1756 S MALCOLM AVE 90024

Certificate Information: 1756 S MALCOLM AVE 90024

Application / Permit
18016-10000-05271
Plan Check / Job No.
B18LA03272
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT AS PER LAMC DIVISION 93. INSTALL (N) SCCS
Permit Issued
Issued on 5/14/2020
Issuing Office
Metro
Current Status
CofC Issued on 8/31/2020

Permit Application Status History

Submitted 2/20/2018 APPLICANT
Assigned to Plan Check Engineer 2/22/2018 ALBERT SERVIN
Corrections Issued 2/27/2018 ALBERT SERVIN
Quality Review Completed 2/27/2018 SAI KHUM
Building Plans Picked Up 2/28/2018 APPLICANT
Plan Check Approved 3/16/2018 ALBERT SERVIN
Issued 5/14/2020 LADBS
OK for CofC 8/25/2020 PAUL DAVIDSON
CofC Issued 8/31/2020 TED RIES

Permit Application Clearance Information

Specific Plan Cleared 3/19/2018 ZURIEL ESPINOSA
Supp. Use District POD/CDO/TDO Cleared 3/19/2018 ZURIEL ESPINOSA
Housing rent stabilization Cleared 2/13/2020 MICHAEL GREGERSON

Contact Information

Contractor Owner-Builder       ,
Engineer , ; Lic. No.: C68626       ,

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 5/22/2020 Approved JEFF BYTHEWAY
Deputy Steel/Welding 6/2/2020 Conditional Approval GRANT WOODS
Deputy Drilled-In Anchors 6/15/2020 Conditional Approval PAUL DAVIDSON
Deputy Steel/Welding 6/15/2020 Conditional Approval PAUL DAVIDSON
Deputy Drilled-In Anchors 6/16/2020 Conditional Approval GRANT WOODS
Excavation/Setback/Form/Re-Bar 6/18/2020 Not Ready for Inspection PAUL DAVIDSON
Footing/Foundation/Slab 6/18/2020 Not Ready for Inspection PAUL DAVIDSON
Insulation 6/18/2020 Not Ready for Inspection PAUL DAVIDSON
Smoke Detectors 6/18/2020 Not Ready for Inspection PAUL DAVIDSON
Structural Steel Frame 6/18/2020 Not Ready for Inspection PAUL DAVIDSON
Wood Frame 6/18/2020 Not Ready for Inspection PAUL DAVIDSON
Excavation/Setback/Form/Re-Bar 6/19/2020 No Access for Inspection GRANT WOODS
Footing/Foundation/Slab 6/19/2020 No Access for Inspection GRANT WOODS
Insulation 6/19/2020 No Access for Inspection GRANT WOODS
Structural Steel Frame 6/19/2020 No Access for Inspection GRANT WOODS
Wood Frame 6/19/2020 No Access for Inspection GRANT WOODS
Excavation/Setback/Form/Re-Bar 7/6/2020 Approved PAUL DAVIDSON
Footing/Foundation/Slab 7/6/2020 Approved PAUL DAVIDSON
Insulation 7/6/2020 Approved PAUL DAVIDSON
Structural Steel Frame 7/6/2020 Not Ready for Inspection PAUL DAVIDSON
Wood Frame 7/6/2020 Not Ready for Inspection PAUL DAVIDSON
Structural Steel Frame 7/10/2020 Conditional Approval PAUL DAVIDSON
Wood Frame 7/10/2020 Approved PAUL DAVIDSON
Interior/Exterior Lathing 7/15/2020 Approved GRANT WOODS
METHANE-Final 7/20/2020 Approved PAUL DAVIDSON
SGSOV-Seismic Gas S/O Valve 7/20/2020 SGSOV Not Ready PAUL DAVIDSON
SGSOV-Seismic Gas S/O Valve 7/24/2020 SGSOV Not Ready PAUL DAVIDSON
SGSOV-Seismic Gas S/O Valve 8/4/2020 SGSOV Not Ready PAUL DAVIDSON
SGSOV-Seismic Gas S/O Valve 8/6/2020 SGSOV Not Ready PAUL DAVIDSON
Final 8/18/2020 Corrections Issued JOHN DODGE
SGSOV-Seismic Gas S/O Valve 8/18/2020 SGSOV Not Ready JOHN DODGE
Smoke Detectors 8/18/2020 Approved JOHN DODGE
Final 8/25/2020 OK for CofC PAUL DAVIDSON
SGSOV-Seismic Gas S/O Valve 8/25/2020 SGSOV Approved PAUL DAVIDSON