6626 N HAYVENHURST AVE 91406
Certificate Information: 6626 N HAYVENHURST AVE 91406
- Application / Permit
- 18016-10000-17157
- Plan Check / Job No.
- B18LA10718
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY SEISMIC RETROFIT AS PER LABC CHAPTER 93.- ADDING (2) BAY ORDINARY MOMENT FRAMES
- Permit Issued
- Issued on 11/9/2020
- Issuing Office
- Current Status
- CofC Issued on 4/26/2021
Permit Application Status History
| Submitted | 5/30/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 7/12/2018 | MONICA RAMIREZ |
| Corrections Issued | 7/26/2018 | MONICA RAMIREZ |
| Quality Review Completed | 7/26/2018 | SAI KHUM |
| Building Plans Picked Up | 8/1/2018 | APPLICANT |
| Applicant returned to address corrections | 9/25/2018 | MONICA RAMIREZ |
| Plan Check Approved | 9/26/2018 | MONICA RAMIREZ |
| Issued | 11/9/2020 | APPLICANT |
| OK for CofC | 3/22/2021 | KENNETH ROBERTS |
| CofC Issued | 4/26/2021 | RICKEY JACKSON |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 10/19/2020 | STEVEN HOFSTAD |
Contact Information
| Contractor | Titan Contracting Services Inc; Lic. No.: 976552-B | 13434 RAYMER STREET NORTH HOLLYWOOD, CA 91605 |
| Engineer | Ni,, Zhang Yuan; Lic. No.: C68149 | 743 S SIERRA VISTA AVE C ALHAMBRA, CA 91801 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 12/3/2020 | Partial Inspection | DANIEL VARNUM |
| Deputy Drilled-In Anchors | 12/22/2020 | Conditional Approval | BRUCE CAMPBELL |
| Footing/Foundation/Slab | 12/24/2020 | Approved | DANIEL VARNUM |
| Deputy Reinf. Concrete | 12/29/2020 | Conditional Approval | BRUCE CAMPBELL |
| Deputy Other (see comments) | 12/30/2020 | Conditional Approval | DANIEL VARNUM |
| Deputy Shotcrete | 12/30/2020 | Conditional Approval | DANIEL VARNUM |
| Deputy Steel/Welding | 1/13/2021 | Conditional Approval | DANIEL VARNUM |
| Deputy Steel/Welding | 1/15/2021 | Conditional Approval | JEFFREY FULTON |
| Structural Steel Frame | 1/22/2021 | Approved | DANIEL VARNUM |
| Wood Frame | 1/22/2021 | Approved | DANIEL VARNUM |
| Interior/Exterior Lathing | 2/1/2021 | Approved | HAMID PISHEHVAR |
| Final | 2/12/2021 | Not Ready for Inspection | DANIEL VARNUM |
| SGSOV-Seismic Gas S/O Valve | 2/12/2021 | SGSOV Not Ready | DANIEL VARNUM |
| Smoke Detectors | 2/12/2021 | Approved | DANIEL VARNUM |
| Final | 3/9/2021 | Not Ready for Inspection | JOHN KITCKO |
| SGSOV-Seismic Gas S/O Valve | 3/9/2021 | SGSOV Approved | JOHN KITCKO |
| Final | 3/10/2021 | Partial Approval | DANIEL VARNUM |
| Insulation | 3/10/2021 | Approved | DANIEL VARNUM |
| Final | 3/22/2021 | OK for CofC | KENNETH ROBERTS |