115 N NORMANDIE AVE 90004
Certificate Information: 115 N NORMANDIE AVE 90004
- Application / Permit
- 18016-10000-20902
- Plan Check / Job No.
- B18LA13316
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT-STORY SEISMIC RETROFIT PER LAMC DIV. 93: INSTALL STEEL MOMENT FRAME AND PLYWOOD SHEARWALL
- Permit Issued
- Issued on 6/23/2021
- Issuing Office
- Current Status
- CofC Issued on 11/15/2022
Permit Application Status History
| Submitted | 6/29/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 8/1/2018 | MANUEL MONTUFAR |
| Corrections Issued | 8/7/2018 | MANUEL MONTUFAR |
| Quality Review Completed | 8/8/2018 | CELESTE MORRIS |
| Applicant returned to address corrections | 10/18/2018 | MANUEL MONTUFAR |
| Applicant returned to address corrections | 1/3/2019 | MANUEL MONTUFAR |
| Plan Check Approved | 1/4/2019 | MANUEL MONTUFAR |
| Plan Check Approved | 5/19/2021 | MANUEL MONTUFAR |
| Issued | 6/23/2021 | APPLICANT |
| OK for CofC | 11/15/2022 | DARRYL ARNOLD |
| CofC Issued | 11/15/2022 | WINSTON DUNNING |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 6/21/2021 | PHILLIP MUNGUIA |
Contact Information
| Architect | Santillan,, Michael; Lic. No.: C23337 | 832 SANTIAGO ROAD COSTA MESA, CA 92626 |
| Contractor | Saunders Construction Inc; Lic. No.: 616856-B | 1760 MONROVIA AVE SUITE A-1 COSTA MESA, CA 92627 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 7/14/2021 | Approved | BRUCE CAMPBELL |
| Deputy Drilled-In Anchors | 7/26/2021 | Conditional Approval | BRUCE CAMPBELL |
| Excavation/Setback/Form/Re-Bar | 7/27/2021 | Approved | BRUCE CAMPBELL |
| Footing/Foundation/Slab | 7/27/2021 | Approved | BRUCE CAMPBELL |
| Structural Steel Frame | 7/27/2021 | Approved | BRUCE CAMPBELL |
| Wall Anchors | 7/27/2021 | Approved | BRUCE CAMPBELL |
| Deputy Reinf. Concrete | 7/28/2021 | Conditional Approval | BRUCE CAMPBELL |
| Deputy Wood Construction | 7/29/2021 | Conditional Approval | BRUCE CAMPBELL |
| Floor/Roof Diaphrgm/Shear Wall | 7/29/2021 | Approved | BRUCE CAMPBELL |
| Interior/Exterior Lathing | 8/4/2021 | Approved | BRUCE CAMPBELL |
| Final | 8/11/2021 | Corrections Issued | BRUCE CAMPBELL |
| SGSOV-Seismic Gas S/O Valve | 8/11/2021 | SGSOV Not Ready | BRUCE CAMPBELL |
| Smoke Detectors | 8/11/2021 | Approved | BRUCE CAMPBELL |
| Final | 11/15/2022 | OK for CofC | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 11/15/2022 | SGSOV Approved | DARRYL ARNOLD |