1332 N LAUREL WAY 90210
Certificate Information: 1332 N LAUREL WAY 90210
- Application / Permit
- 18047-20000-02104
- Plan Check / Job No.
- B18VN19549
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- (N) 83'4"X71'92" IRREGULAR SHAPED POOL & 12'3"X12'4" SPA ON PILES.
- Permit Issued
- Issued on 1/28/2019
- Issuing Office
- Valley
- Current Status
- CofO Issued on 4/6/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/13/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 11/20/2018 | MARVEL DELACRUZ |
| Corrections Issued | 11/25/2018 | MARVEL DELACRUZ |
| Quality Review Completed | 11/29/2018 | STEVEN KIM |
| Building Plans Picked Up | 11/30/2018 | APPLICANT |
| Plan Check Approved | 1/11/2019 | MARVEL DELACRUZ |
| Issued | 1/28/2019 | LADBS |
| CofO in Progress | 4/5/2022 | MICHAEL PELHAM |
| Permit Finaled | 4/6/2022 | DANIEL ORRANTE |
| CofO Issued | 4/6/2022 | DANIEL ORRANTE |
| Permit Finaled | 4/6/2022 | DANIEL ORRANTE |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Saljooghi,, Sanjar; Lic. No.: C53610 | 23265 PARK ENSENADA CALABASAS, CA 91302 |
| Engineer | Su,, Yu-Ting; Lic. No.: C76714 | 28 SAGE LAKE FOREST, CA 92630 |
| Geologist | Carrle,, Conrad Henry; Lic. No.: EG2359 | 23128 WILDWOOD ROAD NEWHALL, CA 91321 |
Inspector Information
| CARLOS MATAMOROS, (310) 914-3878 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Piling/Pier/Caisson | 10/17/2019 | Not Ready for Inspection | CARLOS MATAMOROS |
| Deputy Steel/Welding | 10/18/2019 | Corrections Issued | CARLOS MATAMOROS |
| Excavation/Setback/Form/Re-Bar | 10/18/2019 | Corrections Issued | CARLOS MATAMOROS |
| Piling/Pier/Caisson | 10/21/2019 | Partial Approval | CARLOS MATAMOROS |
| Deputy Other (see comments) | 11/8/2019 | Conditional Approval | CARLOS MATAMOROS |
| Excavation/Setback/Form/Re-Bar | 11/26/2019 | Partial Approval | DAVID FEILER |
| Deputy Other (see comments) | 12/2/2019 | Conditional Approval | CARLOS MATAMOROS |
| Pool Piping | 3/18/2020 | Not Ready for Inspection | ANTHONY MCDOWALL |
| Pre-Gunite | 3/18/2020 | Corrections Issued | ANTHONY MCDOWALL |
| Pre-Gunite | 3/26/2020 | Corrections Issued | ANTHONY MCDOWALL |
| Pre-Gunite | 4/27/2020 | Not Ready for Inspection | ANTHONY MCDOWALL |
| Pre-Gunite | 5/28/2020 | Approved | ANTHONY MCDOWALL |
| Pool Equipment Noise Test | 7/13/2020 | Not Ready for Inspection | ROBERT CHAVEZ |
| Pre-Inspection | 7/20/2020 | Partial Inspection | ANTHONY MCDOWALL |
| Enclosure/Fence | 6/9/2021 | Approved | ANTHONY MCDOWALL |
| Excavation/Setback/Form/Re-Bar | 12/21/2021 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Final | 12/21/2021 | Corrections Issued | GERMAN RODRIGUEZ MENDOZA |
| SGSOV-Seismic Gas S/O Valve | 12/21/2021 | SGSOV Approved | GERMAN RODRIGUEZ MENDOZA |
| Special/Order Compliance | 12/22/2021 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Final | 4/5/2022 | Conditional Approval | MICHAEL PELHAM |