3731 S MENTONE AVE 90034
Certificate Information: 3731 S MENTONE AVE 90034
- Application / Permit
- 18016-10000-32755
- Plan Check / Job No.
- B18LA21611
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CHAPTER 93. INSTALL (N) SCCS
- Permit Issued
- Issued on 8/5/2020
- Issuing Office
- Current Status
- CofC Issued on 4/1/2022
Permit Application Status History
| Submitted | 10/9/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 11/8/2018 | SAMUEL GONZALEZ |
| Corrections Issued | 11/14/2018 | SAMUEL GONZALEZ |
| Quality Review Completed | 11/16/2018 | SAI KHUM |
| Building Plans Picked Up | 11/30/2018 | APPLICANT |
| Plan Check Approved | 6/27/2019 | SAMUEL GONZALEZ |
| Issued | 8/5/2020 | APPLICANT |
| OK for CofC | 3/30/2022 | GRANT WOODS |
| CofC Issued | 4/1/2022 | DAVID TSAU |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 8/5/2020 | PHILLIP MUNGUIA |
Contact Information
| Contractor | Optimum Seismic Inc; Lic. No.: 1012702-B | 5508 S SANTA FE AVENUE VERNON, CA 90058 |
| Engineer | Park,, Kenan; Lic. No.: C86314 | 904 S HARVARD BLVD APT 208 LOS ANGELES, CA 90006 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 8/14/2020 | Approved | PAUL DAVIDSON |
| Deputy Drilled-In Anchors | 9/8/2020 | Conditional Approval | PAUL DAVIDSON |
| Deputy Reinf. Concrete | 9/8/2020 | Conditional Approval | PAUL DAVIDSON |
| Footing/Foundation/Slab | 9/18/2020 | Approved | GRANT WOODS |
| Structural Steel Frame | 9/18/2020 | Approved | GRANT WOODS |
| Wood Frame | 9/18/2020 | Approved | GRANT WOODS |
| Deputy Reinf. Concrete | 9/24/2020 | Conditional Approval | JONATHAN QUACH |
| Interior/Exterior Lathing | 10/9/2020 | Approved | RUSSELL BONVOULOIR |
| Final | 12/22/2020 | Corrections Issued | GRANT WOODS |
| METHANE-Final | 12/22/2020 | Approved | GRANT WOODS |
| SGSOV-Seismic Gas S/O Valve | 12/22/2020 | SGSOV Not Ready | GRANT WOODS |
| Smoke Detectors | 12/22/2020 | Not Ready for Inspection | GRANT WOODS |
| Final | 3/30/2022 | OK for CofC | GRANT WOODS |
| SGSOV-Seismic Gas S/O Valve | 3/30/2022 | SGSOV Approved | GRANT WOODS |
| Smoke Detectors | 3/30/2022 | Approved | GRANT WOODS |