab 1/17/2020 Approved CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 2/7/2020 Partial Approval CHRISTOPHE COCHRAN
Sewer 2/13/2020 Not Ready for Inspection CHRISTOPHE COCHRAN
Sewer 2/20/2020 Approved CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 3/4/2020 Corrections Issued CHRISTOPHE COCHRAN
Green Building Rough 3/4/2020 Not Ready for Inspection CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 3/6/2020 Partial Approval CHRISTOPHE COCHRAN
HVAC-Rough 3/6/2020 Approved CHRISTOPHE COCHRAN
ELECTRICAL-Rough 3/9/2020 Not Ready for Inspection CHRISTOPHE COCHRAN
PLUMBING-Rough 3/12/2020 Not Ready for Inspection CHRISTOPHE COCHRAN
Interior/Exterior Lathing 3/13/2020 Not Ready for Inspection CHRISTOPHE COCHRAN
PLUMBING-Rough 3/13/2020 Corrections Issued CHRISTOPHE COCHRAN
PLUMBING-Rough 3/17/2020 Not Ready for Inspection CHRISTOPHE COCHRAN
BUILDING-Rough-Frame 3/18/2020 Partial Approval CHRISTOPHE COCHRAN
ELECTRICAL-Rough 3/18/2020 Approved CHRISTOPHE COCHRAN
Interior/Exterior Lathing 3/18/2020 Partial Approval CHRISTOPHE COCHRAN
PLUMBING-Rough 3/18/2020 Approved CHRISTOPHE COCHRAN
ELECTRICAL-Rough 3/20/2020 Partial Approval CHRISTOPHE COCHRAN
Insulation 3/20/2020 Approved CHRISTOPHE COCHRAN
Underground Mechanical 3/20/2020 Approved CHRISTOPHE COCHRAN
Service/Power Release 3/24/2020 Corrections Issued DANIEL ORRANTE
Drywall Nailing 3/25/2020 Approved CHARLES POWELL
Green Building Rough 3/25/2020 Approved CHARLES POWELL
Special/Order Compliance 4/28/2020 Approved DANIEL ORRANTE
Service/Power Release 6/12/2020 Not Ready for Inspection THOMAS FINNILA
ELECTRICAL-Final 7/17/2020 Approved CHARLES POWELL
Green Building Final 7/17/2020 Approved CHARLES POWELL
HVAC-Final 7/17/2020 Approved CHARLES POWELL
PLUMBING-Final 7/17/2020 Corrections Issued CHARLES POWELL
Service/Power Release 7/17/2020 Not Ready for Inspection CHARLES POWELL
BUILDING-Rough-Frame 7/28/2020 No Access for Inspection CHARLES POWELL
ELECTRICAL-Final 7/28/2020 No Access for Inspection CHARLES POWELL
Final 7/28/2020 No Access for Inspection CHARLES POWELL
HVAC-Final 7/28/2020 No Access for Inspection CHARLES POWELL
MERV13>=Final 7/28/2020 No Access for Inspection CHARLES POWELL
MERV13>=Rough 7/28/2020 No Access for Inspection CHARLES POWELL
PLUMBING-Final 7/28/2020 No Access for Inspection CHARLES POWELL
SGSOV-Seismic Gas S/O Valve 7/28/2020 SGSOV Not Ready CHARLES POWELL
Service/Power Release 7/28/2020 No Access for Inspection CHARLES POWELL
Smoke Detectors 7/28/2020 No Access for Inspection CHARLES POWELL
Verify Sprinkler Sign Off 7/28/2020 No Access for Inspection CHARLES POWELL
BUILDING-Rough-Frame 12/4/2020 Approved CHARLES POWELL
Final 12/4/2020 Not Ready for Inspection CHARLES POWELL
MERV13>=Final 12/4/2020 Approved CHARLES POWELL
MERV13>=Rough 12/4/2020 Approved CHARLES POWELL
SGSOV-Seismic Gas S/O Valve 12/4/2020 SGSOV Approved CHARLES POWELL
Service/Power Release 12/4/2020 Not Ready for Inspection CHARLES POWELL
Smoke Detectors 12/4/2020 Approved CHARLES POWELL
Verify Sprinkler Sign Off 12/4/2020 Approved CHARLES POWELL
Final 7/7/2022 Corrections Issued JACK KARGODORIAN
Service/Power Release 7/7/2022 Not Ready for Inspection JACK KARGODORIAN
Final 7/28/2023 Not Ready for Inspection MISAEL ESPARZA
Service/Power Release 7/28/2023 Not Ready for Inspection MISAEL ESPARZA
ELECTRICAL-Final 8/1/2023 Approved MISAEL ESPARZA
Final 8/2/2023 OK to Issue CofO MISAEL ESPARZA
Service/Power Release 8/2/2023 Approved MISAEL ESPARZA