3445 S VINTON AVE 90034

Certificate Information: 3445 S VINTON AVE 90034

Application / Permit
18016-10000-40678
Plan Check / Job No.
B18LA27383
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT-STORY RETROFIT PER LABC CHAPTER 93. (2) STEEL CANTILIVER COLUMN SYSTEM WORK IS DONE AT SIDE ELEVATIONS 1 & 2 TUCK-UNDER PARKING AREAS AT FIRST FLOOR.
Permit Issued
Issued on 12/28/2020
Issuing Office
Current Status
CofC Issued on 4/29/2021

Permit Application Status History

Submitted 12/20/2018 APPLICANT
Assigned to Plan Check Engineer 1/31/2019 ALFREDO JARA
Corrections Issued 2/5/2019 ALFREDO JARA
Quality Review Completed 2/8/2019 SAI KHUM
Building Plans Picked Up 2/12/2019 APPLICANT
Plan Check Approved 2/28/2019 ALFREDO JARA
Issued 12/28/2020 APPLICANT
OK for CofC 4/28/2021 GRANT WOODS
CofC Issued 4/29/2021 TED RIES

Permit Application Clearance Information

Housing rent stabilization Cleared 12/24/2020 STEVEN HOFSTAD

Contact Information

Contractor Cal Retrofit; Lic. No.: 1022167-B 6900 CANBY AVE #108      RESEDA, CA 91335
Engineer Zohrevand,, Pedram; Lic. No.: C82328 21201 KITTRIDGE ST APT 9105      WOODLAND HILLS, CA 91303

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 1/13/2021 Approved GRANT WOODS
Deputy Other (see comments) 2/23/2021 Conditional Approval GRANT WOODS
Footing/Foundation/Slab 2/24/2021 Approved GRANT WOODS
Structural Steel Frame 2/24/2021 Approved GRANT WOODS
Wood Frame 2/24/2021 Approved GRANT WOODS
Deputy Other (see comments) 3/8/2021 Conditional Approval GRANT WOODS
Interior/Exterior Lathing 4/1/2021 Approved GRANT WOODS
Final 4/28/2021 OK for CofC GRANT WOODS
SGSOV-Seismic Gas S/O Valve 4/28/2021 SGSOV Approved GRANT WOODS
Smoke Detectors 4/28/2021 Approved GRANT WOODS