18239 W MARGATE ST 91356

Certificate Information: 18239 W MARGATE ST 91356

Application / Permit
19010-20000-01504
Plan Check / Job No.
B19VN05924
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW 27'-3" X 62'-0" IRREGULAR DETACHED ACCESSORY DWELLING UNIT PER AB 494 AND SB 229. ALL WORK PER ENGINEERING.
Permit Issued
Issued on 2/4/2020
Issuing Office
Valley
Current Status
CofO Issued on 11/10/2020
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 4/12/2019 APPLICANT
Assigned to Plan Check Engineer 4/25/2019 JENNIFER LEE
Green Plans Picked Up 4/25/2019 APPLICANT
Corrections Issued 5/1/2019 JENNIFER LEE
Quality Review Completed 5/1/2019 STEVEN KIM
Building Plans Picked Up 5/2/2019 APPLICANT
Plan Check Approved 11/5/2019 JENNIFER LEE
Issued 2/4/2020 LADBS
CofO in Progress 11/10/2020 DAVID SANDOVAL
CofO Issued 11/10/2020 MICHAEL SMITH
Permit Finaled 11/10/2020 MICHAEL SMITH

Permit Application Clearance Information

Green Code Cleared 6/10/2019 PARISA ZAHABI
Address approval Cleared 7/17/2019 LEE GUILBEAUX
Eng Process Fee Ord 176,300 Cleared 7/17/2019 LEE GUILBEAUX
Sewer availability Cleared 7/24/2019 GUILLERMO PETRA
Construction near power lines Cleared 8/30/2019 RIDWAN HARDY
Low Impact Development Cleared 9/25/2019 RYAN HUDSON
Hydrant and Access approval Cleared 11/1/2019 GEORGE SUCHAND
Roof/Waste drainage to street Cleared 11/1/2019 ADRIAN CASTRO

Contact Information

Contractor Owner-Builder       ,
Engineer Sayah,, Daniel Hoshyar; Lic. No.: C67905 15233 VENTURA BLVD STE 1130      SHERMAN OAKS, CA 91403

Inspector Information

JOHN KIDWELL, (818) 774-4314 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 5/11/2020 Corrections Issued DAVID SANDOVAL
PLUMBING-Rough 5/14/2020 Partial Approval DAVID SANDOVAL
Sewer 5/14/2020 Approved DAVID SANDOVAL
Excavation/Setback/Form/Re-Bar 5/28/2020 Not Ready for Inspection DAVID SANDOVAL
Footing/Foundation/Slab 5/28/2020 Corrections Issued DAVID SANDOVAL
Excavation/Setback/Form/Re-Bar 6/2/2020 Approved DAVID SANDOVAL
Footing/Foundation/Slab 6/2/2020 Approved DAVID SANDOVAL
BUILDING-Rough-Frame 7/28/2020 Not Ready for Inspection DAVID SANDOVAL
ELECTRICAL-Rough 7/28/2020 Approved DAVID SANDOVAL
Floor/Roof Diaphrgm/Shear Wall 7/28/2020 Partial Approval DAVID SANDOVAL
HVAC-Rough 7/28/2020 Corrections Issued DAVID SANDOVAL
MERV13>=Rough 7/28/2020 Not Ready for Inspection DAVID SANDOVAL
Verify Sprinkler Sign Off 7/28/2020 Approved DAVID SANDOVAL
Floor/Roof Diaphrgm/Shear Wall 7/30/2020 Approved DAVID SANDOVAL
HVAC-Rough 7/30/2020 Approved DAVID SANDOVAL
BUILDING-Rough-Frame 8/7/2020 Approved DAVID SANDOVAL
Green Building Rough 8/7/2020 Approved DAVID SANDOVAL
Insulation 8/7/2020 Approved DAVID SANDOVAL
MERV13>=Rough 8/7/2020 Approved DAVID SANDOVAL
Drywall Nailing 8/14/2020 Approved DAVID SANDOVAL
Interior/Exterior Lathing 8/14/2020 Partial Approval DAVID SANDOVAL
Interior/Exterior Lathing 8/24/2020 Approved DAVID SANDOVAL
Final 9/30/2020 Corrections Issued DAVID SANDOVAL
Green Building Final 9/30/2020 Not Ready for Inspection DAVID SANDOVAL
MERV13>=Final 9/30/2020 Not Ready for Inspection DAVID SANDOVAL
SGSOV-Seismic Gas S/O Valve 9/30/2020 SGSOV Not Ready DAVID SANDOVAL
Service/Power Release 9/30/2020 Not Ready for Inspection DAVID SANDOVAL
Smoke Detectors 9/30/2020 Approved DAVID SANDOVAL
Final 11/9/2020 OK to Issue CofO DAVID SANDOVAL
Green Building Final 11/9/2020 Approved DAVID SANDOVAL
MERV13>=Final 11/9/2020 Approved DAVID SANDOVAL
SGSOV-Seismic Gas S/O Valve 11/9/2020 SGSOV Approved DAVID SANDOVAL
Service/Power Release 11/9/2020 Approved DAVID SANDOVAL