12731 W CASWELL AVE 90066
Certificate Information: 12731 W CASWELL AVE 90066
- Application / Permit
- 18016-10000-21138
- Plan Check / Job No.
- B18LA13457
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH. 93. INSTALL MOMENT FRAME AND CANTILEVERED COLUMNS
- Permit Issued
- Issued on 8/24/2021
- Issuing Office
- Current Status
- CofC Issued on 12/15/2021
- Certificate of Occupancy
- CofC Issued More Information
Permit Application Status History
| Submitted | 7/2/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 8/16/2018 | ANA AVELAR |
| Corrections Issued | 8/20/2018 | ANA AVELAR |
| Quality Review Completed | 8/21/2018 | SAI KHUM |
| Building Plans Picked Up | 8/23/2018 | APPLICANT |
| Plan Check Approved | 10/1/2018 | ANA AVELAR |
| Issued | 8/24/2021 | APPLICANT |
| OK for CofC | 12/8/2021 | GRANT WOODS |
| CofC Issued | 12/15/2021 | DAVID TSAU |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 8/24/2021 | PHILLIP MUNGUIA |
Contact Information
| Contractor | Optimum Seismic Inc; Lic. No.: 1012702-A | 5508 S SANTA FE AVENUE VERNON, CA 90058 |
| Engineer | Mirmohammadsadeghi, Kamaleddin; Lic. No.: C53468 | 1377 S BEVERLY GLEN BLVD 308 LOS ANGELES, CA 90024 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 9/21/2021 | Corrections Issued | JOEY BUCHANAN |
| Deputy Steel/Welding | 9/28/2021 | Conditional Approval | GRANT WOODS |
| Insulation | 9/28/2021 | Not Ready for Inspection | GRANT WOODS |
| Wood Frame | 9/28/2021 | Not Ready for Inspection | GRANT WOODS |
| Wood Frame | 9/29/2021 | Partial Approval | PAUL DAVIDSON |
| Deputy Wood Construction | 9/30/2021 | Conditional Approval | GRANT WOODS |
| Deputy Steel/Welding | 10/7/2021 | Conditional Approval | GRANT WOODS |
| Footing/Foundation/Slab | 10/8/2021 | Partial Approval | GRANT WOODS |
| Structural Steel Frame | 10/8/2021 | Not Ready for Inspection | GRANT WOODS |
| Wood Frame | 10/8/2021 | Partial Approval | GRANT WOODS |
| Footing/Foundation/Slab | 11/3/2021 | Approved | GRANT WOODS |
| Structural Steel Frame | 11/3/2021 | Approved | GRANT WOODS |
| Wood Frame | 11/3/2021 | Approved | GRANT WOODS |
| Deputy Reinf. Concrete | 11/8/2021 | Conditional Approval | GRANT WOODS |
| Interior/Exterior Lathing | 11/17/2021 | Approved | JOHN DODGE |
| Final | 12/8/2021 | OK for CofC | GRANT WOODS |
| SGSOV-Seismic Gas S/O Valve | 12/8/2021 | SGSOV Approved | GRANT WOODS |
| Smoke Detectors | 12/8/2021 | Approved | GRANT WOODS |