15120 W VANOWEN ST 91405
Certificate Information: 15120 W VANOWEN ST 91405
- Application / Permit
- 18016-10000-24921
- Plan Check / Job No.
- B18LA16188
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH 93. 18 NEW SCCS. (no change in parking)
- Permit Issued
- Issued on 1/30/2020
- Issuing Office
- Metro
- Current Status
- CofC Issued on 3/18/2022
Permit Application Status History
| Submitted | 8/3/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 9/13/2018 | MINA HABIB |
| Corrections Issued | 9/15/2018 | MINA HABIB |
| Quality Review Completed | 9/20/2018 | SAI KHUM |
| Building Plans Picked Up | 9/28/2018 | APPLICANT |
| Plan Check Approved | 10/22/2018 | MINA HABIB |
| Issued | 1/30/2020 | LADBS |
| OK for CofC | 2/3/2022 | KENNETH ROBERTS |
| CofC Issued | 3/18/2022 | HENRY BAGHDASSARIAN |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 12/4/2018 | STEVEN HOFSTAD |
Contact Information
| Contractor | J N N General Construction Inc; Lic. No.: 1030534-B | 14751 ERWIN ST #17 VAN NUYS, CA 91411 |
| Engineer | , ; Lic. No.: C53080 | 21500 WYANDOTTE ST 106 CANOGA PARK, CA 91303 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 10/22/2021 | Approved | KENNETH ROBERTS |
| Pre-Inspection | 10/22/2021 | Approved | KENNETH ROBERTS |
| Excavation/Setback/Form/Re-Bar | 11/30/2021 | Approved | KENNETH ROBERTS |
| Structural Steel Frame | 11/30/2021 | Partial Approval | KENNETH ROBERTS |
| Wood Frame | 11/30/2021 | Partial Approval | KENNETH ROBERTS |
| Deputy Wood Construction | 12/1/2021 | Conditional Approval | KENNETH ROBERTS |
| Insulation | 12/7/2021 | Approved | KENNETH ROBERTS |
| Floor/Roof Diaphrgm/Shear Wall | 12/17/2021 | Approved | KENNETH ROBERTS |
| Deputy Wood Construction | 12/20/2021 | Conditional Approval | KENNETH ROBERTS |
| Interior/Exterior Lathing | 1/13/2022 | Approved | KENNETH ROBERTS |
| SGSOV-Seismic Gas S/O Valve | 1/20/2022 | SGSOV Not Ready | KENNETH ROBERTS |
| Final | 2/3/2022 | OK for CofC | KENNETH ROBERTS |
| SGSOV-Seismic Gas S/O Valve | 2/3/2022 | SGSOV Approved | KENNETH ROBERTS |
| Smoke Detectors | 2/3/2022 | Approved | KENNETH ROBERTS |