14912 W DICKENS ST 91403
Certificate Information: 14912 W DICKENS ST 91403
- Application / Permit
- 18016-10000-37299
- Plan Check / Job No.
- B18LA24785
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (35) Condo-Multi Family
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH. 93 USING 4 NEW SCCS.
- Permit Issued
- Issued on 4/16/2020
- Issuing Office
- Current Status
- CofC Issued on 3/18/2021
Permit Application Status History
| Submitted | 11/16/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 12/27/2018 | VARAND SARKISIAN |
| Corrections Issued | 1/2/2019 | VARAND SARKISIAN |
| Quality Review Completed | 1/2/2019 | HANS SANTIAGO |
| Building Plans Picked Up | 1/15/2019 | APPLICANT |
| Plan Check Approved | 2/19/2019 | VARAND SARKISIAN |
| Issued | 4/16/2020 | APPLICANT |
| OK for CofC | 2/22/2021 | KENNETH ROBERTS |
| CofC Issued | 3/18/2021 | RICKEY JACKSON |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 4/9/2020 | CHARLES GARCIA |
Contact Information
| Contractor | Optimum Seismic Inc; Lic. No.: 1012702-B | 5508 S SANTA FE AVENUE VERNON, CA 90058 |
| Engineer | Mirmohammadsadeghi,, Kamaleddin; Lic. No.: C53468 | 1377 S BEVERLY GLEN BLVD 308 LOS ANGELES, CA 90024 |
Inspector Information
| BRIAN KELLY, (818) 374-1127 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 5/27/2020 | Partial Inspection | DANIEL VARNUM |
| Deputy Steel/Welding | 6/18/2020 | Conditional Approval | DANIEL VARNUM |
| Deputy Drilled-In Anchors | 6/23/2020 | Conditional Approval | BRUCE CAMPBELL |
| Deputy Steel/Welding | 6/24/2020 | Conditional Approval | DANIEL VARNUM |
| Footing/Foundation/Slab | 6/24/2020 | Not Ready for Inspection | DANIEL VARNUM |
| Footing/Foundation/Slab | 6/25/2020 | Approved | DANIEL VARNUM |
| Deputy Reinf. Concrete | 6/26/2020 | Conditional Approval | DANIEL VARNUM |
| Structural Steel Frame | 6/26/2020 | Approved | DANIEL VARNUM |
| Wood Frame | 6/26/2020 | Approved | DANIEL VARNUM |
| Interior/Exterior Lathing | 7/8/2020 | Approved | DANIEL VARNUM |
| Final | 1/28/2021 | Partial Approval | DANIEL VARNUM |
| SGSOV-Seismic Gas S/O Valve | 1/28/2021 | SGSOV Approved | DANIEL VARNUM |
| Smoke Detectors | 1/28/2021 | Approved | DANIEL VARNUM |
| Final | 2/22/2021 | OK for CofC | KENNETH ROBERTS |