2101 E CHARLOTTE ST 90033
Certificate Information: 2101 E CHARLOTTE ST 90033
- Application / Permit
- 18016-10000-29395
- Plan Check / Job No.
- B18LA19415
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT PER LABC CHAPTER 93 USING STEEL ORDINARY MOMENT FRAME.
- Permit Issued
- Issued on 1/14/2020
- Issuing Office
- Metro
- Current Status
- CofC Issued on 7/2/2020
Permit Application Status History
| Submitted | 9/11/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 10/24/2018 | TEODORO DIAZ RODRIGUEZ |
| Corrections Issued | 11/1/2018 | TEODORO DIAZ RODRIGUEZ |
| Quality Review Completed | 11/5/2018 | SAI KHUM |
| Building Plans Picked Up | 11/9/2018 | APPLICANT |
| Plan Check Approved | 1/2/2019 | TEODORO DIAZ RODRIGUEZ |
| Issued | 1/14/2020 | LADBS |
| OK for CofC | 6/26/2020 | MARK FERRARI |
| CofC Issued | 7/2/2020 | ERNESTO CORRAL |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 1/6/2020 | ISMAEL HERNANDEZ |
Contact Information
| Contractor | Sks Construction; Lic. No.: 720390-B | 5104 GARDEN GROVE AVE TARZANA, CA 91356 |
| Engineer | Albert, Samama; Lic. No.: C43288 | , |
Inspector Information
| DARRYL ARNOLD, (213) 482-0341 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 1/31/2020 | Approved | MARK FERRARI |
| Deputy Steel/Welding | 4/3/2020 | Conditional Approval | MARK FERRARI |
| Wood Frame | 4/3/2020 | Corrections Issued | MARK FERRARI |
| Wood Frame | 4/20/2020 | Partial Approval | MARK FERRARI |
| Deputy Steel/Welding | 4/21/2020 | Conditional Approval | MARK FERRARI |
| Deputy Steel/Welding | 4/28/2020 | Conditional Approval | MARK FERRARI |
| Deputy Steel/Welding | 4/29/2020 | Conditional Approval | MARK FERRARI |
| Deputy Drilled-In Anchors | 5/4/2020 | Conditional Approval | MARK FERRARI |
| Floor/Roof Diaphrgm/Shear Wall | 5/5/2020 | Conditional Approval | MARK FERRARI |
| Footing/Foundation/Slab | 5/5/2020 | Corrections Issued | MARK FERRARI |
| Structural Steel Frame | 5/5/2020 | Not Ready for Inspection | MARK FERRARI |
| Wood Frame | 5/5/2020 | Conditional Approval | MARK FERRARI |
| Footing/Foundation/Slab | 5/12/2020 | Approved | MARK FERRARI |
| Structural Steel Frame | 5/12/2020 | Approved | MARK FERRARI |
| Wood Frame | 5/12/2020 | Approved | MARK FERRARI |
| Deputy Reinf. Concrete | 5/13/2020 | Conditional Approval | MARK FERRARI |
| Deputy Steel/Welding | 5/13/2020 | Conditional Approval | MARK FERRARI |
| Interior/Exterior Lathing | 5/20/2020 | Corrections Issued | MARK FERRARI |
| Final | 6/26/2020 | OK for CofC | MARK FERRARI |
| SGSOV-Seismic Gas S/O Valve | 6/26/2020 | SGSOV Approved | MARK FERRARI |
| Smoke Detectors | 6/26/2020 | Approved | MARK FERRARI |