2515 W 21ST ST 90018
Certificate Information: 2515 W 21ST ST 90018
- Application / Permit
- 18016-10000-27740
- Plan Check / Job No.
- B18LA18221
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH 93. REMOVE 2 COLUMNS AND REPLACE WITH 2 SCCS.
- Permit Issued
- Issued on 11/9/2020
- Issuing Office
- Current Status
- CofC Issued on 5/11/2021
Permit Application Status History
| Submitted | 8/28/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 10/11/2018 | JOHN FRANCIA |
| Corrections Issued | 10/15/2018 | JOHN FRANCIA |
| Quality Review Completed | 10/18/2018 | SAI KHUM |
| Building Plans Picked Up | 10/19/2018 | APPLICANT |
| Plan Check Approved | 11/2/2018 | JOHN FRANCIA |
| Issued | 11/9/2020 | APPLICANT |
| OK for CofC | 4/22/2021 | DARRYL ARNOLD |
| CofC Issued | 5/11/2021 | ERNESTO CORRAL |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 10/8/2020 | STEVEN HOFSTAD |
Contact Information
| Contractor | Omega Structural Inc; Lic. No.: 998075-B | 4269 S HARVARD BOULEVARD LOS ANGELES, CA 90062 |
| Engineer | Maalouf,, Sami; Lic. No.: C53210 | 15445 VENTURA BLVD STE 367 SHERMAN OAKS, CA 91403 |
Inspector Information
| DARRYL ARNOLD, (213) 482-0341 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 11/24/2020 | Conditional Approval | DARRYL ARNOLD |
| Deputy Other (see comments) | 1/15/2021 | Conditional Approval | ERNESTO CORRAL |
| Footing/Foundation/Slab | 1/29/2021 | Not Ready for Inspection | JONATHAN QUACH |
| Excavation/Setback/Form/Re-Bar | 2/2/2021 | Corrections Issued | MARK FERRARI |
| Excavation/Setback/Form/Re-Bar | 2/23/2021 | Not Ready for Inspection | DARRYL ARNOLD |
| Footing/Foundation/Slab | 2/23/2021 | Approved | DARRYL ARNOLD |
| Wood Frame | 3/8/2021 | Not Ready for Inspection | DARRYL ARNOLD |
| Wood Frame | 3/9/2021 | Approved | DARRYL ARNOLD |
| Interior/Exterior Lathing | 3/17/2021 | Approved | DARRYL ARNOLD |
| Final | 4/22/2021 | OK for CofC | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 4/22/2021 | SGSOV Approved | DARRYL ARNOLD |
| Smoke Detectors | 4/22/2021 | Approved | DARRYL ARNOLD |