3620 S GRAND VIEW BLVD 90066

Certificate Information: 3620 S GRAND VIEW BLVD 90066

Application / Permit
18014-30000-02897
Plan Check / Job No.
B18WL03392
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
1st and 2nd story additions to (e) 1-story s.f.d.
Permit Issued
Issued on 3/3/2020
Issuing Office
West Los Angeles
Current Status
CofO Issued on 8/12/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 5/25/2018 APPLICANT
Green Plans Picked Up 6/11/2018 APPLICANT
Assigned to Plan Check Engineer 6/21/2018 KAVIAN REFAHI
Corrections Issued 6/25/2018 KAVIAN REFAHI
Quality Review Completed 6/27/2018 TARIK SAOUD
Building Plans Picked Up 7/2/2018 APPLICANT
Plan Check Approved 3/3/2020 KAVIAN REFAHI
Issued 3/3/2020 LADBS
CofO in Progress 8/15/2024 JESUS PINEDA
No Progress 8/29/2024 KENNETH NAGLE
CofO in Progress 8/29/2024 KENNETH NAGLE
Permit Finaled 8/12/2025 RICHARD STEINBACH
CofO Issued 8/12/2025 RICHARD STEINBACH
Permit Finaled 8/12/2025 RICHARD STEINBACH

Permit Application Clearance Information

GPI Written Notices Cleared 6/26/2018 KAVIAN REFAHI
Grading Pre-Inspection Cleared 6/26/2018 KAVIAN REFAHI
Low Impact Development Cleared 11/14/2019 RYAN HUDSON
Eng Process Fee Ord 176,300 Cleared 11/25/2019 DENNIS BRAGIN
Roof/Waste drainage to street Cleared 11/25/2019 DENNIS BRAGIN
Sewer availability Cleared 11/25/2019 DENNIS BRAGIN
Green Code Cleared 2/26/2020 DONALD CRICHLOW

Contact Information

Contractor Hufnagel Construction; Lic. No.: 537446-B 12543 WOODGREEN STREET      LOS ANGELES, CA 90066
Engineer Almalla, Dean; Lic. No.: C58024 15053 VENTURA BLVD STE 205      SHERMAN OAKS, CA 91403

Inspector Information

KIRK SANDERS, (310) 914-3896 Office Hours: 7:00-8:00 AM MON-FRI
ARAM AVEDISIAN, (310) 914-3896 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 4/6/2020 Corrections Issued GERMAN RODRIGUEZ MENDOZA
Excavation/Setback/Form/Re-Bar 4/13/2020 Partial Approval GERMAN RODRIGUEZ MENDOZA
Footing/Foundation/Slab 7/16/2020 Conditional Approval JUSTIN CURTIS
Footing/Foundation/Slab 7/21/2020 Conditional Approval JUSTIN CURTIS
PLUMBING-Rough 8/14/2020 Partial Approval OGANES TARAKHCHYAN
Floor/Roof Diaphrgm/Shear Wall 8/17/2020 Partial Approval OGANES TARAKHCHYAN
Wood Frame 8/17/2020 Partial Approval OGANES TARAKHCHYAN
Floor/Roof Diaphrgm/Shear Wall 8/21/2020 Partial Approval EVAN COOPER
Floor/Roof Diaphrgm/Shear Wall 9/8/2020 Partial Approval OGANES TARAKHCHYAN
Floor/Roof Diaphrgm/Shear Wall 10/8/2020 Partial Approval EVAN COOPER
Deputy Wood Construction 11/6/2020 Conditional Approval KEVIN SARGSYAN
Interior/Exterior Lathing 11/30/2020 Not Ready for Inspection OGANES TARAKHCHYAN
Floor/Roof Diaphrgm/Shear Wall 12/18/2020 Approved RICHARD ROBLES
HVAC-Rough 12/24/2020 Corrections Issued RICHARD ROBLES
PLUMBING-Rough 12/24/2020 Not Ready for Inspection RICHARD ROBLES
PLUMBING-Rough 12/31/2020 Approved EVAN COOPER
Footing/Foundation/Slab 1/11/2021 Not Ready for Inspection OGANES TARAKHCHYAN
HVAC-Rough 1/11/2021 Partial Approval OGANES TARAKHCHYAN
Underground Mechanical 2/5/2021 Approved RICHARD ROBLES
ELECTRICAL-Rough 2/19/2021 Approved RICHARD ROBLES
BUILDING-Rough-Frame 3/1/2021 Corrections Issued RICHARD ROBLES
Green Building Rough 3/1/2021 Approved RICHARD ROBLES
Insulation 3/1/2021 Approved RICHARD ROBLES
Drywall Nailing 3/5/2021 Approved RICHARD ROBLES
Interior/Exterior Lathing 3/5/2021 Partial Approval RICHARD ROBLES
Interior/Exterior Lathing 4/23/2021 Approved EVAN COOPER
Service/Power Release 11/12/2021 Not Ready for Inspection JOHNNY MIRANDA
BUILDING-Rough-Frame 11/23/2021 Not Ready for Inspection JOHNNY MIRANDA
Final 11/23/2021 Not Ready for Inspection JOHNNY MIRANDA
Footing/Foundation/Slab 11/23/2021 Not Ready for Inspection JOHNNY MIRANDA
Green Building Final 11/23/2021 Not Ready for Inspection JOHNNY MIRANDA
SGSOV-Seismic Gas S/O Valve 11/23/2021 SGSOV Not Ready JOHNNY MIRANDA
Smoke Detectors 11/23/2021 Not Ready for Inspection JOHNNY MIRANDA
Gas Test 12/7/2021 Corrections Issued JOHNNY MIRANDA
Gas Test 12/8/2021 Approved JOHNNY MIRANDA
SGSOV-Seismic Gas S/O Valve 12/8/2021 SGSOV Approved JOHNNY MIRANDA
Service/Power Release 2/17/2023 Not Ready for Inspection JOHNNY MIRANDA
BUILDING-Rough-Frame 6/14/2023 Approved JOHNNY MIRANDA
Final 6/14/2023 Corrections Issued JOHNNY MIRANDA
Footing/Foundation/Slab 6/14/2023 Approved JOHNNY MIRANDA
Green Building Final 6/14/2023 Approved JOHNNY MIRANDA
Smoke Detectors 6/14/2023 Approved JOHNNY MIRANDA
Final 6/15/2023 Corrections Issued JOHNNY MIRANDA
ELECTRICAL-Final 10/10/2023 Approved JESUS PINEDA
HVAC-Final 10/10/2023 Approved JESUS PINEDA
Service/Power Release 10/10/2023 Not Ready for Inspection JESUS PINEDA
PLUMBING-Final 6/5/2024 Approved JESUS PINEDA
Final 7/22/2024 Conditional Approval KENNETH NAGLE
Final 8/13/2024 OK to Issue CofO JESUS PINEDA
Service/Power Release 8/13/2024 Approved JESUS PINEDA
Special/Order Compliance 8/29/2024 Corrections Issued KENNETH NAGLE